background image

P/N:  L340136 
REV:  8.2.10 
 
 
Merco, LLC 
1111 North Hadley Road 
Fort Wayne, Indiana  46804 
Telephone:  260.459.8200 
Fax:   888.790.8193 
Technical Support:  800.678.9511 
mercosavory.com 

PARTS & SERVICE MANUAL 

 

Insta-Therm 

16000 Series 

Содержание Insta-Therm 16000 Series

Страница 1: ...0136 REV 8 2 10 Merco LLC 1111 North Hadley Road Fort Wayne Indiana 46804 Telephone 260 459 8200 Fax 888 790 8193 Technical Support 800 678 9511 mercosavory com PARTS SERVICE MANUAL Insta Therm 16000...

Страница 2: ...s Amps Watts Hz Phase Cord Plug Weight 16001 208 11 25 2340 60 Single 6 NEMA 6 20P 47 lbs 21 3 kg 16003 230 9 91 2280 50 Single CEE 7 7 47 lbs 21 3 kg 16005 208 11 25 2340 60 Single 6 NEMA 6 20P 47 lb...

Страница 3: ...Insta Therm Service Manual 3 SCHEMATIC MODEL 16001...

Страница 4: ...Insta Therm Service Manual 4 SCHEMATIC MODEL 16003 16005...

Страница 5: ...through the high limit thermostat Also to the open contacts of the main power relay HEATING CIRCUIT Closing the main power switch feeds power to the cooling fan and the coil of the main power relay I...

Страница 6: ...replace as needed No Stand By Heat Elements Check the amp draw on each element for proper load Check specification plate for rating information Check individual elements for opens shorts and proper r...

Страница 7: ...Insta Therm Service Manual 7 This page intentionally left blank...

Страница 8: ...D 340180 Cordset 240V 20A w sleeve sp E 340032 Bushing Heyco F 340117 Hi Limit G 340033 Contact Coil H 369331 Finger Guard I 369378 Fan Motor J 340036 Solid State Relay K 340037 Terminal Block X3 L 2...

Страница 9: ...Insta Therm Service Manual 9 EXPLODED VIEW ILLUSTRATION...

Страница 10: ...support bracket in place and remove the bracket Retain the screws for later reinstallation Leave the right hand side heater support bracket in place CAUTION Heater elements must not be handled with ba...

Страница 11: ...ght hand wall of the unit feeding the lead wires through the hole in the left hand wall and heater support bracket The small diameter of the ceramic end caps on the element should fit snuggly into the...

Страница 12: ...the heater element feeding the lead wires through the holes Secure using the screws previously removed STEP 5 CONNECT THE LEFT SIDE HEATER WIRES Connect all four 4 heater wires on the left side to the...

Страница 13: ...to the terminal block as shown Heater wire 1 and 2 are connected to terminal block position 3 heater wire 3 to terminal block position 2 and heater wire 4 to terminal block position 1 STEP 7 REINSTAL...

Страница 14: ...Insta Therm Service Manual 14 This page intentionally left blank...

Страница 15: ...Insta Therm Service Manual 15 This page intentionally left blank...

Страница 16: ...Insta Therm Service Manual 16...

Отзывы: