background image

MHC-1 Service Manual 

 

 

5

TROUBLESHOOTING GUIDE (CONT’D) 

 

 

 

 

Display reads 
unusual characters 

 

Make sure wires are connected properly 
(grounded). 

 

 

If wires are grounded properly, new control board 
is needed. 

 

 

 

On/Off switch doesn’t 
light (but unit works 
properly) 

Power Switch 

Check wiring to switch. 

 
HEAT SHELF – REPLACEMENT  

 

1.  

Disconnect 

power.

 

2.   Take out screws holding “L Brackets” in cavity.

 

3.   Disconnect thermocouple and all power connections to board.  Mark all wires for reassembly.

 

4.   Take out power board.

 

5.   Take out shelf mounting screws from both sides.

 

6.   Remove shelves and feed wiring out of unit.

 

 
 

 
 
 

 

7.    Reassemble in reverse order. 

 
 

CONTROL BOARD – REPLACEMENT 

 

 
1.  Remove four (4) screws. 
2.  Disconnect ribbon cable. 
3. Remove 

board. 

4.  Reassemble in reverse order. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

  

   WARNING: 

 

Be careful to avoid tearing the aluminum foil while working with wire 
connections. 

!

!

 

When replacing U.I. board, be sure ribbon 

cable is connected so that blue wire is 
facing towards interior of unit. 

Содержание 86007

Страница 1: ...of America Technical Support Hotline 800 678 9511 Telephone 260 459 8200 www mercosavory com parts service manual This document includes sequence of operations troubleshooting replacement instructions...

Страница 2: ...MHC 1 Service Manual 2 UNIT SPECIFICATIONS Model Voltage Amps Watts Hz Phase Plug 86007 Left Side Control 120 VAC 3 360 60 1 6 NEMA 5 15P 86009 Right Side Control 120 VAC 3 360 60 1 6 NEMA 5 15P...

Страница 3: ...tor is ground Power is permanently supplied to the main power switch Heating Circuit Closing the main power switch supplies voltage to the power board and control board The control is set to the desir...

Страница 4: ...g information If the amp draw is high or low check the individual elements for opens shorts and proper resistance WITH POWER OFF To check resistance of the elements remove all leads from the elements...

Страница 5: ...vity 3 Disconnect thermocouple and all power connections to board Mark all wires for reassembly 4 Take out power board 5 Take out shelf mounting screws from both sides 6 Remove shelves and feed wiring...

Страница 6: ...340004 Rear Retention Rod I 340001 Heater Insulation Plate J 340013 Hex Washer K 340012 Top Bottom Insulation L 340011 Leg M 340014 E Style External Retaining Ring N 340015 Plastic Tray O 340016 Fron...

Страница 7: ...MHC 1 Service Manual 7 EXPLODED VIEW MODEL 86007...

Страница 8: ...troller I 340007 Side Cover Panel J 340008 Ribbon Cable Subassembly K 340009 System Controller L 340010 Control Panel Label M 340011 Leg N 340012 Top Bottom Insulation O 340013 Hex Washer P 340014 E S...

Страница 9: ...MHC 1 Service Manual 9 EXPLODED VIEW MODEL 86009...

Страница 10: ...erning Menu and Product programming please refer to MHC 1 Operator Manual Temperature Button Time Button Top Heating Element Indicator Light Green Indicator Light Green Up Arrow Button Down Arrow Butt...

Страница 11: ...MHC 1 Service Manual 11 WIRING DIAGRAM...

Страница 12: ...MHC 1 Service Manual 12...

Отзывы: