Product Ordering Information

The mA700 can be purchased with different power 

supply cords to accomodate a variety of locations. 

Purchase products online at 

SigmaAldrich.com/products

.

Model

Description

Catalog 

Number

mA700 

Essential 

Power 

Supply

mA700 Power Supply with cord for 

the US, Canada, and locations 

using NEMA 5-15P (YP12) plugs

MA700-US

mA700 Power Supply with cord for 

France, Germany, and locations 

using CEE 7/7 (YP22) plugs 

MA700-EU

mA700 Power Supply with cord for 

the UK, Ireland and locations using 

type G (YP61) plugs 

MA700-UK

mA700 Power Supply with cord for 

Japan and locations using YP18 

plugs 

MA700-NI

mA700 Power Supply with cord for 

China and locations using Type I 

(YP03) plugs 

MA700-ZH

Also available

mA400 

Basic 

Power 

Supply

mA400 Power Supply with cord for 

the US, Canada, and locations 

using NEMA 5-15P (YP12) plugs

MA400-US

mA400 Power Supply with cord for 

France, Germany, and locations 

using CEE 7/7 (YP22) plugs

MA400-EU

mA400 Power Supply with cord for 

the UK, Ireland, and locations 

using type G (YP61) plugs

MA400-UK

mA400 Power Supply with cord for 

Japan and locations using YP18 

plugs

MA400-NI

mA400 Power Supply with cord for 

China and locations using Type 1 

(YP03) plugs

MA400-ZH

Support

Notice

We provide information and advice to our customers 

on application technologies and regulatory matters 

to the best of our knowledge and ability, but without 

obligation or liability. Existing laws and regulations are 

to be observed in all cases by our customers. This also 

applies in respect to any rights of third parties. Our 

information and advice do not relieve our customers of 

their own responsibility for checking the suitability of 

our products for the envisaged purpose.
The information in this document is subject to change 

without notice and should not be construed as a 

commitment by the manufacturing or selling entity, or 

an affiliate. We assume no responsibility for any errors 

that may appear in this document.

Contact Information

For the location of the office nearest you, go to 

SigmaAldrich.com/offices

.

Legal Manufacturer

EMD Millipore Corporation 

400 Summit Drive, Burlington, MA, USA

Technical Assistance

Visit the tech service page on our web site at 

SigmaAldrich.com/techservice

.

Standard Warranty

The applicable warranty for the products listed in this 

publication may be found at 

SigmaAldrich.com/terms

.

Содержание Millipore mA700

Страница 1: ...er Constant voltages constant currents and constant power Four terminal outlets LCD display Timer with alarm function Advanced safety devices Stackable Wide applications for DNA RNA and protein electrophoresis User Guide mA700 Essential Power Supply mA700 Introduction 1 Equipment Operation 2 Symbols Used on Device Regulatory Warnings Safety Precautions Environmental Operating Conditions Avoiding E...

Страница 2: ...carefully before operating this equipment Do not alter the equipment Failure to follow these directions could result in personal and or laboratory hazards as well as invalidate equipment warranty Use a properly grounded electrical outlet with correct voltage and current handling capacity Disconnect from power supply before maintenance and servicing Refer servicing to qualified personnel Never use ...

Страница 3: ...erate the power supplies in high humidity environments 95 or where condensation may occur 7 To avoid condensation after operating the power supply in a cold room wrap the unit in a plastic bag and allow at least 2 hours for the unit to equilibrate to room temperature before removing the bag and operating the unit 8 Prior to applying any cleaning or decontamination methods other than manufacturer s...

Страница 4: ...jack 4 Power ON the unit by pressing the ON Off switch on the back Operating Instructions Control Interface LED Indicator Indicates running conditions Button Functions Key Descriptions Icon Function Start Stop Press to activate or stop the unit Pause Press to temporarily interrupt power to an operation in progress resume power after pausing without resetting the timer Page Toggle Press to go back ...

Страница 5: ...ower supply will constantly operate until the user manually ends the run Constant Mode Operation 1 Press the Start Stop key to start operation The LED is lit and the screen will show real time parameter values When parameter reaches the set value its color will turn orange 2 Press the Toggle key to switch the display between real time value and set value page Note When a run is completed operation...

Страница 6: ...Press the Start Stop key to start operation The LED is lit and the screen will show real time parameter values When parameters reach the set value the color will turn orange 2 Press the Toggle key to switch the display between real time value and set value page Note When a run is completed operation stops with an alarm and COMPLETE is displayed on the screen 3 Press the Start Stop key to terminate...

Страница 7: ...blown Replace the fuse Fuse broken repeatedly Hardware failure Contact our Technical Service Department Operation stops and the screen displays PLC ERROR Communication wires on circuit board have loosened or broke We recommend that you send the machine back to your local distributor or our Technical Service Department for maintenance Operation stops with alarm The screen displays NO LOAD Electroph...

Страница 8: ... with alarm Display shows LEAKAGE Ground leak detected during run Check the electrophoresis system for improper grounding Restart the power supply by turning the Power switch off and on Operation stops with alarm Display shows OVER TEMPERATURE Power supply is overheating Turn off power supply Check for sufficient airflow around the power supply fan After cooling down restart the power supply by tu...

Страница 9: ...ower Supply with cord for France Germany and locations using CEE 7 7 YP22 plugs MA400 EU mA400 Power Supply with cord for the UK Ireland and locations using type G YP61 plugs MA400 UK mA400 Power Supply with cord for Japan and locations using YP18 plugs MA400 NI mA400 Power Supply with cord for China and locations using Type 1 YP03 plugs MA400 ZH Support Notice We provide information and advice to...