P 11
Step 1
5
5
12x40mm screws
Place floor on firm and level base, ensure
base has suitable drainage free from areas
where water can collect. (See front page on
base requirements).
Attach the floors using 12 x 40mm screws
40mm
screw
Pre drill
hole
Fix the corners with 50mm
screws as shown in diagram.
Position the panels so there is equal spacing
between the floor and cladding on all 4 sides
Step 2
2
3
3x50mm Screws
50mm
screw
Pre drill
hole
Step 3
Fix the remaining plain side and
a window side at the corners
with 50mm screws as shown in
diagram.
4
3
6x50mm Screws
50mm
screw
Pre drill
hole
Step 4
Fix the remaining window side
and the door gable at the
corners with 50mm screws as
shown in diagram.
4
1
9x50mm Screws
50mm
screw
Pre drill
hole
Содержание 01PTOSBA1008DDFW-V2
Страница 10: ...P 18 ...