After the smart Wallbox Home has been properly taken into operation, replace the housing cover and lock
it into place: This is described in step 12 above.
PLEASE NOTE!
To finalize the process of taking the Wallbox into operation, the maximum charge current setting of
the power supply must be checked inside the Wallbox and adjusted if required using the coded rotary
switch. In order to perform a final check of the functioning of the Wallbox, the contactor of the Wallbox
must be checked in test mode for correct functioning. Test mode is described in the next section.
Setup and test modes.
If no vehicle is available for taking the Wallbox into operation or for testing it, you can check the func-
tioning of the smart Wallbox Home (contactor, CP and RCD tripping) using test mode. You can also alter
the factory setting for the maximum charging current of the smart Wallbox Home in setup mode using the
coded rotary switch if the charge current made available by the domestic power supply differs from this
preset value. However, the rated current indicated on the product label must not be exceeded under any
circumstances.
The electronic components module of the smart Wallbox
Home provides access to the coded rotary switch, which
is factory preset to the
0
position, through the opening on
the left hand side.
For test and setup mode, you can set the coded rota-
ry switch to one of the values indicated on the cover
around the opening using the VDE blade screwdriver (0.5
x 2.5 mm). You can find an explanation of these values in
section „Settings for the coded rotary switch.“ on page
18.
In order to adjust the settings using the coded rotary
switch, you must remove the housing cover and, depen-
ding on the working step, remove or replace the electronic
components cover (see steps 5 and 6 described on page
13 in section „Mechanical and electrical installation.“).
DANGER!
After opening the electronic components cover, dangerous voltages may be present on the inside of the
Wallbox as well as on components you are able to touch. ALWAYS switch off the MCB in the domestic po-
wer supply and the internal RCCB of the Wallbox before you continue in setup or test mode.
Always observe the 5 golden rules of electrical installation:
1. Cut off all voltage sources
2. Secure all cut-off devices
3. Verify absence of voltage
4. Ground and short-circuit
5. Cover or bar access to adjacent components under voltage
Otherwise, there is a risk of severe or even fatal injury through electric shock!