21
OPERATION AND STORAGE
TO TURN ON THE HEATER
1. Turn on the valve on the gas supply cylinder completely
2. Press and turn the variable control knob to PILOT position (counter-clockwise 90°).
3. Press down the variable control knob and hold for 90 seconds. While holdiing down the variable
control knob,press the igniter button several times until the pilot flame lights. Release the variable
control knob after the pilot flame lights.
Note:
If a new tank has just been connected,please allow at least one minute for the air in the gas
pipeline to purge out through the pilot hole.
When lighting the pilot flame make sure that the variable control knob is continuously press down
while pressing the igniter button. Variable control knob can be released after the pilot flame lights.
Pilot flame can be watched and checked from the small round window with sliding lid located at
the bottom of the flame screen (to the left or right side of the controller).
If the pilot flame does not light or it goes out,repeat step 3.
4. After the pilot flame lights,turn the variable control knob to maximum position and leave it there for 5
minutes or more beforing turning the knob to desired temperature position.
TO TURN OFF THE HEATER
1. Turn the variable control knob to PILOT position.
2. Press and turn teh variable control knob to OFF position.
Storage
1. Always close the gas valve of the gas cylinder after use or in case of disturbance.
2. Remove the pressure controller and the hose.
3. Check the tightness of the gas valve and for damage. If you suspect a damage,have it changed
by your gas dealer.
4.
Never store liquid gas cylinder in a sub-terrian,or at places without adequate air ventilation.
OFF: The heater stop work.
HIGH: Maximum temperature position
LOW: Minimum temperature position