Menvier Security TSD402 Скачать руководство пользователя страница 5

Acknowledgement

Options

-

The TSD402 may be programmed to stop dialling after the first call

has been acknowledged or when two, or three have been

acknowledged. The acknowledgement may also be disabled

altogether, when the speech dialler is used in this mode it dials the first

telephone number and providing the call is answered it plays the

message and shuts down. If the call is not answered it dials the second

telephone number.

Aborting a Call

-

If the system is accidentally triggered the speech dialler is

automatically  shut down when a valid user passcode is entered.

Operator Controls and Display

3

TSD402 User Manual

Overview

16 Character LCD
Display

Tactile Rubber
Keypad

User 1 Functions
Printed Under Each
Key

Part-Set (HOME) key

Full Set (AWAY) key

UNSET

1

B ELL TEST

2

WA LK TES T

3

4

U SE R COD E 1

5

C HI ME

6

U SER C ODE 2

7

H OME AR EA

8

D IA LLER

9

E VEN T LOG

HO ME

0

AWAY

Intelligent Security & Fire Ltd

Содержание TSD402

Страница 1: ...larm Control Panel Speech Dialler User Manual UNSET TSD402 1 BELL TEST 2 WALK TEST 3 4 USER CODE1 5 CHIME 6 USER CODE2 7 HOME AREA 8 DIALLER 9 EVENT LOG HOME 0 AWAY I n t e l l i g e n t S e c u r i t...

Страница 2: ...Zones 8 User Options Introduction 9 Bell Test 10 Walk Test 11 Change Passcode 1 12 Change Chime Zones 12 Change Passcode 2 13 Home Area Configuration 14 Speech Dialler Programming 15 View Event Log 24...

Страница 3: ...asscode followed by the AWAY key To part set the system they simply enter the first 2 digits of their passcode followed by the HOME key When unsetting the system the user must enter all 4 digits of th...

Страница 4: ...of recording time available for phrases and each phrase can be any length as long as the total does not exceed 60 seconds For example the Common Phrase may be 12 seconds Phrase F 5 seconds Phrase P 8...

Страница 5: ...own If the call is not answered it dials the second telephone number Aborting a Call If the system is accidentally triggered the speech dialler is automatically shut down when a valid user passcode is...

Страница 6: ...our system to set using the Final Exit zone normally the front door The display will show USE F E ROUTE and the system will set when the Final Exit zone is opened then closed 4 Operating the System TS...

Страница 7: ...rs and the count down entry timer is re started If at the end of the second count down the system has not been unset a full alarm condition will occur internal external sounders and speech dialler act...

Страница 8: ...methods User Reset This allows the users to reset the system following an alarm activation Engineer Reset This requires an engineer to attend site and reset your system following an alarm activation...

Страница 9: ...passcode again e g 5 6 7 8 RESET CODE 6846 Write down the 4 digit number Telephone the alarm company and quote the number You will be asked to report the circumstances of the alarm If an engineer is...

Страница 10: ...ing the Quick Chime setting procedure as shown below 8 Operating the System TSD402 User Manual UNSET Enter CH Quick Chime Setting The display shows the zones that are programmed as Chime None in the a...

Страница 11: ...the structure of the User Options menu When a function is selected and completed the system will return to the unset condition 9 TSD402 User Manual User Options UNSET Enter first 3 digits of Passcode...

Страница 12: ...n the remaining on time 10 User Options TSD402 User Manual UNSET Enter first 3 digits of Passcode then e g 567 USEROPTION Press 1 for Bell Test Bell Test SnDr BELL STB 9 Press to advance test or to ab...

Страница 13: ...r Options UNSET Enter first 3 digits of Passcode then e g 5 6 7 USER OPTION Press 2 for Walk Test Walk Test NONE Activate each zone in turn No Zones Active CF 1 2 3 4 5 F T As each zone is activated t...

Страница 14: ...u the procedure for changing Chime zones is the same as the Quick Chime procedure described on page 8 12 User Options TSD402 User Manual UNSET Enter first 3 digits of Passcode then e g 5 6 7 USER OPTI...

Страница 15: ...sscode then e g 5 6 7 USER OPTION Press 6 for Passcode 2 Change Passcode 2 PASSCODE 2 Enter new pascode e g 7 8 9 0 PASSCODE 2 7890 Press to accept UNSET A two sound indicates acceptance a single low...

Страница 16: ...st 3 digits of Passcode then e g 5 6 7 USER OPTION Press 7 for Home Area Home Area U7 O A A A A A Zone 1 2 3 4 5 F Exit When the display shows the required setting press to accept UNSET The display sh...

Страница 17: ...Tel No 2 Press 3 for Tel No 3 Press 0 for Common Phrase Press 7 for Fire Phrase Press 8 for PA Phrase Press 9 for Alarm Phrase Press for Last Call Log UNSET Enter Passcode to return to Unset PLAYING...

Страница 18: ...uire a pause after the pre fixed digit before dialling the telephone number When entering telephone numbers it is possible to insert a 3 second pause if required The functionality of the key changes w...

Страница 19: ...ows required number press for 3 seconds to enter READY P0811234567 Press short press T Press short press Tone Dialling Selected P Press short press Pulse Dialling Selected READY Press Inserting a Paus...

Страница 20: ...ed and have a blank message recorded This is achieved by selecting the relevant phrase and pressing to start the recording process and then pressing immediately to stop the recording process If any of...

Страница 21: ...calling them and getting them to press their 8 button If a series of clicks is heard or the tone cannot be sustained by holding down the button then a Tone Dialling Simulator will be needed to succes...

Страница 22: ...display will show NO REPLY then the unit will re dial the number The unit plays common phrase Name Address then the selected phrase Fire PA or Alarm At the end of the selected phrase the person receiv...

Страница 23: ...2 User Manual User Options Test Activation READY Select the message to be sent then press the key SENDING A To No 1 e g press 9 then to send the Alarm message PLAYING PHRASE 0 PLAYING PHRASE A RINGING...

Страница 24: ...LEARED BY ALL 3 The TSD402 will clear down when the call is acknowledged by all three recipients CLEARED BY NO 1 The TSD402 will clear down when the call is answered by any of the three recipients i e...

Страница 25: ...the call Cancelling an Activation Occasionally you may trigger your alarm by accident and cause the TSD402 to send an unwanted call When this happens the unit may be stopped by entering a valid user...

Страница 26: ...from zone 1 5 F Final Exit when system is part set CODE TA Code Tamper 4 incorrect passcode entries ENTRY TO Entry timed out system not unset after activating F Exit zone FIRE AL Fire Alarm activated...

Страница 27: ...T Enter first 3 digits of Passcode then e g 5 6 7 USER OPTION Press 0 for Dailler Reporting options Dialler Reporting Options F123 P123 A123 When the display shows the required setting press to accept...

Страница 28: ...unsetting although it can be used for limited programming and testing of the system However if a menu option is selected which is not programmable using the remote keypad e g Dialler Programming all z...

Страница 29: ...he TSD402 has a facility called CHIME which generates a two tone sound from the control panel every time certain zones are activated Action To turn this facility on or off see the section on Changing...

Страница 30: ...and battery power for the system has been interrupted and the speech dialler messages have been erased Action Re program all messages as required contact your installation company for further advice...

Страница 31: ...simulate the modern dialling tones Contact your installation company for further details Problem The recipient has acknowledged the call but the TSD402 continues to dial the second or third number Cau...

Страница 32: ...Exit Instant System Reset By User Engineer Remote Reset Entry Time Seconds Exit Time Seconds Bell Duration Minutes Dialler Reports Fire Away PA Away Alarm Away Fire Home PA Home Alarm Home Installatio...