Point ID Extended Format
When the DC58/58M is used in the "plug-on mode"
(i.e., connected to a Menvier control panel) it is
possible to send additional alarm information to
the ARC, this can include circuit and user ID. For full
details on the extended information refer to the
relevant control panel "Installation Manual".
+
This feature is only supported by relevant
Menvier control panels, for details on
which control panels support this feature
contact Menvier Technical Support.
Point ID can be set to one of the following reporting
options:
1 Will NOT Report
This disables "Point ID Extended Format" and
the DC58/58M will only report "Fast Format"
data to the alarm receiver.
2 Limited Report
When "Limited Report" is selected the
DC58/58M will only report the extended format
data relating to the channel that is triggered.
For example, if the DC58/58M is programmed
to report channels 2 and 3 (PA and Intruder)
then the unit will only report events relating to
PA and Intruder activations.
3 Full Report
When "Full Report" is selected the DC58/58M
will report all extended format data to the
alarm receiver irrespective of the channels
that are programmed to report. That is, if all
eight channels are programmed as non
reporting, the unit will still report all events to the
ARC.
Temporary Out of Service
This feature is used to test the integrity of the
telephone line by dialling all but the last digit of the
first telephone number. If the unobtainable tone is
NOT detected it is assumed that the line is in good
working order, however, if an unobtainable tone is
detected the DC58/58M will signal a line fault
condition.
Ring Count (DC58M Only)
The DC58M Ring Count can be programmed for
one of the following options:
1 Instant
The DC58M will answer any incoming calls
immediately.
2 Delayed
The DC58M will answer any incoming calls
after approximately 30 seconds.
+
Some Menvier control panels allow the
ring count to be performed by the
control panel. If the control panel has a
ring count option then set the DC58M to
"Instant" and program the panel ring
count to the required amount.