![Mendota ML39-PF2 Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/mendota/ml39-pf2/ml39-pf2_installation-and-operating-instruction-manual_1770825048.webp)
85-03-00955
P a g e
|
48
ATTENTION!
The transmitter and receiver are RADIO FREQUENCY DEVICES. Placing the receiver in or near metal may se-
verely reduce the signal range.
Turn off the main gas supply of the appliance during installation or maintenance of the receiver.
Toggle the Master Switch to OFF during installation or maintenance.
Turn “off” main gas supply to the appliance prior to removing or reinserting the batteries in the receiver.
During appliance installation/maintenance or in case of remote control malfunction, turn off electrical supply to this
appliance and disconnect the Backup batteries from the wall DC connector. Contact technical service.
IPI/STANDING PILOT SYSTEM INFORMATION
Intermittent Pilot Light and Standing Pilot Light Features
This gas fireplace is equipped with an electronic ignition System that first lights a pilot light then uses the pilot light to ig-
nite the main burners. The pilot light can be set in the CPI (Standing Pilot) mode to allow the pilot light to remain on indef-
initely by setting the Remote Transmitter to CPI mode. If the remote transmitter is set to the IPI (Intermittent Pilot) mode,
the pilot light will only light and remain ON while the main fireplace burners are operating.
IPI Mode:
This mode turns the pilot light “OFF” when the fireplace is not functioning and only lights the pilot light automat-
ically when a call for heat is made by the remote control.
(CPI) Standing Pilot Mode:
If set to CPI Mode, the pilot light will ignite and remain ON at all times.
Setting To IPI versus CPI Mode
:
With the remote transmitter OFF, press the
MODE button. You will see either “CPI” or “IPI”
displayed on the transmitter screen. Press the UP
arrow button to set “CPI” mode and press the
DOWN arrow button to set “IPI” mode. One set to
the desired setting, press On/Off button to acti-
vate the fireplace.
NOTE
: Mendota Fireplaces recommends that the
(CPI) Standing Pilot Mode be used during the
winter months when the average daily high tem-
perature falls below 50
o
F. This will keep the fire-
place chimney heated for proper updraft during
burner ignition and it will also eliminate excessive
condensation of exhaust vapors on the door
glass. Further, leaving the fireplace in the Stand-
ing Pilot Mode will keep the fireplace body warm
and eliminate cold drafts and heat loss to the cold
air that is trapped inside the firebox.
REMOTE CONTROL
WALL RECEIVER
Supply voltage
4.5V (three 1.5V AAA batteries)
6.0V (four 1.5V AA batteries)
Ambient temperature ratings
32 – 122
o
F (0 – 50
o
C)
32 – 140
o
F (0 – 60
o
C)
Radio Frequency
315 MHz
315 MHz