3.2.5
Venting
The ML -Se ir e s Fir e plac e must be ve nte d to the outside and must use one of the appr ove d c oax ial r igid
duc ting syste ms. You may also use an appr ove d powe r ve nt.
Do Not Use any silicone sealants at pipe
joints. Stove gasket cements may be used at pipe joints but is not required
.
The ML-Series Fireplaces requires coaxial rigid-
5” diameter exhaust & 8” diameter air inlet and approved vent caps for most
installations.
All UL Listed Coaxial Rigid 5”X8” Vent pipe components and vent caps are approved for use. Do not mix components of different
brands or series. Always use the same brand and series components throughout the entire vent system.
A ll war r antie s will be voide d and se r ious fir e , he alth or othe r safe ty hazar ds may r e sult fr om any of the
following ac tions: Installation by unauthor ize d pe r sonne l; installation of any damage d c ompone nt;
unauthor ize d modific ation of ve nt syste m; installation of any c ompone nts not appr ove d by Me ndota; failur e
to me e t all c le ar anc e r e quir e me nts; failur e to pr ope r ly twist -loc k and positive ly se al all c ompone nts.
Consult loc al building c ode s be for e be ginning the installation.
W A RNING: A lways maintain r e quir e d c le ar anc e s (air spac e s) to c ombustible s to pr e ve nt a fir e hazar d. Do
not fill air spac e s with insulation. Che c k installation instr uc tions for minimum c le ar anc e r e quir e me nts
be twe e n the oute r walls of the ve nt pipe and ne ar by c ombustible sur fac e s. Be sur e to c he c k the ve nt
te r mination c le ar anc e r e quir e me nts fr om de c ks, windows, soffit, gas r e gulator s, air supply inle ts, and public
walkways, as spe c ifie d in the se installation instr uc tions and loc al building c ode s.
SAFETY PRECAUTIONS FOR THE INSTALLER: 1) Wear gloves and safety glasses for protection; 2) Exercise extreme caution when
using ladders or on rooftops; and 3) be aware of electrical wiring locations in walls and ceilings.
This gas applianc e and ve nt syste m must be ve nte d dir e c tly to the outside of the building, and ne ve r
attac he d to a c himne y se r ving anothe r solid fue l or gas bur ning applianc e . Eac h dir e c t ve nt gas applianc e
must have its own se par ate ve nt syste m. Common ve nt syste ms ar e pr ohibite d.
To assur e pr ope r ve nting pe r for manc e of this high -pe r for manc e
Me ndota Dir e c t Ve nt Fir e plac e , it is c r itic al that all br ands of ve nt pipe
se c tions ar e se ale d tightly and le ak -pr oof. This me ans that all pipe
se c tions must be c ar e fully r otate d into the fully "twist -loc ke d" position.
We strongly recommend that fixed length pipe sections be used in place of telescoping
sections whenever possible.
3.2.5.1
COMPONENT "TWIST-LOCK" CONNECTION PROCEDURE
DuraVent and American Metals pipe and fittings are designed with special twist-lock
connections. Twist-lock procedure is as
follows: four (4) indentations, located on the female ends of pipes and fittings are
designed to slide straight in to the male ends of the adjacent pipes and fittings, by
orienting the four pipe indentations so that they match and slide into the four entry
slots on the male ends.
Push the pipe sections completely together then twist-lock one section
clockwise, approximately ¼ turn until the two sections are fully locked. The
female locking lugs will not be visible from the outside on the black pipe or
fittings. They may be located by examining inside of the female ends.
3.2.5.2
Wall Heat Shield for Horizontal Vent Caps
Always use heat shield (#AA-11-00458) when the exterior wall covering is
made of vinyl, wood or other combustible materials. Heat shield (# AA-11-
00458) or an equivalent heat shield shall be installed. Heat shield (# AA-11-
00458) is available for order directly from Mendota fireplaces.
HEAT SHIELD #AA-11-00458
Содержание ML39- AA-11-04391
Страница 2: ...85 03 01205 ML SERIES FIREPLACE HOMEOWNER NOTES...
Страница 16: ...85 03 01205 ML SERIES FIREPLACE Page 16 Figure 3 10 Figure 3 9...
Страница 87: ...85 03 01205 ML SERIES FIREPLACE Page 87 ML72 Gas Train Assembly Parts...
Страница 94: ......
Страница 95: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...