background image

85-03-01205 

ML-SERIES FIREPLACE 

Page 

18

 

CERTIFIED  TO

: ANSI Z21.88/CSA 2.33 

This Mendota Gas Fireplace has been tested and certified by: 
Intertek Testing  Services, 8431 Murphy Drive, Middleton, WI 53562 

ICBO#AA647-4 

3.2.6

 

Normal Surface Temperatures 

WARN I N G:  The   supplie d  bar r ie r  scr e e n m ust  be  inst alle d ,  alw ays,  w he n t his  fir e place   is in  ope r at ion.   Do 
not  place   any  obje ct   dir e ct ly  in fr ont  (wit hin 

6 0 ”

 fr om  bar r ie r  scr e e n sur face )  or  dir e ct ly  above  (on  t he  

fr ont  e dge  of t he  m ant e l).  This  is  a he at ing  appliance .   Ar e as  dir e ct ly in  fr ont  and  above   t his appliance   will 
be  ve r y hot  and  can  dam age   m ost  house hold  obje ct s  if place d  t oo close .   Ke e p Fur nit ur e  pie ce s  at  le ast  

6 0 ”

 away  in fr ont  of  t he  bar r ie r  scr e e n  sur face .  

HINT:   To  gr e atly r e duc e  sur fac e  te mpe r atur e s sur r ounding this  Fir e plac e  dur ing ope r ation,  Me ndota 
r e c omme nds ope r ating  the  inte gr ate d c onve c tion air  blowe r s whic h  aid in c ooling all  sur r ounding sur fac e s.  
Mendota Fireplaces comply with ANSI Z21.88-2017/CSA 2.33-2017 Standards for maximum  surface temperatures on exposed 

“combustible”  surfaces adjacent to the 

Fireplace. 

Be aware that surfaces in front of, above and adjacent to this heater appliance can be too hot to touch.  If all required clearances 
to combustibles are met and the required finishing materials  are used, this appliance will perform safely. Note that the exposed 
surfaces immediately  surrounding the  Fireplace can have surface temperatures that are too hot to touch. This level of surface 
temperature is considered normal and does not indicate any hazardous situation. 

3.2.6.1

 

Surround Face Temperatures 

Areas of the breastplate directly above the top 
convection air gap of this Fireplace can be very hot (too 
hot to touch) and is deemed normal.  

3.2.6.2

 

Mantel Temperatures 

Mendota Fireplaces comply with ANSI Z21.88-2017/ 
CSA 2.33-2017 standards for maximum  surface 

temperatures on exposed “combustible”  su

rfaces 

adjacent to the Fireplace.  Be aware that surface in 
front of, above and adjacent to this heater appliance 
can be too hot to touch. As long as all required 
clearances to combustibles are met and the required 
finishing materials are used, this appliance will perform 
safely. Note that the exposed surfaces immediately 
surrounding the Fireplace can have a surface 
temperature too hot to touch. This level of surface 
temperatures is considered normal and does not 
indicate any hazardous situation. 

WARNING: Surfaces surrounding this Fireplace can be very hot to the touch during operation. Carefully supervise children and 
pets while this Fireplace is operating. 

 

 

 

Figure 3-11 Hot Zones 

Содержание ML39- AA-11-04391

Страница 1: ...et appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez aucun interrupteur Ne pas vous servir des t l phones se trouvant dans le b...

Страница 2: ...85 03 01205 ML SERIES FIREPLACE HOMEOWNER NOTES...

Страница 3: ...has been completed all smoking will have stopped Some slight odors may remain With subsequent use of this Fireplace odors will slowly dissipate and disappear ODOR RISKS If this appliance is not operat...

Страница 4: ...ING GUIDES 30 3 2 3 GRACE FRONT GUIDE OPTIONS 30 3 2 3 1 Flush Mount Installing The FrontOn Top OfFinishing Materials With TheScreen Recessed 30 3 2 3 2 Recessed Mount Installing FrontRecessed Into Wa...

Страница 5: ...OT DEFINED 5 7 1 Setting to IPI or CPI mode Error Bookmark not defined 5 8 FIRST TIME LIGHTING INSTRUCTIONS 76 5 8 1 Safety Information 76 5 9 OPERATING INSTRUCTIONS 77 5 10 TO TURN OFF GAS TO FIREPLA...

Страница 6: ...ode authorities for details on installation requirements The Mendota Fireplace must be vented to the outside in accordance with the latest edition of the National Fuel Gas Code In the absence of local...

Страница 7: ...dota gas fireplacesare heat producing appliances Do not burn wood paper or other materials in this fireplace This fireplace is designed as a supplemental heat source It is advisable to have an alterna...

Страница 8: ...clear of all obstacles and materials for servicing and proper operation Use only Mendota approved Screens Fronts and Trim Kits Due to high temperature the fireplace should be located out of traffic ar...

Страница 9: ...eplace heater is not for use with air filters Foyer au gaz vacuation Ne pas utiliser avec du combustible solide Keep burner and control compartment clean See installation and operating instructions ac...

Страница 10: ...State Building Code 3 A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the ex...

Страница 11: ...openings in the fireplace Always use Mendota decorative fronts and Mendota approved vent systems and vent caps only 3 1 1 Mendota Fireplace Curing Instructions ATTENTION It is important that the blow...

Страница 12: ...re are variables that can extend or shorten the curing time such as decorative fronts doors facing materials and their application Finish materials around the fireplace are subject to high temperature...

Страница 13: ...ting a location for your appliance it is important to consider the required clearances to walls ML39 ML47 ML54 ML60 ML72 A MINIMUMFRAMING DEPTH 19 1 2 B FINISHEDFRAMING WIDTH 48 54 61 67 78 C MIN ENCL...

Страница 14: ...S FIREPLACE Page 14 3 2 3 Listing Labels The listing label is located under the firebox Remove the right side access grill and locate the listing plate It is chained to the shut off valve handle Figur...

Страница 15: ...his appliance body as required per code to inform you of important facts You can find these labels on the outer surface of this appliance Make certain you heed all the warning and caution statements d...

Страница 16: ...85 03 01205 ML SERIES FIREPLACE Page 16 Figure 3 10 Figure 3 9...

Страница 17: ...APPROVED FOR USE WITH MENDOTA POWER VET KITS AA 11 04071 AA 11 04072 and AA 11 04100 All UL Listed Coaxial Rigid 5 X8 Vent pipe components and vent caps are approved for use Do not mix components of...

Страница 18: ...h If all required clearances to combustibles are met and the required finishing materials are used this appliance will perform safely Note that the exposed surfaces immediately surroundingthe Fireplac...

Страница 19: ...ING 60 62 64 1 4 64 1 4 54 F MIN UNITBASETO 8 MANTEL 45 47 49 49 51 G UNITBASE TO VENTCENTERLINE 53 55 57 1 4 57 1 4 47 1 8 H MIN FRAMING HEIGHT 40 42 44 1 2 44 1 2 46 1 2 Figure 3 12 Overall Fireplac...

Страница 20: ...E UNITBASE TO INNERGUIDE 9 1 2 9 1 2 9 3 8 9 3 8 9 1 2 F UNITSIDE TO CENTER OF VENT 23 3 8 26 3 8 30 33 38 1 2 BOTTOM OFUNITTO VENTSTARTER COLLAR 30 3 4 32 3 4 35 35 37 Figure 3 13 FIREPLACE DIMENSIO...

Страница 21: ...ch as lifting the fireplace onto a transport cart or shifting the fireplace during installation Do not attempt to carry this fireplace by the lifting handles only Note Team lifting is recommended To u...

Страница 22: ...in a cavity deeper than 19 1 2 all framing and finishing materials protruding past the front face of this fireplace must be of the NON COMBUSTIBLE variety MINIMUM REQUIRED FRAMING DIMENSIONS INCHES MO...

Страница 23: ...e and cantilever floor of the chase should be insulated Vapor and air infiltration barriersshould be installed in the chase as per regional codes for the rest of the home Additionally in regions where...

Страница 24: ...85 03 01205 ML SERIES FIREPLACE Page 24 3 2 11 Clearance from Appliance Side Walls Figure 3 17 CLEARANCE TO BODY...

Страница 25: ...providesat least a 1 active airspace on the combustible wall surface To provide for active airflow install at least 1 metal or ceramic standoffs or spacers between the metal shield and the combustible...

Страница 26: ...y result in a fire causing property damage personalinjury or loss of life NOTE For mantels that protrude more than 8 inches from thefront surfaceof thefireplace use a rise and run of 1 1 to calculate...

Страница 27: ...sclaims any and all liability for any damage to finishing materials including warping discoloring cracking peelingor flaking This also includes any off gassing or unpleasant smells from materials when...

Страница 28: ...se of ceramic or porcelain tiles as facing materials around a Mendota fireplace is approved If selecting a mosaic tile where tiles are held together with a webbing ensure the webbing is a non combusti...

Страница 29: ...to emission of chemicals with unwanted smells 3 2 1 5 Suitable Paints and Sealant Materials 3 2 1 5 1 Paint Types Approved for Use Industrial Acrylic Paints Alkyd based Paints When selecting paint for...

Страница 30: ...UIDE OPTIONS This fireplace comes with guides to ensure finish materials do not encroach into the convection air area of the fireplace Some decorative Front models for this fireplace come with additio...

Страница 31: ...llingFront RecessedInto Wall Note You must order Recessed mount guide kit This option allows the front to mount with any finish material It is a recessed finish Use the reference chartor pricing sheet...

Страница 32: ...ed maximum operation temperatures Mendota Hearth will not be held liable for any adverse effects on a television or other products locate d near to a Mendota Hearth fireplace The drawings below show r...

Страница 33: ...e heat from the fireplace and redirectit to another area When use d correctly these heat transfer systems can make it possible to mount a television above the fireplace without installing a mantel or...

Страница 34: ...e ON OFF key Release the MODE key Press the MODE key once to highlight the convection fan function 4 While still holding the ON OFF key pressthe DOWN ARROW key The display will change from Set to Clr...

Страница 35: ...lace for mounting a television the Versiheat system must always be on when the fireplace is in operation Because the Versiheat system must be running to reduce temperatures the fireplace cannot be ope...

Страница 36: ...above the fireplace for mounting a television the FlexHeat system must always be on when the fireplace is in operation Because the FLexHeat system must be running to reduce temperatures the fireplace...

Страница 37: ...glasses for protection 2 Exercise extreme caution when using ladders or on rooftops and 3 be aware of electrical wiring locations in walls and ceilings This gas appliance and vent system must be vent...

Страница 38: ...g requirements and venting restrictions ITEM DESCRIPTION 1 6 or 7 PIPE DuraVent 6 Amerivent 7 9 12 2 12 VENT STACK 3 24 VENT STACK 4 36 VENT STACK 5 48 VENT STACK 6 90 GALVANIZED ELBOW 6a 45 GALVANIZE...

Страница 39: ...UM APPROVED APPROVED APPROVED APPROVED NOT ALLOWED APPROVED H2 V H2 H2 V2 V1 V2 V V H1 H1 H1 H STRAIGHT UP VERTICAL VENTING THREE HORIZONTAL DISCHARGE 90 ELBOWS VERTICAL RISE TRIPLE 90 ELBOWS VERTICAL...

Страница 40: ...18 inches 45 cm recommended to prevent condensation on window J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 inches 30 cm minimum D V...

Страница 41: ...stem gas appliances are terminated next to each other the minimum required distance between the vertical center line of the vent caps is 18 to prevent recirculation of exhaust from one vent cap outlet...

Страница 42: ...ction box cover plate secured with four screws route the 3 wire end of an extension cord or house power wire cable through the strain reliefsin the cover plate 2 Locate in the manual packet the plug s...

Страница 43: ...Two cover plates are supplied and are White and Beige in color If the home d cor requiresa different color other than the two supplied colors obtain one from a local hardware store Make certain that...

Страница 44: ...ntrol Wiring Errors can cause improper and dangerous operation Verify proper operation after servicing 3 3 4 Wi Fi Dongle and Application This appliance has the capability to be controlled via an appl...

Страница 45: ...ELIMINATE THE POSSIBILITY OF CONTAMINANTS ENTERING THE GAS TRAIN ADHERE STRICTLY TO LOCAL AND NATIONAL CODES 3 4 2 Gas Supply Line Sizing This Mendota Gas Fireplace comes equipped with a 1 2 N P T Fem...

Страница 46: ...ly piping system by closing its equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa 3 4 4 Drip Leg Recommended...

Страница 47: ...e upward 90 degreesor until it stops Figure 3 31 EMERGENCY GAS SHUTOFF 3 4 7 Gas Inlet Fittings Information Caution Before you run the gas line read understand and properly calculate the required gas...

Страница 48: ...dy has the orifice hole size stamped on it LPG orifice size shall be 50 ML39 48 ML47 49 ML54 and ML60 and 46F 54R ML72 for 0 2000 ftand 51 ML39 49 ML47 ML54 or ML60 and 46F 54R ML72 for 2000 5000ft Ve...

Страница 49: ...a Mendota approved servicepersonin accordance with instructions All joints are secured twist locked and leak proof Horizontal or verticalvent cap is installed right side up and tightlysealed to struct...

Страница 50: ...let and Fireplace To remove the outer box identify and remove four Philips head drywall screws that secure a cardboard L pincher at the bottom of each corner of the box Lift the outer box vertically s...

Страница 51: ...decorative front are not included with this base Fireplace product One of the many log set and media options firebox inner liner options and decorative fronts options must be selected and purchased s...

Страница 52: ...nter glass frame over firebox left to right 3 After door has been placed into slots rotate door towards firebox until gasket seal is touching the firebox frame 4 Use the tool provided to connect the s...

Страница 53: ...s to handle the light bulb Touching the light bulb will leave oils and dirt on the lens and will cause premature failure of the light bulb 3 Use a 3 8 hex hand driver to loosen the nuts 4 Remove the l...

Страница 54: ...fireplace cavity Follow the step below to prepare this fireplace for conversion to LP gas 1 Remove the glass frame Directions to remove the glass frame are in this manual See section TO REMOVE DOOR 2...

Страница 55: ...emove the orifice When removing and installing the orifices be sure to use a wrench to keep the fitting the orifice screws onto from rotating The ML72 has two air shutter boxes both orifices need to b...

Страница 56: ...etail view below If you see NAT printing on the adjustment clip this indicates that the pilot is set to burn natural gas Push the clip in so that NAT is not visible 8 Tighten down hex shaped base of p...

Страница 57: ...s pre fitted as part of assembly E 3 See Figure 3 12 Figures 3 and Figure 3 12 4 Install the new stepper motor pressure regulator assemble Use the provided screws F M4 x 0 7 threaded length of thread...

Страница 58: ...leak proof WARNING Do not proceed with operation of this fireplace unless burner cycles on off without delays 4 8 3 Pilot Flame and Burner Relationship Verification Prior to completing the LPG convers...

Страница 59: ...on requirements The Mendota Fireplaces must be vented to the outside in accordance with the latest edition of the National Fuel Gas Code In the absence of local c odes the installation must conform wi...

Страница 60: ...mum Vent System length allowed is 46 feet Maximum number of 90o elbows allowed in Zone A is 3 and in Zone B is 4 In Zone A 32 feet maximum horizontal run allowed with a 4 feet starter section for NG a...

Страница 61: ...ection Is Less Than 4 For vent systems that provide a starting vertical section less than 4 the following rules apply A You must use the Master Venting Requirements Chart B A single 90 vertical to hor...

Страница 62: ...exterior wall Cut and frame a 10 3 4 wide x 10 3 4 high opening in the wall The hole must be positioned so the vent system will run level or have a rise per foot of run AND be perpendicular to the wal...

Страница 63: ...ipe sections overlap we suggest pre assembling and measuring the total vent pipe run so you can more accurately locate the point where the vent pipe will penetrate the outside wall Be sure all vent co...

Страница 64: ...S FIREPLACE Page 64 V 2 MIN H1 H2 MAX 2 3 3 16 4 32 4 12 32 For V greater than 12 see Master Venting Chart Vertical Rise Three 90 Elbows Horizontal Termination Use the Master Venting Chart to calculat...

Страница 65: ...r pipe joints are sealed and are leak proof Maintain 1 airspace clearancesto combustibles 2 above horizontal runs Cut a 10 x 10 opening in the roof centered in the small drilled hole placed in the roo...

Страница 66: ...iderable time and effort in the design of this fireplace and its venting system Through this effort Mendota has been able to certify the use of Four 900 elbows The use of Four 900 elbows must meet som...

Страница 67: ...proved Vent Systems One of three power vents may be installed with this fireplace Choose the correctpower vent according to the required vent r un For detailed installation instructions follow the inc...

Страница 68: ...85 03 01205 ML SERIES FIREPLACE Page 68 4 11 2 Power Vent Exterior Vent Locations and Restrictions Note All measurements are to be taken from the edge of the Power Vent...

Страница 69: ...r installation To adjust the damper look into the convection air cavity and note the Damper Position Indicator Hook glass latch tool in the hole at the end of the damper rod pull outward about 1 8 and...

Страница 70: ...g procedure NOTE All adjustments to the air shutter setting must be made by a qualified installer service agency or the gas supplier Very small changes in shutter settings make major changes in fl ame...

Страница 71: ...us in any room In addition to offering the most realistic log details textures coloration and the most realistic wood fire options Mendota also offersa large array of internal firebox lining options a...

Страница 72: ...ll operate When the master switch is in the on condition the main burners will function as designed In case of an emergency toggle the master switch to off to turn off the main burners To synchronize...

Страница 73: ...This can occur if the remote control is moved to another room or if the remote batteries are very weak b Normal Thermostat On In this mode the fireplace will turn itself on and off dependingon the tem...

Страница 74: ...ning Smart Thermostat a If the thermostat icon displays as OFF Manual the fireplace will ignite and start on Hi b If the thermostat icon displays as ON Normal Thermostat the fireplace will only ignite...

Страница 75: ...off or adjust the fan speed Once you set the desired fan control the system will remember your selected fan speed until you manually change it Accent Light This function controls the accent light fun...

Страница 76: ...elow 50 F This will keep the fireplace chimney heated for proper updraft during burner ignition and it will also eliminate excessive condensation of exhaust vapors on the door glass Leaving the firepl...

Страница 77: ...t fails to light the system will lockout PressON OFF button on remote control to Turn Off the system and reset the lockout Allow five minutes for any gas in the unit to dissipate before attempting to...

Страница 78: ...11 2 Where can I find the model and serial numbers When requesting service you will be asked to provide the model number and serial number to your Mendota dealer This information will expedite the wa...

Страница 79: ...e condition of any wiring under the burner for melting or damage 2 Clean pilot light flame sensor rod and sparker rod using emery cloth Vacuum clean pilot light assembly 3 Visual check of pilot flames...

Страница 80: ...not covered under warranty 5 11 7 What should I do if my fireplace is sooting Sooting is caused by improper installation or air shutter operation However some small areas of soot deposits on log surfa...

Страница 81: ...button down 4 If you see set the thermostat button is now enabled 5 If you see clear the thermostat button is disabled 6 Repeat this procedure if you did not see set or clear to add remove the thermo...

Страница 82: ...e viewing glass should be cleaned periodically Exterior glass surface may be cleaned with cleaner as desired To clean Interior glass surface remove glass frame assembly See 4 5 To Remove Door Use Kel...

Страница 83: ...review and calculation of proper main burner orifice sizes prior to first firing It is known that unpurified Natural Gas from backyard wells can contain high energy levels causing over firing Further...

Страница 84: ...of the burner to the floor Then slide the burner to the left to remove the burner tube from the shutter box Detailed instructions for removing the burner can be found in the converting to LPG section...

Страница 85: ...ls The blowers are located under these panels towards the rear of the fireplace The blower assemblies are attached to the floor with two nuts Remove the nuts and lift the blower assemblies out of the...

Страница 86: ...85 03 01205 ML SERIES FIREPLACE Page 86 6 6 4 Gas Train Assembly Parts ML39 Gas Train Assembly Parts ML47 ML54 and ML60 Gas Train Assembly Parts...

Страница 87: ...85 03 01205 ML SERIES FIREPLACE Page 87 ML72 Gas Train Assembly Parts...

Страница 88: ...ct the glass surface Use tracer lines in gasket to determine where the glass should sit on the gasket surface 4 Place glass and gasket assembly in glass frame and carefully bend down glass retainer ta...

Страница 89: ...nual Burner flames are stable and are not lifting off burner Inform owner that an initial curingstep is required Read and follow Mendota Fireplace and Insert Curing Instructions found on unit and in o...

Страница 90: ...ss thermal breakage only STD Stainless Steel Burner Tubes Ceramic Burners STD All Castings EXT STD Valve Assembly and all gas control components Pilot Assembly Flame Sensor Spark Electrode PilotTubing...

Страница 91: ...ed to be defective prior to processing or authorizing of any claim Failure to allow this upon request will void the warranty All warranty claims must be submitted by the dealer servicing the claim inc...

Страница 92: ...covered under the terms of this warranty 14 Freight damages for products or parts are not covered under the terms of the warranty 15 Products made or provided by other manufacturers and used in conjun...

Страница 93: ...s must register with Mendota to qualify for the Lifetime Limited Warranty within 3 0 days Product registration will activate your Lifetime Limited Warranty Owners should complete the forms available a...

Страница 94: ......

Страница 95: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...

Отзывы: