Mendota FV34 Скачать руководство пользователя страница 28

85-03-01107 

FV34 DECOR 

Page 

28

 

 
The polyester resin used on mar ble slabs can discolor when exposed to temperatures greater than 150

o

and will structurally fail at temperatures above 230

o

F. The epoxy resin coating used on granite slabs are 

resistant to discoloring and structural failures up to 350

o

F. Mendota does not assume any liability for 

discoloring, flaking or cracking of marble or granite.  
Temperatures on facings around Mendota fireplaces can reach 350

o

F directly 

outside the top convection air gap. These temperatures will discolor 
polyester resin coated marble facings and can cause the polyester resin 
coating to fail near the top convection air gap. 
Mendota cannot guarantee suitability of use of any marble slabs 
or tiles that have a polyester resin coating applied to it and 
cannot guarantee against discoloration or structural failure of 
marble or polished stone facings that have a polyester resin 
coating. Consult with your local stone supplier.  
Prior to use of any marble, granite or polished stone facing material, 
especially white colored ones, run heat exposure tests on a sample piece. 
Expose sample pieces to temperatures between 275

o

F and 350

o

F for a period 

of eight hours. Compare the heat exposed sample to a control unheated 
piece and judge for color changes. Do not use if any color changes are evident. 
Mendota recommends the use of honed bare marble and bare stone facing materials or honed bare granite 
and epoxy resin coated granite only.  
Mendota cautions that due to natural structural defects that can exist within marble and stone pieces, cracking and/or flaking 
of the marble or stone is possible and must be considered prior to selection and application around Mendota fireplaces. 
Mendota further cautions that proper adhesives be used to attach stone facings. Pay attention to the potential of off gassing of 
chemical vapors from mastic and other adhesives. Improper selection can lead to emission of chemicals with unwanted smells. 

 

Suitable Paints and Sealant Materials 

3.2.2.5.1

 

Paint Types Approved for Use 

 Industrial Acrylic Paints, Alkyd based Paints. When selecting paint for applications on facings, mantels, corbels or floors within 

2’ in front of a fireplace raised 6” or higher, avoid off the shelf paints which may have modifier ad

ditives used to increase 

“hiding” ability, accelerate drying times and curing times. Consult with a reputable paints and sealants supplier and acquire

 

industrial acrylic paints or alkyd-based paints. 

3.2.2.5.2

 

Sealants Type Approved for Use 

Heat resistant polyurethane sealants which are not damaged by prolonged exposure to raised temperatures. Many are flame 
resistant, meaning that they resist ignition when exposed to high temperatures and can insulate the substrate and delay 
damage to it. When selecting polyurethane 

for applications on facings, mantels, corbels or floors within 3’ in front of or above a 

fireplace, avoid off the shelf urethane sealants which may have modifier additives used to accelerate drying times and curing 
times. Consult with a reputable paints and sealants supplier and acquire heat resistant polyurethane sealants. 

3.2.2.5.3

 

Wood Application Cautions 

If wood used around or in front of the fireplace has been chemically cleaned or bleached prior to staining or painting, it is of the 
utmost importance to make certain that the cleaner or bleach does not remain in the wood substrate under the final paint or 
sealant applied. If any cleaner or bleach remain within the wood structure, application of heat from the fireplace, even low-level 
heat, will cause the cleaner or bleach compounds to expand or evaporate causing separation of the paint or sealant from the 
wood surface and may cause peeling or bubbling of the paint or sealant. 
Moisture content of the wood substrate is also of critical importance. High moisture content wood when heated will yield 
evaporation of the moisture and hydraulic pressure under the paint or sealants which can lead to peeling or bubbling. Always 
select the lowest moisture content wood substrate. 

 

 

 

Figure 3-22 Top Air Gap 

TOP AIR 
GAP 

Содержание FV34

Страница 1: ...FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Ne touchez aucun interrupteur Ne pas vous servir des t l phones se trouvant dans le b timent o vous trouvez Appelez imm diateme...

Страница 2: ...been completed all smoking will have stopped Some slight odors may remain With subsequent use of this Fireplace odors will slowly dissipate and disappear ODOR RISKS If this appliance is not operated...

Страница 3: ...oved for Use 28 3 2 2 5 2 Sealants Type Approved for Use 28 3 2 2 5 3 Wood Application Cautions 28 3 2 5 3 1 Mendota Cool Wall33 3 2 5 3 2 Versiheat 34 3 2 5 3 3 FlexHeat 35 3 3 ELECTRICAL TECHNICAL R...

Страница 4: ...FAHRENHEIT 77 5 8 FIRST TIME LIGHTING INSTRUCTIONS 78 5 9 OPERATING INSTRUCTIONS 78 5 10 TO TURN OFF GAS TO FIREPLACE 78 5 11 FREQUENTLY ASKED QUESTIONS 79 6 1 REQUIRED PERIODIC INSPECTIONS 83 6 2 CL...

Страница 5: ...uthorities for details on installation requirements The Mendota Fireplace must be vented to the outside in accordance with the latest edition of the National Fuel Gas Code In the absence of local code...

Страница 6: ...nt du panneau un technicien agr WARNING Mendota gas fireplaces are heat producing appliances Do not burn wood paper or other materials in this fireplace This fireplace is designed as a supplemental he...

Страница 7: ...all obstacles and materials for servicing and proper operation Use only Mendota approved Screens Fronts and Trim Kits Due to high temperature the fireplace should be located out of traffic areas and...

Страница 8: ...replace heater is not for use with air filters Foyer au gaz vacuation Ne pas utiliser avec du combustible solide Keep burner and control compartment clean See installation and operating instructions a...

Страница 9: ...e Building Code 3 A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust...

Страница 10: ...he gas supplier Any adjustments to burner pilot logs or coal bed must be made by a qualified installer service agency or the gas supplier If ignition system goes into lockout mode always wait 5 minute...

Страница 11: ...When odors have diminished leave the fireplace turned on and continue to Step 3 Step 3 Final Curing Cycle With the fireplace still turned on from Step 2 Set the Fan Speed Control to the lowest setting...

Страница 12: ...liance it is important to consider the required clearances to walls WARNING FIRE RISK ODOR RISK Install appliance on metal or wood surfaces extending full width and depth of this fireplace An R 1 Rate...

Страница 13: ...07 FV34 DECOR Page 13 Listing Label The listing label is in the air gap below the Fireplace It is secured to a chain and left loosely in the air gap and can be pulled out to be viewed Figure 3 1 Listi...

Страница 14: ...are attached to this appliance body and door glass as required per code to inform you of important facts Make certain you heed all the warning and caution statements during installation and maintenan...

Страница 15: ...85 03 01107 FV34 DECOR Page 15 Figure 3 10 Figure 3 9...

Страница 16: ...ries components throughout the entire vent system MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION UNIT TO FLOOR 0in 0mm GLASS EDGE TO ADJACENT SIDEWALL 16in 406 mm UNIT TO ENCLOSURE SIDEWALL 1 2in 13mm...

Страница 17: ...face temperatures that are too hot to touch This level of surface temperature is considered normal and does not indicate any hazardous situation Hearth Pad Temperatures New hearth protection pads inst...

Страница 18: ...FRAMING HEIGHT TH 42 1 2 TO CENTERLINE OF VENT CAP 24 MIN TO VINYL SOFFIT 18 MIN TO WOOD OR METAL SOFFIT MINIMUM ROUGH FRAMING DIMENSIONS HEIGHT 47 WIDTH 42 1 2 DEPTH 19 1 2 FROM UNIT BASE TO ROOM CEI...

Страница 19: ...SUPPLY INLET 1 2 FNPT 4 X6 COAXIAL STARTER COLLAR 11 5 16 40 5 8 MIN ROUGH FRAMING WIDTH 29 13 16 FLOOR TO VENT STARTER TOP GAS SUPPLY INLET THIS SIDE DETAIL A DC BACKUP POWER CORD EXIT 11 8 1 16 6 3...

Страница 20: ...e provided The lifting handles make it easy for two individuals to lift and transport this Fireplace WARNING The lifting handles are designed only for lifting and moving the fireplace short distances...

Страница 21: ...be constructed in the manner of all outside walls of the home to prevent cold air drafting problems The chase should not break the outside building envelope in any manner Wall ceiling base plate and...

Страница 22: ...pen The steel shield must be a minimum of 12 larger in each direction than the surface area of the source of heat or if the surface being protected is smaller than surface area of the source of heat t...

Страница 23: ...rom Floor Level of this Fireplace If you prefer to take measurements from the Top of the Convection Air Opening note that the Top of the convection air opening is 24 3 4 inches up from the floor level...

Страница 24: ...fireplace Mendota disclaims any and all liability for any damage to finishing materials including warping discoloring cracking peeling or flaking This also includes any off gassing or unpleasant smell...

Страница 25: ...n the front being installed If the guides that come on the fireplace are used the dimension A from the bottom of the fireplace to the bottom guide is 1 1 2 Other guide kits that are required for insta...

Страница 26: ...any and all liability for any damage to finishing materials including warping discoloring cracking peeling or flaking This also includes any off gassing or unpleasant smells from materials when they...

Страница 27: ...ramic or porcelain tiles as facing materials around a Mendota fireplace is approved If selecting a mosaic tile where tiles are held together with a webbing ensure the webbing is a non combustible mate...

Страница 28: ...sion of chemicals with unwanted smells Suitable Paints and Sealant Materials 3 2 2 5 1 Paint Types Approved for Use Industrial Acrylic Paints Alkyd based Paints When selecting paint for applications o...

Страница 29: ...manently left in place GRACE WILLOWBROOK MISSION FRONT GUIDE OPTIONS This fireplace comes with guides to ensure finish materials do not encroach into the convection air area of the fireplace Some deco...

Страница 30: ...ed Mount Guide Kit from the pricing sheet This option allows the front to mount with any finish material The front will fit inside the guides Allowing the front to be recessed into the wall If you are...

Страница 31: ...aximum operation temperatures Mendota Hearth will not be held liable for any adverse effects on a television or other products located near to a Mendota Hearth fireplace The drawings below show recomm...

Страница 32: ...om the fireplace and redirect it to another area When used correctly these heat transfer systems can make it possible to mount a television above the fireplace without installing a mantel or creating...

Страница 33: ...OFF key Release the MODE key Press the MODE key once to highlight the convection fan function 4 While still holding the ON OFF key press the DOWN ARROW key The display will change from Set to Clr to i...

Страница 34: ...for mounting a television the Versiheat system must always be on when the fireplace is in operation Because the Versiheat system must be running to reduce temperatures the fireplace cannot be operate...

Страница 35: ...ve the fireplace for mounting a television the FlexHeat system must always be on when the fireplace is in operation Because the FLexHeat system must be running to reduce temperatures the fireplace can...

Страница 36: ...otection 2 Exercise extreme caution when using ladders or on rooftops and 3 be aware of electrical wiring locations in walls and ceilings This gas appliance and vent system must be vented directly to...

Страница 37: ...LE 8 ATTIC INSULATION SHIELD 12 9 ROOF FLASHING 0 12 TO 6 12 10 ROOF FLASHING 7 12 TO 12 12 11 STORM COLLAR 12 VERTICAL VENT CAP 13 SUPPORT BAND 14 HORIZONTAL VENT CAP 15 FIRE STOP SPACER CAUTION ALL...

Страница 38: ...BOWS VERTICAL TERMINATION VERTICAL RISE DUAL 90 ELBOWS HORIZONTAL TERMINATION VERTICAL RISE TRIPLE 90 ELBOWS HORIZONTAL TERMINATION VERTICAL RISE TRIPLE 90 ELBOWS VERTICAL TERMINATION THREE HORIZONTAL...

Страница 39: ...rance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 inches 30 cm minimum D Vertical clearance to ventilated soffit located above the terminal fro...

Страница 40: ...appliances are terminated next to each other the minimum required distance between the vertical center line of the vent caps is 18 to prevent recirculation of exhaust from one vent cap outlet into the...

Страница 41: ...power to this Fireplace follow these steps 1 Remove the junction box cover plate secured with two screws route the 3wire end of an extension cord or house power wire cable through the strain relief in...

Страница 42: ...plates are supplied and are White and Beige in color If the home d cor requires a different color other than the two supplied colors obtain one from a local hardware store Make certain that the cover...

Страница 43: ...Replacement wires must have the same type and size of insulation as the original This appliance must be electrically connected and grounded in accordance with local codes or in the absence of local co...

Страница 44: ...ndota Gas Fireplace comes equipped with a 1 2 N P T Female inlet Gas supply piping must enter the Fireplace cabinet on the left side Use the table below to determine the proper gas line diameter that...

Страница 45: ...ly piping system by closing its equipment shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa Drip Leg Recommended It is...

Страница 46: ...ure 3 34 EMERGENCY GAS SHUTOFF Gas Inlet Fittings Information Caution Before you run the gas line read understand and properly calculate the required gas line size Improper too small gas line size app...

Страница 47: ...ation Verify main orifice size The main orifice body has the orifice hole size stamped on it LPG orifice size shall be for all elevations Verify that the manifold gas pressure is within 10 0 WC 1 8 Hi...

Страница 48: ...by a Mendota approved serviceperson in accordance with instructions All joints are secured twist locked and leak proof Horizontal or vertical vent cap is installed right side up and tightly sealed to...

Страница 49: ...nd Fireplace To remove the outer box identify and remove four Philips head drywall screws that secure a cardboard L pincher at the bottom of each corner of the box Lift the outer box vertically straig...

Страница 50: ...0 Installation Required Light Lens Assembly Packet HA 58 04608 Light Lens Lens Retainer Bracket w gasket four 10 24 Nuts Lens base gasket Installation Required Owner s Manual Must Leave with Homeowner...

Страница 51: ...up or removing them will be necessary for Fireplace units which are to be installed in narrow width or shallow depth openings To bend the clips up or to break them off follow these procedures 1 Insert...

Страница 52: ...nd move away from unit Door is now free from unit NOTE Always check glass gasket condition and gasket seal any time the glass door is removed and when reinstalling glass door 4 8 TO REPLACE DOOR 1 Lin...

Страница 53: ...re 4 7 Light Housing Caution Do not touch the light lens with bare hands Always use the protective foam wrap supplied with the light bulb or a pair of clean cloth or neoprene gloves to handle the ligh...

Страница 54: ...ance may result in property damage or personal injury Kit HA 58 00410 for Mendota Model FV34 DECOR This conversion kit shall be installed by a qualified service agency in accordance with the manufactu...

Страница 55: ...If you intend to burn LPG it is recommended that you convert this fireplace and its pressure regulator pilot orifice slider position and burner orifices prior to placing this fireplace in its framed...

Страница 56: ...orifice and also when installing and tightening the new LP orifice 5 Thread a new 52 drilled orifice to Orifice mounting brass fittings Tighten down orifice 6 Locate Pilot Light on right side of fire...

Страница 57: ...y seen Warning Installation should be carried out in a clean environment Warning This modulating conversion kit must only be applied as part of a conversion kit supplied by the fireplace manufacturer...

Страница 58: ...oals must not block pilot flame or main burner flame Vent system must be leak proof WARNING Do not proceed with operation of this fireplace unless burner cycles on off without delays Pilot Flame and B...

Страница 59: ...ented to the outside in accordance with the latest edition of the National Fuel Gas Code In the absence of local codes the installation must conform with National Fuel Gas Code ANSI Z223 1 NFPA 54 or...

Страница 60: ...point vertically upward and you must terminate the vent system vertically 7 For ALL horizontal terminations only 3 90o elbows allowed 8 For ALL vertical terminations four 90o elbows allowed However th...

Страница 61: ...system Each additional 90 elbow reduces the maximum horizontal distance allowed by 3 C If you plan to use more than one 900 elbow within the vent system first use the Venting Requirements Chart Figure...

Страница 62: ...g to allow the vent system to penetrate the wall 2 Measure from the floor level of the fireplace up 49 1 2 inches add rise for every foot of horizontal run and mark wall directly at the center of wher...

Страница 63: ...on proper vent cap placement on exterior of home Check to determine if wall studs are in the way when vent system is attached If this is the case you may want to adjust the fireplace location 2 Locat...

Страница 64: ...85 03 01107 FV34 DECOR Page 64 Figure 4 19 DUAL 90 DEG ELBOWS Figure 4 20 TRIPLE 90 DEG ELBOWS APPROVED...

Страница 65: ...at inner pipe joints are sealed and are leak proof Maintain 1 airspace clearances to combustibles 3 above horizontal runs Cut a 9 x 10 opening in the roof centered in the small drilled hole placed in...

Страница 66: ...85 03 01107 FV34 DECOR Page 66 1 2 3 4 5 13 15 9 10 11 12 40 FEET MAX...

Страница 67: ...ows when terminating vertically The use of Four 900 elbows must meet some minimum prerequisites Prerequisite 1 The vent system must terminate vertically using a vertical vent cap Prerequisite 2 There...

Страница 68: ...ging the flame characteristics after 20 minutes of burn time If the flames ghost off burners or if sooting occurs in LPG units open the vent damper FULLY and work backwards in increments to determine...

Страница 69: ...iamond Glass 9 Clear Ice Cubes 10 Liquid Clear Diamond Glass not shown 11 Tumble Marble not shown Figure 4 21 Driftwood Log Set w Natural Rocks Figure 4 22 Norway Spruce Log Set Figure 4 23 Birch Log...

Страница 70: ...is checked All lighting and log installation instructions were followed Burners light immediately and flame runs promptly across burner and lights entire burner Note Do not proceed with operation unle...

Страница 71: ...ed realistic yellow Use glass latch tool to hook to shutter control lever 3 If flame is too dark yellow or is causing soot on viewing glass or logs open air shutter fully until soot stops Continue bur...

Страница 72: ...ing fans The heat output of the fireplace can be reduced by reducing flame height using the remote control Blower can be turned down or turned off to reduce heat distribution 5 3 IMPORTANT INFORMATION...

Страница 73: ...the sync button contact your Mendota dealer or installer for assistance 3 Within seven seconds press the on button on the remote control The fireplace will beep four times to indicate that the remote...

Страница 74: ...ur if the remote control is moved to another room or if the remote batteries are very weak b Normal Thermostat On In this mode the fireplace will turn itself on and off depending on the temperature yo...

Страница 75: ...aning Smart Thermostat a If the thermostat icon displays as OFF Manual the fireplace will ignite and start on Hi b If the thermostat icon displays as ON Normal Thermostat the fireplace will only ignit...

Страница 76: ...ot available for manual adjustment In Smart Thermostat the flame height regulates automatically Fan Speed Control The fan speed can be adjusted through six speeds and off To activate this function pre...

Страница 77: ...ol OFF press the MODE button You will see either CPI or IPI displayed on the screen Press the Up arrow button to set CPI mode and press the DOWN arrow button to set IPI mode Once set to the desired se...

Страница 78: ...n audible beep then the igniter will begin to spark After the pilot lights and is established the valve will automatically open and the burner will light The burner will initially light to full flame...

Страница 79: ...Gas Shutoff Valve Requirement If local building codes require one obtain an external keyed wall mounted or floor mounted manual gas shutoff valve approved per local gas plumbing codes and install per...

Страница 80: ...y Installed Manual Gas Shutoff Valve 4 Turn OFF the external manual shutoff valve if one was required and supplied by installer and mounted adjacent to fireplace 5 Turn OFF all electric power to the f...

Страница 81: ...assistance Where can I find the model and serial numbers When requesting service you will be asked to provide the model number and serial number to your Mendota dealer This information will expedite...

Страница 82: ...r melting or damage 2 Clean pilot light flame sensor rod and sparker rod using emery cloth Vacuum clean pilot light assembly 3 Visual check of pilot flames is required Pilot flame must overlap flame s...

Страница 83: ...warranty What should I do if my fireplace is sooting Sooting is caused by improper installation or air shutter operation However some small areas of soot deposits on log surfaces are deemed acceptabl...

Страница 84: ...If you see set the thermostat button is now enabled 5 If you see clear the thermostat button is disabled 6 Repeat this procedure if you did not see set or clear to add remove the thermostat option Why...

Страница 85: ...ned periodically Exterior glass surface may be cleaned with cleaner as desired To clean Interior glass surface remove glass frame assembly See 3 7 To Remove Door Use Kel Kem polish plus part 65 06 004...

Страница 86: ...compounds which can damage the burner materials and the ceramic glass Use of unpurified gas will void the warranty for this product 6 5 PILOT OUTAGE AND RE LIGHTING If ignition system goes into locko...

Страница 87: ...left side Care must be exercised not to pull or tug on this harness which may result in breakage of connection terminals on either end Convection Blower The convection blower is mounted on the firebox...

Страница 88: ...85 03 01107 FV34 DECOR Page 88 Gas Train Replacement Parts List Please contact your Mendota Dealer for parts availability and parts pricing...

Страница 89: ...on 1 HA 78 00287 Burner Assembly ITEM QTY PART NO DESCRIPTION 4 3 50 06 00130 SPACER FOR GROMMET 5 3 50 06 00129 GROMMET RUBBER 6 3 50 03 00067 NUT 10 24 KEPS ZINC PLATED 7 3 50 01 00156 HHSMS 8 18 X...

Страница 90: ...85 03 01107 FV34 DECOR Page 90 Accent Light Replacement Parts Figure 6 5 Accent Light Bulb Lens Installation Figure 6 6 Accent Light Lens Installation...

Страница 91: ...e on the gasket should contact the glass surface Use tracer lines in gasket to determine where the glass should sit on the gasket surface 4 Place glass and gasket assembly in glass frame and carefully...

Страница 92: ...Burner flames are stable and are not lifting off burner Inform owner that an initial curing step is required Read and follow Mendota Fireplace and Insert Curing Instructions found on unit and in owner...

Страница 93: ...rmal breakage only STD Stainless Steel Burner Tubes Ceramic Burners STD All Castings EXT STD Valve Assembly and all gas control components Pilot Assembly Flame Sensor Spark Electrode Pilot Tubing Orif...

Страница 94: ...ed to be defective prior to processing or authorizing of any claim Failure to allow this upon request will void the warranty All warranty claims must be submitted by the dealer servicing the claim inc...

Страница 95: ...covered under the terms of this warranty 14 Freight damages for products or parts are not covered under the terms of the warranty 15 Products made or provided by other manufacturers and used in conju...

Страница 96: ...register with Mendota to qualify for the Lifetime Limited Warranty within 30 days Product registration will activate your Lifetime Limited Warranty Owners should complete the forms available at mendot...

Страница 97: ......

Страница 98: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...

Отзывы: