![Mendota DXV-35 DEEP TIMBER II Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/mendota/dxv-35-deep-timber-ii/dxv-35-deep-timber-ii_installation-and-operating-instructions-manual_1770773039.webp)
38
HEARTH PAD
SURFACE
HEARTH PAD SURFACE MUST BE
FLUSH WITH FIREPLACE BOTTOM
IF INSTALLING THE WELLINGTON
OR DEERFIELD!!
Information specific to the installation of Millennia Flat Grills, Victoria Filigrees and Tuscany Filigrees
The Millennia Flat Grills, Victoria Filigree and Tuscany Fili-
gree are designed to be “inside-fit” trim kits. All of these trim
kits fit within the inner perimeter of the Fireplace’s Faceplate
and remain flush within the Faceplate’s front surface, see Fig-
ure below. This fitting method allows flexibility in covering
the black visible surface of the Faceplate with non-combustible
materials such as Tile, Marble, Slate, Stone and Brick; as long
as enough room is allowed for the removal of these Mendota
Designer Fronts and the glass door for servicing,
WARNING: COMBUSTIBLE MATERIALS
MUST NOT COVER THE FRONT SURFACE
OF THE FIREPLACE’S FACEPLATE.
Figure 11
Information specific to the installation of the
WELLINGTON FIRESCREEN FRONT:
The Wellington Fire screen Front is designed to be an “in-
side-fit” trim. The top and sides of these trim kits fit with-
in the inner perimeter of the Fireplace’s Faceplate. The
bottom member of this trim, however, overlaps the bottom
2” black boarder of the fireplace front faceplate. There-
fore, DO NOT COVER THE BOTTOM 2” BOARDER
OF THE FIREPLACE FACEPLATE WHEN
INSTALLING THE WELLINGTON FIRESCREEN
TRIM. The sides and top edges of the black visible sur-
face of the Faceplate may be covered with non-
combustible materials such as Tile, Marble, Slate, Stone
and Brick; as long as enough room is allowed for the re-
moval of this Mendota Designer Fronts
and the glass door for servicing,
Hearth Protection Pad Installation Information when planning
to install the Wellington Front and Deerfield Front.
If planning to install the Wellington Front, the hearth protection pad in-
stalled in front of the DXV-35 Fireplace must be designed, built and in-
stalled so that the hearth protection pad’s top surface is flush with the bot-
tom-most surface of the DXV35 Fireplace. See FIGURE 16.
Figure 13
DO NOT COVER THIS AREA OF THE FACEPLATE WHEN
INSTALLING THE WELLINGTON FIRESCREEN FRONT
O
N
LY
THE CROSS HATCHED AREA M
A
Y
BE CO
VERED
WITH NON
-COM
B
U
S
TIBLE
M
A
TERIAL
S WHEN INSTALLING
T
H
E
WELLI
N
G
TO
N FIRESCREEN F
R
O
N
T.
Figure 12
Содержание DXV-35 DEEP TIMBER II
Страница 24: ...23...
Страница 25: ...24...
Страница 26: ...25...
Страница 42: ...41 TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...