WARNING:        DO NOT OPERATE THIS APPLIANCE WITH THE GLASS 
REMOVED, CRACKED OF BROKEN.  REPLACEMENT OF GLASS 
SHOULD BE DONE BY A

 LICENSED OR QUALIFIED PERSON. 

MENDOTA 

GAS DIRECT VENT FIREPLACE  

WITH 

HEARTHGLO SEALED COMBUSTION SYSTEM 

Model DXV-35 TIMBER FIRE with Direct Rear Vent Option 

STANDARD FRONT                                                            BAY FRONT

 

 

INSTALLATION & OPERATING INSTRUCTIONS 

NO. TF-0616 

 

 

 

WARNING:  Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.  Refer to this manual.  For assistance 
or additional information consult a qualified installer, service agency or the gas supplier. 

 

FOR YOUR SAFETY: 
 
IF YOU SMELL GAS: 
 
1. OPEN 

WINDOWS. 

2. 

DO NOT TOUCH ELECTRICAL SWITCHES. 

3. 

DO NOT TRY TO LIGHT ANY APPLIANCE. 

4. 

EXTINGUISH ANY OPEN FLAME 

5. 

DO NOT USE THE PHONE IN YOUR BUILDING. 

6. 

IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S 
PHONE. 

7. 

FOLLOW THE GAS SUPPLIERS INSTRUCTIONS. 

8. 

IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE 
DEPARTMENT. 

 

 
FOR YOUR SAFETY 
 

  INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED 

INSTALLER, SERVICE AGENCY, OR THE GAS SUPPLIER.  DO NOT STORE 
OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE 
VICINITY OF THIS OR ANY OTHER APPLIANCE 

WARNING: 

MENDOTA GAS FIREPLACES ARE HEAT PRODUCING 
APPLIANCES.  DO NOT BURN WOOD, PAPER OR OTHER 
MATERIALS IN THE FIREPLACE.  THE FIREPLACE IS 
DESIGNED AS A SUPPLEMENTAL HEAT SOURCE. IT IS 
ADVISABLE TO HAVE AN ALTERNATE HEAT SUPPLY. 

 

 

WARNING:

  IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, 

 

 PERSONAL INJURY OR LOSS OF LIFE.  

 

 

IMPORTANT:  THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER! 

 

Содержание DXV-35 DEEP TIMBER II

Страница 1: ...4 EXTINGUISH ANY OPEN FLAME 5 DO NOT USE THE PHONE IN YOUR BUILDING 6 IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR S PHONE 7 FOLLOW THE GAS SUPPLIERS INSTRUCTIONS 8 IF YOU CANNOT REACH YOUR GAS...

Страница 2: ...________________________________________________________________19 RANDOM LOG INSTALLATION ____________________________________________________________________________22 TIMBERFIRE LOG SET INSTALLATI...

Страница 3: ...sting and certification agency to American National Standards Institute ANSI Gas Appliance Safety Standards The Mendota Gas DXV Fireplace has been tested and certified by Intertek Testing Services 843...

Страница 4: ...stallation repair and any adjustments to logs or burner must be done by a qualified service person The Fireplace should be inspected before use and at least annually by a professional service person M...

Страница 5: ...earances pg 12 and pg 22 Non combustible marble brick stone etc mantels or mantels with steel protector plate on underside can be installed at any desired height above upper grill Never block off uppe...

Страница 6: ...t Pipes AMERIVENT DURAVENT SELKIRK METALBESTOS SECURITY CHIMNEY brand pipes and venting components may be used when venting off the top Venting off the top on the DXV 35 Fireplace provides a large deg...

Страница 7: ...ff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG 3 5 kPa The proper gas line diameter must be selected to run from the supply regul...

Страница 8: ...place an additional inches to inches regulator must be installed for the Fireplace EXCEPTION Some codes allow 2 PSI 1 4KPA supplies to enter the residence in which case pounds to inches regulators are...

Страница 9: ...ffit located above the terminal from the center line of the terminal 18 inches 46 cm minimum Vinyl surfaces require 24 min K Clearance to a mechanical air supply inlet 6 feet 1 8 m minimum E Clearance...

Страница 10: ...nce Mendota Direct Vent Fireplaces and Stoves it is critical that the DuraVent GS and American Metals vent pipe sections are sealed tightly and leak proof This means that all pipe sections must be car...

Страница 11: ...ials may overlay nailing flanges and come in contact with the edges of the black front surface but may not overlay the 2 black front sur face Noncombustible material such as marble or brick can be ins...

Страница 12: ...ace Failure to follow all directions and failure to observe all restrictions and clearances can result in property damage bodily injury or can lead to death TOP VENTING REQUIRES AMERIVENT DURAVENT SEL...

Страница 13: ...45 angle to the front face and starting at the side edge of this appliance is allowed Projections behind this 45 angle edge shaded area are allowed R 1 RATED HEARTH PAD REQUIRED USE R 1 RATED BOARD A...

Страница 14: ...9 ATTIC INSULATION SHIELD 12 10 ROOF FLASHING 0 12 TO 6 12 10 ROOF FLASHING 7 12 TO 12 12 11 STORM COLLAR 12 VERTICAL VENT CAP 13 SUPPORT BAND 14 HORIZONTAL VENT CAP 15 FIRESTOP SPACER If adjustable...

Страница 15: ...MS NOTE FOR LP GAS HIGH ALTITUDE SEE PG 15 NOTE 9 MINIMUM RISE CAN BE USED IF NO HORIZONTAL VENT SECTIONS GREATER THAN 6 or 7 ARE USED ALL OTHER INSTALLATIONS MUST FALL WITHIN ABOVE SHADED AREA Figure...

Страница 16: ...45 COAX VENT 15 1 2 85 03 00531 For L P gas and high altitude installations above 4 000 ft 45 elbows must be used in place of 90 elbows NOTE This requires 19 minimum height to center CAUTION If 90 elb...

Страница 17: ...e center of where the vent pipe will penetrate the wall 3 Cut and frame a 9 wide x 10 high opening in the wall The hole must be positioned so the vent system will run level or have a rise AND be perpe...

Страница 18: ...2 PITCH 45 01 00202 FLASHING 6 12 12 12 PITCH 45 01 00203 STORM COLLAR 45 01 00204 ATTIC INSULATION SHIELD 45 01 00206 CO LINEAR APPLIANCE ADAPTOR 45 01 00207 CO LINEAR TOP KIT 45 01 00208 VERTICAL KI...

Страница 19: ...netrate the outside wall Since vent pipe sections overlap we suggest pre assembling and measuring the total vent pipe run so you can more accurately locate the point where the vent pipe will penetrate...

Страница 20: ...f in No 1 The opening should be a sufficient size to meet all clearance requirements Continue to assemble lengths of pipe and elbows necessary to reach up through the roof line Galvanized pipe and elb...

Страница 21: ...ent cap can be determined as follows H DIMENSION ROOF PITCH FEET METERS FLAT to 6 12 2 6 7 12 to 9 12 2 6 10 12 to 12 12 4 1 2 13 12 to 16 12 6 1 8 17 12 to 21 12 8 2 4 8 Complete installation with st...

Страница 22: ...frame 2 Pull Glass Latch Tool outward about 3 8 3 Rotate Glass Latch Tool 90 degrees 4 Slowly Release Glass Latch Tool 5 Remove Glass Latch Tool To Latch Glass Frame Latches reverse steps 5 to 1 above...

Страница 23: ...front surfaces of log for additional glow Add wool to burned out space between front logs Fill area to back burner WARNING Do not block holes with excessive wool Delayed ignition and sooting can occu...

Страница 24: ...23...

Страница 25: ...24...

Страница 26: ...25...

Страница 27: ...26 The following Check Off Lists must be completed prior to final operation of the Fireplace or manufacturer s warranty and liabilities will be voided...

Страница 28: ...leted Connect thermostat to gas valve terminals TPTH TH Use solid copper wire See page 40 for wires specifications System Millivolt readings must be taken by a qualified installer CAUTION Pilot flame...

Страница 29: ...2 hrs 9 Reinstall glass front screen by hanging slots on upper edge of door over tabs on upper edge of firebox opening Then swing in lower edge of door Carefully pull out the two 2 Spring Loaded Door...

Страница 30: ...in button firmly until unit lights DO NOT push button and release quickly before burner lights Burner should light IMMEDIATELY and then button can be released If unit does not light imme diately relea...

Страница 31: ...eration after servicing BLOWER OPERATION The Mendota DXV Fireplace is designed so the blower operates at all times the fireplace is operating The blower output can be regulated with the rheostat inclu...

Страница 32: ...e Flame Adjustment below Clean out carbon spider webs lint etc from shutter area Logs and burner NEVER BLOCK AIR INTAKE OR OUTLET VENTS Figure 9 Air Shutter GAS FLAME ADJUSTMENT Be sure burner and log...

Страница 33: ...xterior glass may be cleaned with cleaner as desired Inte rior glass use soap and water CAUTION Do Not use oven cleaner to clean glass NOTE Additives that are put in gas both natural and propane to ma...

Страница 34: ...LATION check off lists are completed see pg 39 2 COMBUSTION SYSTEM MILLIVOLT READING Millivolt readings must be taken by a qualified installer at the time of installation and after any interruption in...

Страница 35: ...esired Interior glass use KEL KEM Polish Plus part 65 06 00455 or comparable product Do Not use oven cleaner or abrasive cleaners to clean glass DO NOT CLEAN WHEN GLASS IS HOT 4 PERIODIC VISUAL CHECK...

Страница 36: ...t 2 Install pilot orifice 05 04 00036 014 see pg 45 for location Remove and install pilot hood with 7 16 open end wrench Pilot orifice thimble is located inside pilot hood base 3 Install the new LP Pr...

Страница 37: ...AT 35 01 00275 FIREBRICK KIT 15 02 00062 BLOWER ASS Y HA 30 00230 VALVE ASS Y SIT 15 02 00064 R H BLOWER WITH MOTOR 05 02 00306 VALVE NAT GAS 15 02 00065 L H BLOWER WITH MOTOR 05 01 00157 THERMO DISC...

Страница 38: ...in the diagram below Any material that protrudes into this area on the sides top or bottom edges can only be flush with the front surface of the fireplace faceplate If planning to install either the...

Страница 39: ...The top and sides of these trim kits fit with in the inner perimeter of the Fireplace s Faceplate The bottom member of this trim however overlaps the bottom 2 black boarder of the fireplace front face...

Страница 40: ...re low in w c 1 7 3 6 Minimum Inlet Pressure in w c 5 0 11 0 _______________________________________________ This appliance is equipped for installation at 0 610 meters This appliance must be installe...

Страница 41: ...ARANCES TO COMBUSTIBLES VENT LOCATIONS Per Manual INSTALL PROPER SIZE GAS LINES CHECK FOR GAS LEAKS Per Manual CHECK FOR CORRECT GAS PRESSURE AT MANIFOLD Per Manual a 3 5 Inches Water Column Maximum N...

Страница 42: ...41 TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED...

Страница 43: ...erformance of any part of this limited warranty Mendota has the right to investigate and inspect the exact original Fireplace and entire installation without any alterations or tampering in the event...

Страница 44: ...Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Mendota Hearth Division WEBPAGE www johnsongas com or www mendotahearth com Part 85 03 00686...

Отзывы: