85-03-01071
D30 DEEP TIMBER
Page
18
Fireplace insert Features
EXTERNAL DIMENSIONS
: 30-1/2
”
Wide X 19
”
High X 16-1/2
” Deep
GLASS SIZE
: NeoCeram Glass with non-reflective coating. Visible Glass measures 26-7/16
” X
11-1/8
”.
MANTEL ALLOWANCE
: 8” Deep Mantel at
12
” Above Top Convection
Opening (32-7/16
” up from base of Unit)
CONTROLS
: Thermocouple Safety System with Standing Pilot Thermopile power generator. Thermostat option available.
BLOWER SYSTEM
: 190 CFM Dual Blower System. 120VAC, 2Amps. Dedicated Hot Power only. No switches, Fan Speed Controls
or Light Dimmers are allowed in same circuit.
BURNER SYSTEM
: Stainless-Steel Tubular burners.
BURNER AIR SHUTTER SYSTEMS
: Externally controllable Burner air shutter.
LOG SET
: 6-piece, Premium Fiber Log Set with Extreme glow and realism.
REFRACTORY PANELS
: High Detail Red Clinker Fiber Brick Panels included. Brick Panels required for operation.
NATURAL GAS INFORMATION
: Factory equipped for Natural Gas.
4.5” WC
Minimum inlet pressure required.
LPG INFORMATION: LP conversion kit #
HA-28-00194 is required. 12
” WC
Minimum inlet pressure required. For the D30 LPG
application, the orifice is to be drill size #52. For higher altitude, adjustment to orifice size may be necessary.
Содержание D40 DEEP TIMBER
Страница 2: ...85 03 01071 D30 DEEP TIMBER Page I...
Страница 15: ...85 03 01071 D30 DEEP TIMBER Page 15 Figure 3 10 Figure 3 9...
Страница 36: ...85 03 01071 D30 DEEP TIMBER Page 36 Blower System Wiring Diagram Figure 3 38 BLOWER SYSTEM WIRING DIAGRAM...
Страница 81: ......
Страница 82: ...Johnson Gas Appliance Company 520 E Avenue NW Cedar Rapids Iowa 52405 Mendota Warranty Registration...