7 of 28
Log Length
Wood Reload
Weight Wood Load
Smokeless brique�ed
fuel Reload
Weight (
Smokeless
brique�ed fuel
)
Loxton 5 DC
35cm
1hr
1.2kg
2hr
1.5kg
STOVE PERFORMANCE & TESTING
Combus�ble materials should not be located where the heat dissipa�ng through the walls of fireplaces or flues
could ignite it. Therefore when installing the stove in the presence of combus�ble materials due account must
be taken of the guidance on the separa�on of combus�ble material given in Building regulations Approved
Document J and also in these stove instructions. The minimum distances to flammable materials are specified
on the EN 13240 plate on the back of the stove. When installing the stove 100mm from a combus�ble wall
behind , use the additional, top flue rear convection panel supplied with the stove, this slots over the rear
convection panel providing additional radiant protection from the flue collar.
A twin wall insulated flue should
be fi�ed flush to the flue collar for this type of installa�on
.
Weight & Nominal Heat Output for Wood and Smokeless Fuels
Mendip Stoves, Loxton Dual Control 5kW models are tested in accordance with EN 13240.
300
1
0
0
158
20°
6
0
0
3
6
2
A DIAGRAM TO
ILLUSTRATE THE
MINIMUM DISTANCE
TO COMBUSTIBLE
MATERIALS
350
75
250mm when fi�ed
with flat convection
panel
THE MINIMUM DISTANCE TO COMBUSTIBLE MATERIAL
Distance to
Combus�bles
Rear
Side
Side
Flat convec�on
panels
Logs placed in
logstore
Corner posi�on
12mm non-
combus�ble
floor plate
Loxton 5 DC
75mm
350mm
N/A
N/A
N/A
YES
Loxton 5 DC
Convec�on
75mm
N/A
250mm
N/A
150mm
YES
Loxton5 DC
Convec�on
Logstore
75mm
N/A
250mm
Yes, convector
panel supplied
with log base
150mm
YES
0.08%
76.5%
17
135
61
4.9 kW