Product Overview
Page 13
Mechanical Specifications
Dimensions
-
3U, 4 HP (four DisplayPort interfaces), or
-
3U, 8 HP (six DisplayPort interfaces)
Weight
-
approx. 260 g (with heat sink)
Environmental Specifications
Temperature range (operation):
-
0°C to +60°C
-
-50°C to +85°C screened (model 02G514-01)
-
Airflow: min. 1.0 m/s
Temperature range (storage): -40°C to +85°C
Cooling concept
-
Air-cooled, or
-
Conduction-cooled in MEN CCA frame
Relative humidity (operation): max. 95% non-condensing
Relative humidity (storage): max. 95% non-condensing
Altitude: -300 m to +3000 m
Shock: 15 g, 11 ms (EN 60068-2-27)
Bump: 10 g, 16 ms (EN 60068-2-29)
Vibration (sinusoidal): 1 g, 10 Hz - 150 Hz (EN 60068-2-6)
Conformal coating; optional
Reliability
MTBF: 911 603 h @ 40°C according to IEC/TR 62380 (RDF 2000) (model 02G214-00)
Safety
Electrical Safety
-
Information technology equipment: EN 60950
Flammability (PCBs)
-
UL 94 V-0
EMC
EN 55022 (radio disturbance)
IEC 61000-4-2 (ESD)
IEC 61000-4-3 (electromagnetic field immunity)
IEC 61000-4-4 (burst)
IEC 61000-4-5 (surge)
IEC 61000-4-6 (conducted disturbances)
IEC 61000-4-8 (power frequency magnetic field)
IEC 61000-4-11 (voltage dips)