background image

 

 

 
 

AT3550 User Guide V1.00 

February 11, 2005 

page 5 of 16 

 

3.1.4 CONNECTOR 

The drive may be interfaced directly to a standard 3.5”, 0.1in IDE socket connector 
or a standard 40pin IDE ribbon and AT power cable.  See drawing below for pin 1 
location.  Care should be taken when installing the AT3550 into the system, as 
misalignment can permanently damage the drive interface connector or 
electronics. 

 

Figure 1 - Drive Connector 
 
 

3.1.5 MOUNTING 

The AT3550 may be mounted in any orientation.  A total of four bottom and six 
side mounting holes are available for installation.  The mounting holes require 6-
32 screws with a maximum depth of 0.25 inch. 
 
The diagram given below is valid for all capacities of the AT3550 drive.  The 
overall outside dimensions are 4 inches (101.7 mm) wide, 5.75 inch  (146.05mm) 
long, and 0.630 inch (16mm) tall.  Please refer to the following drawing for 
dimensions and mounting hole locations. 

 

The diagram given below is for a 12 Gbyte drive.  Drives with higher capacities will 
be 0.760 inches (19.3mm) or taller.  All other dimensions remain identical. 
 
 
 

 
 
 
 
 
 

Содержание AT3550 Wolverine

Страница 1: ...3 5 Wolverine 3 5 IDE Solid State Flash Drive User Guide 80 03 00035 Revision 1 1 February 11 2005 Memtech SSD Corporation 7628 Las Positas Road Livermore CA 94550 925 294 8483 800 445 5511 www memte...

Страница 2: ...ERATION 11 4 1 ACTIVE REMAP AND WRITE LIMITATIONS 11 4 2 ECC 11 4 3 POWER 12 4 4 TROUBLE SHOOTING GUIDE 13 5 MAINTENANCE 13 6 SPECIFICATIONS 14 6 1 INTERFACE 14 6 2 PERFORMANCE 14 6 3 ENVIRONMENTAL 14...

Страница 3: ...tal conditions Sector Erasable NAND E 2 PROM Flash is used to provide over 60 Gbytes of nonvolatile solid state storage in an extremely small rugged form factor The drive is 100 IDE compatible and req...

Страница 4: ...diagrams given in Section 3 2 The default configuration is for a single drive system or as the master in a two drive system Change the configuration as required Never attempt to change the jumpers wh...

Страница 5: ...UNTING The AT3550 may be mounted in any orientation A total of four bottom and six side mounting holes are available for installation The mounting holes require 6 32 screws with a maximum depth of 0 2...

Страница 6: ...7 PARTITION The drive must be partitioned using the system s FDISK utility For operating systems other than DOS please refer to your OS operating guides Note that changing the partition information wi...

Страница 7: ...r drive If the drive is to be a Slave device drive D install the jumper ion the SL location This jumper is part of the unitized ATA interface header and is on 0 1 inch centers This location is factory...

Страница 8: ...WP OPT1 OPT2 TX LED RX XP GND Jumper Header J2 3 2 6 WRITE PROTECT The WP jumper on header J2 is used to write protect the drive The default position of this jumper is OFF Installing the WP jumper in...

Страница 9: ...ts on this line as internal damage to the drive may result The two outside pins on the header are used to connect power to the holdup circuit A third pin is needed to connect the grounds of the drive...

Страница 10: ...s the 40 pin 0 1 inch signal cable interface pin out PIN SIGNAL PIN SIGNAL 1 RESET 2 GND 3 DATA7 4 DATA8 5 DATA6 6 DATA9 7 DATA5 8 DATA10 9 DATA4 10 DATA11 11 DATA3 12 DATA12 13 DATA2 14 DATA13 15 DAT...

Страница 11: ...s the device s useful life almost 100 fold and makes the Memtech series of Solid State Drives suitable for both read mostly and read write applications In an ongoing effort to determine the durability...

Страница 12: ...outside of these limits is not guaranteed Note that the drive will operate down to 4 volts but reliability issues such as Uncorrectable Errors or invalid data reads may occur An on board voltage moni...

Страница 13: ...uring a write command or as been run under marginal or dirty power conditions uncorrectable errors may be introduced into the media This may result in data read errors a corrupted FAT table entry or d...

Страница 14: ...Transfer Rate 5 0 Mbytes sec sustained Burst Transfers 66 Mbytes sec 6 3 ENVIRONMENTAL Commercial Temperature Range Operating 0 o to 70 o C Storage 65 o C to 125o C Extended Temperature Range E Opera...

Страница 15: ...th 18 inches 460 mm Rec Cable Length 12 inches 305 mm Weight 4 Gbytes 7 9oz 246g 6 6 RELIABILITY 6 6 1 ERROR CORRECTION A programmable 96 bit Reed Solomon Error Correction and Detection capable of cor...

Страница 16: ...ects in material and workmanship for the life of the drive The warranty is void in the case of misuse accident alteration improper installation misapplication or the result of unauthorized service or...

Отзывы: