![Memorex MVT2194 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/memorex/mvt2194/mvt2194_service-manual_1770145025.webp)
WHEN REPLACING EEPROM (MEMORY) IC
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
NOTE: No need setting for after INI 35 due to the adjustment value.
08
0A
70
69
C2
B3
24
A9
51
2C
+0
+1
+2
+3
+4
+5
+6
+7
+8
+9
+A
+B
+C
+D
+E
+F
INI
B2
92
93
00
11
00
05
08
82
40
A6
00
40
00
10
00
10
9A
A9
0F
94
45
06
14
Table 1
1.
2.
Enter DATA SET mode by setting VOLUME to minimum.
While holding down VOLUME button on front cabinet, press key 6 on remote control.
ADDRESS and DATA should appear as FIG 1.
Fig. 1
INIT 00 08
POWER ON 0010
PLAY/REC 0003
ADDRESS DATA
3.
4.
5.
6.
7.
8.
9.
10.
11.
The unit will now have the correct DATA for the new MEMORY IC.
ADDRESS is now selected and should "blink". Using the SET +/- button on the remote, step through the ADDRESS until
required ADDRESS to be changed is reached.
Press ENTER to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using SET +/- button until required DATA value has been selected.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
Repeat steps 3 to 6 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
After the data input, set to the initializing of shipping.
Turn POWER on.
While holding down VOLUME button on front cabinet, press key 1 on remote control.
After the finishing of the initializing of shipping, the unit will turn off automatically.
06
3A
01
25
54
60
23
3B
DA
D7
20
00
00
00
00
00
38
88
08
88
98
88
04
---
---
---
---
30
---
---
---
---
---
---
C4-1