ELECTRICAL ADJUSTMENTS
D3-1
2-1: PG SHIFTER
1.
2.
3.
4.
Connect CH-1 on the oscilloscope to TP1002 and CH-2
to J4202.
Playback the alignment tape. (JG001A)
Press and hold the Tracking-Auto button on the remote
control more than 2 seconds to set tracking to center.
Press the VOL. DOWN button on the set and the
channel button (3) on the remote control simultaneously
until the indicator REC disappears. If the indicator REC
disappears, adjustment is completed.
(If the above adjustments doesn't work well:)
5.
6.
7.
Press the VOL. DOWN button on the set and the
channel button (3) on the remote control simultaneously
until the indicator REC disappears.
When the REC indicator is blinking, press both VOL.
DOWN button on the set and the channel button (4) on
the remote control simultaneously and adjust the
Tr/- button until the arising to the down of Head
Switching Pulse becomes 6.5 ± 0.5H.
(Refer to Fig. 2-1-A, B)
Press the Tracking Auto button.
CH-1
CH-2
6.5H
Fig. 2-1-A
Fig. 2-1-B
CH-2
CH-1
6.5H
2. BASIC ADJUSTMENTS
(VCR SECTION)
1. BEFORE MAKING ELECTRICAL
ADJUSTMENTS
Read and perform these adjustments when repairing the
circuits or replacing electrical parts or PCB assemblies.
CAUTION
•
•
•
•
Use an isolation transformer when performing any
service on this chassis.
Before removing the anode cap, discharge electricity
because it contains high voltage.
When removing a PCB or related component, after
unfastening or changing a wire, be sure to put the wire
back in its original position.
When you exchange IC and Transistor for a heat sink,
apply the silicon grease (YG6260M) on the contract
section of the heat sink, Before applying new silicon
grease, remove all the old silicon grease. (Old grease
may cause damages to the IC and Transistor.)
On-Screen Display Adjustment
1.
2.
Unplug the AC plug for more than 5 seconds to set the
clock to the non-setting state.Then, set the volume
level to minimum.
Press the VOL. DOWN button on the set and the
Channel button (9) on the remote control simultaneously
to appear the adjustment mode on the screen as shown
in Fig. 1-1.
Fig. 1-1
3.
4.
FUNCTION
OSD H
CUT OFF
RF DELAY
VIF VCO
H VCO
H PHASE
V SIZE
V SHIFT
R DRIVE
B DRIVE
R BIAS
G BIAS
B BIAS
NO.
00
01
02
03
04
05
06
07
08
09
10
11
12
Fig. 1-2
FUNCTION
BRIGHTNESS
CONTRAST
COLOR
TINT
SHARPNESS
FM LEVEL
LEVEL
SEPARATION 1
SEPARATION 2
TEST MONO
TEST STEREO
X-RAY TEST
NO.
13
14
15
16
17
18
19
20
21
22
23
24
TV
00 OSD 15
Use the Channel UP/DOWN button or Channel button
(0-9) on the remote control to select the options shown
in Fig. 1-2.
Press the MENU button on the remote control to end
the adjustments.
2-2: VCO FREERUN
1.
2.
3.
4.
Place the set with Aging Test for more than 10 minutes.
Connect the digital voltmeter between the pin 7 of
CP602 and the pin 1 (GND) of CP602.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (03) on the remote control to
select "VIF VCO".
Press the VOL. UP/DOWN button on the remote control
until the digital voltmeter is 2.5V.