ELECTRICAL ADJUSTMENTS
2-11: SEPARATION 1, 2
Please do the method (1) or method (2) adjustment.
Method (1)
1.
2.
3.
4.
5.
Set the multi-sound signal generator for each different L-ch
and R-ch frequency (Ex. L-ch=2KHz, R-ch=400Hz)
and receive the RF.
Connect the oscilloscope to the pin 6 and pin 7 of CP601.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (26) on the remote control to
select “SEP 1”.
Press the VOL. UP/DOWN button on the remote control
to adjust it until the audio output wave becomes a fine
sine wave.
Press the CH UP button once the set to “SEP 2” mode.
Then perform the above adjustment 4.
Method (2)
1.
2.
3.
4.
5.
6.
7.
8.
9.
Set the multi-sound signal generator L-ch=1KHz, R-ch
=Non input and receive the RF.
Connect the oscilloscope to the pin 6 and pin 7 of CP601.
Press the AUDIO SELECT button on the remote control
to set to the stereo mode.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (26) on the remote control to
select “SEP 1”.
Press the VOL. UP/DOWN button on the remote control
to adjust it until the R-ch output becomes minimum.
Set the multi-sound signal generator L-ch=Non input,
R-ch=1KHz and receive the RF.
Connect the oscilloscope to the pin 6 and pin 7 of CP601.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (27) on the remote control to
select “SEP 2”.
Press the VOL. UP/DOWN button on the remote control
to adjust it until the L-ch output becomes minimum.
The output difference of the between with Filter and
without Filter should be more than 20db for both L and R.
2-9: HORIZONTAL PHASE
1.
2.
3.
4.
Receive the monoscope pattern.
Using the remote control, set the brightness and contrast to
normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (05) on the remote control to
select “H.PHASE”.
Press the VOL. UP/DOWN button on the remote control
until the SHIFT quantity of the OVER SCAN on right and
left becomes minimum.
2-6: VERTICAL SIZE
1.
2.
3.
4.
Receive the monoscope pattern.
Using the remote control, set the brightness and contrast
to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (06) on the remote control to
select “V. SIZE”.
Press the VOL. UP/DOWN button on the remote control
until the SHIFT quantity of the OVER SCAN on upside
and downside becomes 9
±
2%.
2-7: VERTICAL LINEARITY
NOTE: Adjust after performing adjustments in section 2-6.
After the adjustment of Vertical Linearity, reconfirm
the Vertical Position and Vertical Size adjustments.
Receive the monoscope pattern.
Using the remote control, set the brightness, contrast,
to normal position.
Adjust the VR402 until the SHIFT quantity of the OVER
SCAN on upside and downside becomes minimum.
1.
2.
3.
2-8: LEVEL
1.
2.
3.
Connect the AC voltmeter to pin 6 of CP601.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (25) on the remote control to
select “LEVEL”.
Press the VOL. UP/DOWN button on the remote control
until the AC voltmeter is 80
±
2mV.
1.
2.
3.
4.
5.
6.
7.
2-10: CONTRAST MAX
Receive an over 70dB color bar pattern. (RF Input)
Using the remote control, set the brightness and
contrast to normal position.
Activate the adjustment mode display of Fig. 1-1 and
press the channel button (17) on the remote control
to select "CONT MAX".
Press the VOL. UP/DOWN button on the remote
control until the contrast step No. becomes "70".
Receive a broadcast and check if the picture is normal.
Receive the color bar pattern. (Audio Video Input)
Press the TV/VIDEO button on the remote control to
set to the AV mode. Then perform the above
adjustments 2~5.
2-12: OSD POSITION
1.
2.
Activate the adjustment mode display of Fig. 1-1.
Press the VOL. UP/DOWN button on the remote
control until the difference of A and B becomes
minimum. (Refer to Fig. 2-2)
B
A
TV
00 OSD 10
Fig. 2-2
D-2
Содержание MT2274A
Страница 31: ...M3T1 09D O R NO SPEC NO W523015 ...