INSTALLATION AND SERVICE INSTRUCTION
- 6 -
CAUTION:
Use an isolation transformer when performing any service on this chassis.
SHUTDOWN CIRCUIT:
When the high voltage rises, there are simultaneous voltage increase
developed at terminal 6 of the Horizontal Output Transformer ( T671 ) and applied to pin 29 of IC301. If
excessive high voltage is produced, the increased voltage developed exceeds the rating of zener diode
D552 causing the Horizontal Oscillator to stop functioning and the high voltage system to shut down.
AFT ( AUTOMATIC FINE TUNING ) ADJUSTMENT
1. Connect TV Test Pattern Generator (NTSC signal, Monoscope signal, 70dBu, channel 2) to EXT.
Antenna Terminal (TE1) through TV Channel Signal Generator.
2. Connect wire (+) of DC Digital Voltmeter to TP6 and wire (-) to TP4. (Figure 1)
3. Adjust T202 so that the DC Digital Voltmeter reading is 2.0V
±
0.1V.
FIG. 1
SUB COLOR AND SUB TINT ADJUSTMENT
1. Connect TV Test Pattern Generator (NTSC signal, Color Bar signal, 70dB u , channel 6) to EXT.
Antenna Terminal (TE1) through TV Channel Signal Generator.
2. Connect positive lead of Oscilloscope to TP14 and negative lead to TP10.
3. Set Tint control to center position. (by Remote Control).
( NOTE: For steps 4, 5 and 6 below, refer to page 3 for Adjustment By Remote Control Method).
4. Go to Adjustment Mode (1) by remote control.
5. Select SUB COLOR and SUB TINT from Adjustment Mode (1) menu screen.
6. Adjust SUB COLOR and SUB TINT level (by using + or - button on remote control) so that waveform 1
& 4 (for SUB COLOR) and waveform 2 & 3 (for SUB TINT) is the same as shown in Figure 2.
FIG. 2
Содержание MT1130C
Страница 10: ...TEST POINT 11 ...