Maintenance
Do not allow the fog liquid to become contaminated. Always replace the caps
on the fog liquid container and the fog liquid tank immediately after filling.
After every 40 hours of continuous operation, it is recommended to run a
cleaning solution composed of 80% distilled water/20% white vinegar through
the system to prevent the accumulation of particulate matter in the heating
element. The recommended cleaning regimen is as follows:
1. While unit is unplugged and cool, unscrew nozzle at very front of unit and
clean out debris with vinegar and a pipe cleaner, making sure that the hole
is free of clogs.
2. Empty all fog fluid from machine. Add cleaning solution to tank. Plug unit in
and begin warm up.
3. Run unit in a well-ventilated area unit tank is empty.
4. Replace
nozzle.
5. Cleaning is completed. Refill with fog liquid.
Cleaning your foggy regularly will help reduce costly parts replacement and repair
charges.
Save these instructions
MKA310
Specifications
Power
: 120V~, 60Hz
Heater :
700W
Fuse
: 125Va.c./F7A
Warm-up time : 4 minutes
Output : 25 ml / min
Tank Capacity : 0.86 liter
Dimensions : 340 x 200 x 200 mm
Weight
: 2.5 kg
-Only use with fog liquid –