background image

MEMOLUB® PLCD (PLC)

 

Lubricant dispenser

www.memolub.com 

7

 

 

 

 

Replacing the lubricant cartridge

 

 

 

Hazard and 
safety 
instructions

 

 Attention! The red 

casing bottom 
part contains a 
pressurized 
spring. Do not 
open! 

 

 
 
 
 

 

   

 

 

 

  Leq < 70 dB 

 Employ 

MEMOLUBs only 
for the lubrication 
of machines. 

 Use  only  with 

original 
cartridges. 

1. Unscrew MEMOLUB® (1)
from MEMO (2). MEMO 
remains screwed to the 
point of application. 

 

2. To open, place the 
lubricator on a flat surface. 
Press the hood downward 
and turn the black ring 
counterclockwise. 

3. Remove the label from 
the replacement cartridge. 
Enter the start date and the 
exchange date. 

   

 

   

 

   

 

 

 

 

 

 

4. Press the air 

carefully out of the 
cartridge. 

5. Set the cartridge on 
the casing. 

 

4. Carefully remove the 
cover of the cartridge. 
Place the casing upside-
down on the cartridge. 

5. Turn the casing over 
together with the cartridge. 

 

Only for grease cartridges

 

 

Only for oil cartridges

 

   

 

 

 
 

 

 

 
 

 

 

  6. Put the hood over 

the assembled casing 
and the cartridge. 

7. Press the hood 
downward and turn the 
black ring clockwise. 

 

8. Screw the 
MEMOLUB® onto the 
MEMO. 

Note: If necessary, 
prepare the MEMOLUB® 
with a manual grease 
gun 