1 Insert the plug straight into the receptacle,
until a
‘click’ is heard.
NOTICE:
The plug and its flexible
cable must not exert constraint on the receptacle.
2
Pull on the plug to make sure it is properly
latched in the receptacle.
A small rotation of the
plug, in either direction, allows the locking finger of the
receptacle to prevent any further rotation.
3 To close the pilot circuit,
turn the ring of the receptacle
up to the stop towards “1”
.
Check the continuity of the pilot.
Do not attempt to turn the ring toward “1” when
there is no plug engaged. Defeating the mechanical
lock could create a potentially hazardous or explosive
condition if energized under load.
4 To open the pilot circuit and unlock the plug,
turn
the ring back to “0” up to the stop
. Press on the
button to release the plug. The caps must then be
re-assembled on both sides.
MAINTENANCE
Before inspecting, repairing, or
maintaining MELTRIC products,
disconnect electrical power to the receptacle to eliminate
the risk of electrical shock. Rules applying to products
for use in explosive atmospheres impose that any
replacement of component must be performed under
the control of the manufacturer: MELTRIC Corporation.
MELTRIC products require little on-going maintenance.
However, it is a good practice to periodically perform
the following general inspections:
• Check the mounting screws for tightness.
• Verify that the weight of the cable is supported
by the strain relief mechanism and not by the
terminal connections.
• Check the IP gaskets for wear and resiliency.
Replace as required.
• Verify the electrical continuity of the ground circuit.
• Check the contact surfaces for cleanliness
and pitting.
Use a clean cloth to rub off deposits of dust or similar
foreign materials on the contacts and the plug interiors.
Sprays should not be used, as they tend to collect dirt.
If any significant pitting of the contacts or other serious
damage is observed, the device should be replaced.
Any repair or service must be achieved with genuine
TM
parts only.
MANUFACTURER’S RESPONSIBILITY
MELTRIC’s responsibility is strictly limited to the
repair or replacement of any product that does not
conform to the warranty specified in the purchase
contract. MELTRIC shall not be liable for any
penalties or consequential damages associated with
the loss of production, work, profit or any financial loss
incurred by the customer.
MELTRIC Corporation shall not be held liable when
its products are used in conjunction with products not
bearing the
TM
technology trademark. The
devices that are not marked with the
TM
technology trademark shall void all warranties on
the product.
MELTRIC Corporation is an ISO 9001 certified company. Its
products are designed, manufactured and rated in accordance
with applicable UL, CSA and IEC standards. MELTRIC designs
and manufactures its products in accordance with Marechal key-
ing standards established to ensure intermatablility with similarly
rated products manufactured by Marechal Electric Group.
INSSPEX E
WARNING
DANGER
CAUTION
NOTICE
ADVERTENCIA
DANGER
CAUTION
AVISO
WARNING
DANGER
CAUTION
NOTICE
ADVERTENCIA
DANGER
CAUTION
AVISO
MARECHAL ELECTRIC S.A.S. au capital de 5 341 400 € - SIRET 552 149 577 00058 - NAF 2733Z – N° TVA FR16552149577
5, avenue du chemin de Presles 94410 Saint-Maurice FRANCE - +33 (0)1 45 11 60 00 -
Déclaration UE de Conformité
EU Declaration of Conformity
Nous /
We
MARECHAL ELECTRIC S.A.S.
5, avenue de Presles
F-94417 SAINT-MAURICE Cedex – France
Tel :
+33 (0)1 45 11 60 00
Fax :
+33 (0)1 45 11 60 60
E-mail : [email protected]
Déclarons sous notre seule responsabilité que le produit /
Declare under our sole responsibility that the product
:
Connecteur unipolaire de puissance /
Single-pole power Connector
Type
Type
Marquage
Marking
Caractéristiques d’étanchéité
Watertightness characteristics
Conforme aux normes suivantes
Complies with the following standards
SPeX
II 2 G D
Ex e IIC T
Gb, Ex tb IIIC T
Db
LCIE 07 ATEX 6073 X
IP65/IP66
EN IEC 60079-0 : 2018(*)
EN 60079-7 : 2015 (*)
EN 60079-31 : 2014 (*)
Intensité /
Current
A
Section /
Section
mm²
GAZ /
GAS
POUSSIERES /
DUST
Classe de température pour /
Temperature class for:
Température de surface /
Surface temperature for:
-20°C ≤ Ta ≤ + 40°C
-20°C ≤ Ta ≤ + 60°C
-20°C ≤ Ta ≤ + 40°C
-20°C ≤ Ta ≤ + 60°C
235
70
T6
T5
T56°C
T76°C
290
T5
/
T56°C
/
335
95
T6
T5
T56°C
T76°C
415
T5
/
T56°C
/
376
120
T6
T5
T56°C
T76°C
456
T5
/
T56°C
/
415
150
T6
T5
T56°C
T76°C
493
T5
/
T56°C
/
450
185
T6
T5
T56°C
T76°C
530
T5
/
T56°C
/
497
240
T6
T5
T56°C
T76°C
570
T5
/
T56°C
/
584
T5
T4
T59°C
T79°C
540
300
T6
T5
T56°C
T76°C
620
T5
/
T56°C
/
600
400
T6
T5
T56°C
T76°C
680
T5
/
T56°C
/
(*)
:
Une étude comparative des normes: EN 60079-0 (versions 2018, 2012 + A11:2013 et 2009), EN 60079-7 (2007 et 2015) et EN 60079-31 (2014 et 2009) montre que le matériel
n’est pas concerné par les modifications substantielles.
A comparative study of the standards: EN 60079-0 (version 2018, 2012 + A11: 2013 and 2009), EN 60079-7 (2007 and 2015) and EN 60079-31 (2014 and 2009) shows that
the products are not concerned by the substantial modifications.
Satisfont aux dispositions des Directives du Conseil n° :
2014/34/UE du 26 février 2014 (ATEX)
2011/65/UE + amendement n°2015/863 du 31/03/2015 (RoHS)
Satisfy the measures set in the Council Directives n°:
2014/34/EU dated February 26, 2014 (ATEX)
2011/65/EU + amendment no 2015/863 dated 2015/03/31 (RoHS)
N° de notification de l’évaluation relatif à la qualité : LCIE 00 ATEX Q 8001 selon l’Annexe IV réalisé par l’organisme notifié n° 0081 :
LCIE – 33, avenue du Général Leclerc – 92260 Fontenay-Aux-Roses – France
Quality Assessment Notification Number: LCIE 00 ATEX Q 8001 according to Annex IV carried out by Notified Body N° 0081:
LCIE – 33, avenue du Général Leclerc – 92260 Fontenay-Aux-Roses – France
Saint-Maurice, 2019-10-25
Anne LE GUENNEC
Responsable Produits Ex /
Manager of Ex-Proof Product