InfiniBand Switch Platform Hardware User Manual
Mellanox Technologies
63
2.1.3.3 Spine to Leaf IB Connection Status LEDs
The leaf connection status on each spine displays the condition of the connection
between the spine and each leaf. There is a minimum of one LED per leaf per spine and a
maximum of 2 LEDs per leaf. These LEDs indicate a valid connection between a leaf
and a spine.
Table 8 shows the leaf to spine status according to the LED condition.
2.1.3.4 Bad Port LED
The Bad Port indicator is located on the left side of the spine. The following Bad Port
conditions are possible:
This LED shows symbol errors. Possible causes for this are:
•
bad cable
•
bad connection
•
bad connector
This LED lights up when one or more ports is receiving a symbol error. The LED imme-
diately goes off until the next symbol error is received.
2.1.3.5 UID LED Switch Identifier
The UID LED is a debug feature that will become available to customers in the near
future. For details please contact Mellanox Technologies support.
2.1.4
Spine Side Panel Display LED Indicators
The spine side panel display has LEDs that show the chassis condition.
Figure 58: Spine Side Panel Display Status Indications
Table 8 - Spine to Leaf IB Link Status
LED Condition
LED Description
Off
Link is down
Solid Green
Logical connection
Flashing Green
Data activity
Solid Orange
Physical connection
Table 9 - Bad Port LED Configurations
LED Condition
Description
Off
OK – No ports have received symbol errors recently
Flashing Orange
Error – One or possibly more ports has just received a
symbol error.
Содержание SX6518
Страница 2: ...Document Number 3805 Mellanox Technologies 2...
Страница 91: ...InfiniBand Switch Platform Hardware User Manual Mellanox Technologies 91 5 6 7 8 9 10 11 45 C 113 F 8 3 PSU...
Страница 109: ...InfiniBand Switch Platform Hardware User Manual Mellanox Technologies 109 4 5 6 7 8 9 10 45 C 113 F 8 3...
Страница 110: ...InfiniBand Switch Platform Hardware User Manual Mellanox Technologies 110 11 12 InfiniBand 13 14 15 16 17 InfiniBand...