Interfaces
79
Mellanox Technologies
3.1.3.2 Bad Port LED
The Bad Port LED is located on the left side of the leaf. The following Bad Port LED conditions
are possible.
Table 8 - Bad Port LED Configurations
LED Condition
Description
Off
OK: All ports are up and running
Amber: Flashing
Error: One or possibly more ports has just received a symbol
error
This LED shows symbol errors. Possible causes for this are:
• bad cable
• bad connection
• bad connector
This LED lights up when one or more ports is receiving a symbol error. The LED immediately
goes off until the next symbol error is received.
3.1.3.3 UID LED Switch Identifier
The UID LED is a debug feature that will become available to customers in the near future. For
details please contact Mellanox Technologies support.
3.1.3.4 Leaf Module Port Connector LED Assignment
Above the ports are two LEDs one for the upper port and one for the lower port . Each port
has a single 2 color LED.
presents the link status according to the LED condition.
Table 9 - Connector Physical and Logical Link Indications
LED Condition
Description
Off
No power to the port
Green: Solid
Logical link up
Green: Flashing
Data activity: Flashing frequency is proportional to data transfer
speed
Amber: Solid
Physical link up
Amber: Flashing
A problem with the physical link
The LED indicator, corresponding to each data port, will light orange when the physical connec-
tion is established (that is, when the unit is powered on and a cable is plugged into the port with
Amber: Solid
Fatal error
Table 7 - Leaf Status LED
LED Condition
Description
Содержание Switch-IB
Страница 2: ...Doc MLNX 15 4748 324 2 Mellanox Technologies...
Страница 103: ...104 Mellanox Technologies Figure 77 InfiniBand QSFP Connector Symbol...
Страница 104: ...105 Mellanox Technologies Figure 78 QSFP Connector Male and Female Views...
Страница 111: ...112 Mellanox Technologies 6 7 8 9 10 11...
Страница 112: ...113 Mellanox Technologies 12 13 14 15 16 17...
Страница 113: ...114 Mellanox Technologies 18 19 20 21 WEEE 22 H 4 Chinese 1...
Страница 114: ...115 Mellanox Technologies 2 3 4 5 6 7 8 r r 368...
Страница 115: ...116 Mellanox Technologies 9 10 InfiniBand 11 12 13 14 15 UL CSA 16 QILQL DQG 8 6 9 5 9 39 9...
Страница 116: ...117 Mellanox Technologies 17 18 19 20 WEEE 21 56 8 3 3 36 71 7...
Страница 127: ...128 Mellanox Technologies 3 4 5 6 7 8 9 45 C 113 F 8 3...
Страница 144: ...145 Mellanox Technologies 5 6 7 8 9 10 11 FP 368...
Страница 146: ...147 Mellanox Technologies 19 20 21 2 2 71 7...