Rev 1.2
Mellanox Technologies
29
2.7.1.2 Manual Host Configuration
To perform initial configuration of the system:
Step 1.
Connect a host PC to the Console RJ45 (
) port of the system using the supplied harness
cable (DB9 to RJ45). Make sure to connect to the Console RJ45 port and not to the (Ethernet)
MGT port.
Step 2.
Configure a serial terminal program (for example, HyperTerminal, minicom, or Tera Term) on
your host PC with the settings described in
. Once you perform that, you should get the
CLI prompt of the system.
Table 9 - Serial Terminal Program Configuration
Parameter
Setting
Baud Rate
115200
Data bits
8
Stop bits
1
Parity
None
Flow Control
None
Step 3.
Login as
admin
and use
admin
as password. On the first login, the MLNX-OS configuration
wizard will start.
Step 4.
To configure network attributes and other initial parameters to the system, follow the configu-
ration wizard as shown in
.
Table 10 - Configuration Wizard Session
Wizard Session Display
Comments
Mellanox configuration wizard
Do you want to use the wizard
for initial configuration? yes
You must perform this configuration the first time you operate the
system or after resetting the system. Type ‘y’ and then press
<Enter>.
Step 1: Hostname? [switch ]
If you wish to accept the default hostname, press <Enter>. Other-
wise, type a different hostname and press <Enter>.
Step 2: Use DHCP on mgmt0
interface? [no] yes
Perform this step to obtain an IP address for the system. (mgmt0 is
the management port of the system).
If you wish the DHCP server to assign the IP address, type ‘yes’
and press <Enter>.
If you type ‘no’ (no DHCP), then you will be asked whether you
wish to use the ‘zeroconf’ configuration or not.
If you enter ‘no’ (no Zeroconf), you must enter a
static
IP, and the
session will continue.
Step 3: Enable IPv6? [yes]
The management interface will be able to use IPv6 addresses.
Step 4: Enable IPv6 auto-config
(SLAAC) on mgmt0 interface?
[no]
This turns on auto-configuration of the IPv6 addresses. This is
unsuitable for DHCPv6.
Содержание SB7700
Страница 25: ...Rev 1 2 Mellanox Technologies 25 Figure 19 Locking Mechanism...
Страница 60: ...Rev 1 2 Mellanox Technologies 60 5 6 7 8 9 10...
Страница 61: ...Rev 1 2 Mellanox Technologies 61 11 12 13 14 15 16...
Страница 62: ...Rev 1 2 Mellanox Technologies 62 17 18 19 20 21 WEEE 22...
Страница 64: ...Rev 1 2 Mellanox Technologies 64 7 8 9 10 InfiniBand 11 12 13 PSU InfiniBand...
Страница 77: ...Rev 1 2 Mellanox Technologies 77 4 5 45 C 113 F 8 3 6 7 8 9 10 InfiniBand InfiniBand...
Страница 78: ...Rev 1 2 Mellanox Technologies 78 11 12 13 14 15 16 UL CSA UL CSA 3 16 AWG 1 5 6 4 5 125 13 HAR 3 1 0 300 250 10...