background image

  Mellanox 1036/6018/6015/6025/6036 SwitchX® and Metrox® Switch Systems Dismantling Guide 

Rev 1.1   

 

 

 

 

 

 

Mellanox Technologies Confidential 

 

OPN 

Description 

MSX6018F-1BRS 

SwitchX®-2 based 18-port QSFP FDR 1U managed InfiniBand switch 
system with a non-blocking switching capacity of 2Tb/s. 1PS, short depth, 
reverse airflow*, RoHS6 

MSX6018T-1SFS 

SwitchX®-2 based 18-port QSFP FDR10 1U managed InfiniBand switch 
system with a non-blocking switching capacity of 2Tb/s. 1PS, standard 
depth, forward airflow, RoHS6 

MSX6018T-1BRS 

SwitchX®-2 based 18-port QSFP FDR10 1U managed InfiniBand switch 
system with a non-blocking switching capacity of 2Tb/s. 1PS, short depth, 
reverse airflow, RoHS6 

MSX6015F-1SFS 

SwitchX®-2 based FDR InfiniBand Switch, 18 QSFP ports, 1 power 
supply ,Standard depth, Unmanaged with a non-blocking switching 
capacity of 2Tbps, PSU side to Connector airflow, Rail Kit and RoHS6 

MSX6015F-1BRS 

SwitchX®-2 based FDR InfiniBand Switch, 18 QSFP ports, 1 Power 
Supply, Short depth, Unmanaged with a non-blocking switching capacity 
of 2Tbps, Connector side to PSU side airflow, Rail Kit 

MSX6015T-1SFS 

SwitchX®-2 based FDR10 InfiniBand Switch, 18 QSFP ports, 1 Power 
Supply, Standard depth, Unmanaged with a non-blocking switching 
capacity of 2Tbps, PSU side to Connector side airflow, Rail Kit 

MSX6015T-1BRS 

SwitchX®-2 based FDR10 InfiniBand Switch, 18 QSFP ports, 1 Power 
Supply, Short depth, Unmanaged with a non-blocking switching capacity 
of 2Tbps, Connector side to PSU side airflow, Rail Kit 

1.2 

Policy Statement   

Mellanox Technologies recognizes the importance of developing connectivity solutions that 
not only enable our customers to optimize their data centers performance, but also protect the 
environment and ensure that future generations enjoy its bounties. Mellanox Technologies is 
committed, therefore, to meeting the requirements of the European Union’s WEEE (waste 
electrical and electronic equipment) directive. The directive mandates how the materials used 
in electrical and electronic equipment must be disposed of. 

Mellanox Technologies has worked closely with its suppliers to eliminate hazardous materials 
from its products. There are instances, however, where it has not proven possible to 
completely eliminate all hazardous materials. Consequently, all applicable products are 
labeled with a crossed out “wheelie” bin symbol, indicating that special care must be applied 
to their disposal and / or recycling.   

 

 

 

 

 

 

 

Figure 1 - Special Care Label

 

Содержание MetroDX MTX6000-2SFS

Страница 1: ...www mellanox com Mellanox Technologies Confidential Mellanox 1036 6018 6015 6025 6036 SwitchX and Metrox Switch Systems Dismantling Guide Rev 1 1 ...

Страница 2: ...S AS IS WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS THE CUSTOMER S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCTO S AND OR THE SYSTEM USING IT THEREFORE MELLANOX TECHNOLOGIES CANNOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PR...

Страница 3: ...Instructions 10 2 1 Switch Components 10 2 2 General Preparations 11 2 3 Power Supply Unit Extraction 11 2 4 Fan Unit Extraction 12 2 5 Cover Extraction 12 2 6 Battery Extraction Managed Switches Only 13 2 7 Front Panel Extraction 13 2 8 Harness Extraction 14 2 9 Secondary Boards Extraction 14 2 10 CPU and Main Board Extraction 15 ...

Страница 4: ...tch Components 10 Figure 4 Power Side of the Switch 11 Figure 5 Switch with 1 PSU 2 PSUs Removed 11 Figure 6 Extracting the Fan Unit 12 Figure 7 Remove Cover 12 Figure 8 Remove Battery 13 Figure 9 Front Panel 13 Figure 10 Harness Connections 14 Figure 11 Secondary Boards 14 Figure 12 Remove Heat Sink and Board 15 ...

Страница 5: ...Contents Rev 1 1 5 Mellanox Technologies Confidential List of Tables Table 1 Revision History 6 Table 2 Mellanox Switch OPNs 7 ...

Страница 6: ...Rev 1 1 Contents 6 Mellanox Technologies Confidential Revision History Table 1 Revision History Revision Date Description 1 1 January 2014 Added MetroX SX6018 systems 1 0 2011 Initial revision ...

Страница 7: ... RoHS6 MTX6240 2SFS MetroX 40km long haul 40G FRU system 2 long haul QSFP ports 2 Power Supplies Standard depth Managed PSU side to connector side airflow Rail Kit and RoHS6 MTX6280 2SFS MetroX 80km long haul 40G FRU system 2 long haul QSFP ports 2 Power Supplies Standard depth Managed PSU side to connector side airflow Rail Kit and RoHS6 MSX1036B 1BFR SwitchX based 36 port QSFP 40GigE 1U Ethernet...

Страница 8: ...witchX based FDR InfiniBand Switch 36 QSFP ports 1 Power Supply Standard depth Managed Subnet Manager for 648 nodes included PSU side to Connector side airflow Rail Kit and RoHS6 MSX6036F 1BRR SwitchX based FDR InfiniBand Switch 36 QSFP ports 1 Power Supply Short depth Managed Subnet Manager for 648 nodes included Connector side to PSU side airflow with rack rails MSX6036T 1BRR SwitchX based FDR 1...

Страница 9: ...niBand Switch 18 QSFP ports 1 Power Supply Standard depth Unmanaged with a non blocking switching capacity of 2Tbps PSU side to Connector side airflow Rail Kit MSX6015T 1BRS SwitchX 2 based FDR10 InfiniBand Switch 18 QSFP ports 1 Power Supply Short depth Unmanaged with a non blocking switching capacity of 2Tbps Connector side to PSU side airflow Rail Kit 1 2 Policy Statement Mellanox Technologies ...

Страница 10: ... NOTE The figures in this guide are based on SX6018 SX6025 SX6036 SX1036 SwitchX switch systems but apply to MetroX switch systems as well despite their different front panel 2 1 Switch Components Switch systems are comprised of 1 Main board 2 CPU board with battery Not found on unmanaged switches 3 Fan unit 4 Harnesses 5 Power Supply Unit PSU 6 Cover 7 Secondary boards Figure 2 Switch Main Compon...

Страница 11: ... the following pages provide visual guidance explaining how to remove the modules from the mechanical base 2 3 Power Supply Unit Extraction Figure 4 Power Side of the Switch To extract the PSU 1 Remove the power cord from the power supply unit 2 Grasping the handle with one hand push the latch release with your thumb while pulling the handle outward 3 Remove the PSU 4 Repeat the procedure for the ...

Страница 12: ...while pulling the fan module out of the switch Figure 6 Extracting the Fan Unit These two latches must be pushed towards each other at the same time while the module is pulled out 2 5 Cover Extraction Unscrew all of the screws from the top and sides of the cover Slide the cover to the power side and remove the cover Figure 7 Remove Cover I2C OK Mellanox OK ...

Страница 13: ...Mellanox systems there is a CPU board and or Management board with a COIN TYPE LITHIUM BATTERY CR1620 3V 75MA Remove the battery before removing the board Figure 8 Remove Battery 2 7 Front Panel Extraction Unscrew the 6 Philips screws attaching the panel itself to the switch and the additional two screws connecting the LED board Disconnect the LED board connector Figure 9 Front Panel Battery ...

Страница 14: ...ness Extraction Disconnect the harness connections and remove harnesses from the base Figure 10 Harness Connections 2 9 Secondary Boards Extraction Unscrew the Philips screws and remove screws and spacers to extract the secondary boards Figure 11 Secondary Boards Secondary Boards ...

Страница 15: ...llanox Technologies Confidential 2 10 CPU and Main Board Extraction Unscrew the Heat sink screws to extract the Heat sink Unscrew the Philips screws and remove spacers to extract the CPU Board Unscrew the Philips screws and remove spacers to extract the Main board Figure 12 Remove Heat Sink and Board ...

Отзывы: