Mellanox Technologies
7.11 Airflow Specifications
Table 18 - Airflow Specifications
7.12 Adapter Card LED Operations
There is one bi-color I/O LED per port to indicate physical and logical link status. See
.
Table 19 - Physical and Logical Link Indications
Air Flow (LFM)
a
a. Cells marked with (–) are not applicable
Air Flow Direction
Heat Sink to Port
Port to Heat Sink
Cable Type
Passive
Active
1.5W
Active
3.5W
Passive
Active
1.5W
Active
3.5W
MCX413A-BCAT
400
450
–
400
400
–
MCX414A-BCAT
400
450
–
400
400
–
MCX416A-BCAT
400
500
–
400
400
–
MCX413A-GCAT
400
400
–
400
400
–
MCX414A-GCAT
400
450
700
400
400
600
MCX416A-GCAT
400
500
–
400
400
–
MCX415A-CCAT
400
–
700
400
–
600
MCX416A-CCAT
400
–
850
400
–
600
LED Color and State
Description
Off
A link has not been established
Blinking Amber
a
a. 1 Hz Blinking Amber occurs due to running a beacon command for locating the adapter card.
6Hz Blinking Amber indicates a problem with the link
Solid Green
Indicates a valid link with no active traffic
Blinking Green
Indicates a valid link with active traffic