![Mellanox Technologies ConnectX-3 Pro Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/mellanox-technologies/connectx-3-pro/connectx-3-pro_user-manual_1768342019.webp)
ConnectX®-3 Pro Ethernet Single and Dual SFP+ Port Adapter Card User Manual
Rev 1.5
Mellanox Technologies
19
Figure 6: Module With Locking Mechanism Closed
Figure 7: Module With Locking Mechanism Open
3. Insert the module into the adapter card module cage.
4. Close the locking Mechanism.
To remove the module from the cage:
1. Unlock the locking mechanism by opening the handle.
2. Pull the module out of the cage.
3.6.2
Cable Installation
1. All cables can be inserted or removed with the unit powered on.
2. To insert a cable, press the connector into the port receptacle until the connector is firmly
seated.
3. After inserting a cable into a port, the Green LED indicator will light when the physical con-
nection is established (that is, when the unit is powered on and a cable is plugged into the port
with the other end of the connector plugged into a functioning port). See
“Adapter Led Operations,” on page 50
4. After plugging in a cable, lock the connector using the latching mechanism particular to the
cable vendor. When a logical connection is made the Yellow LED will light. When data is
being transferred the yellow led will blink. See
Section 7.4, “Adapter Led Operations,” on
.
5. Care should be taken as not to impede the air exhaust flow through the ventilation holes. Use
cable lengths which allow for routing horizontally around to the side of the chassis before
bending upward or downward in the rack.
6. To remove a cable, disengage the locks and slowly pull the connector away from the port
receptacle. Both LED indicators will turn off when the cable is unseated.
When installing cables make sure that the latches engage.
Always install and remove cables by pushing or pulling the cable and connector in a
straight line with the card.