Mellanox Technologies 0NHYP5 Скачать руководство пользователя страница 35

ConnectX-4 100Gb/s Ethernet Dual Port Adapter Card User Manual for Dell PowerEdge

Rev 1.2

Mellanox Technologies

35

4.1.8.2 Removing Signature from Kernel Modules

The signature can be removed from a signed kernel module using the 'strip' utility which is pro-
vided by the 'binutils' package.

The strip utility will change the given file without saving a backup. The operation can be undo 
only by resigning the kernel module. Hence, we recommend backing up a copy prior to removing 
the signature.

To remove the signature from the MLNX_OFED kernel modules:

 Step 1.

Remove the signature.

After the signature has been removed, a massage as the below will no longer be presented 
upon module loading:

However, please note that a similar message as the following will still be presented:

This message is presented once, only for each boot for the first module that either has no 
signature or whose key is not in the kernel key ring. So it's much easier to miss this mes-
sage. You won't see it on repeated tests where you unload and reload a kernel module until 
you reboot. There is no way to eliminate this message.

 Step 2.

Update the initramfs on RHEL systems with the stripped modules.

4.1.9

Performance Tuning

Depending on the application of the user's system, it may be necessary to modify the default con-
figuration of network adapters based on the ConnectX® adapters In case tuning is required, 
please refer to the 

Performance Tuning Guide for Mellanox Network Adapters

# strip -g my_module.ko

# rpm -qa | grep -E "kernel-ib|mlnx-ofa_kernel|iser|srp|knem" | xargs rpm -ql | grep 
"\.ko$" | xargs strip -g

"Request for unknown module key 'Mellanox Technologies signing key: 
61feb074fc7292f958419386ffdd9d5ca999e403' err -11"

"my_module: module verification failed: signature and/or required key missing - taint

-

ing kernel"

mkinitrd /boot/initramfs-$(uname -r).img $(uname -r) --force

Содержание 0NHYP5

Страница 1: ...www mellanox com ConnectX 4 100Gb s Ethernet Dual QSFP28 Adapter Card User Manual for Dell PowerEdge P N 0NHYP5 0XR0K2 Rev 1 2...

Страница 2: ...OR TEST SUITE PRODUCT PRODUCT S AND ITS RELATED DOCUMENTATION ARE PROVIDED BY MELLANOX TECHNOLOGIES AS IS WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLI...

Страница 3: ...I Express Interface 15 2 3 LED Interface 15 Chapter 3 Hardware Installation 16 3 1 System Requirements 16 3 1 1 Hardware 16 3 2 Operating Systems Distributions 16 3 2 1 Software Stacks 16 3 3 Safety P...

Страница 4: ...ng the Device Online 33 4 1 7 2 Updating the Device Manually 33 4 1 7 3 Updating the Device Firmware Automatically upon System Boot 33 4 1 8 UEFI Secure Boot 34 4 1 8 1 Enrolling Mellanox s x 509 Publ...

Страница 5: ...wing and Dimensions 55 7 5 Bracket Mechanical Drawings 56 Appendix A Interface Connectors Pinout 57 A 1 QSFP28 Connector Pinout 57 A 2 PCI Express x16 Edge Connector Pinout 58 Appendix B Finding the M...

Страница 6: ...ion History Table 8 Table 2 Documents List 9 Table 3 Dual port Ethernet Adapter Cards 12 Table 4 Features 13 Table 5 Hardware and Software Requirements 23 Table 6 Hardware and Software Requirements 36...

Страница 7: ...Installation Results Example 43 Figure 3 Mechanical Drawing of the Single port x16 Adapter Card 55 Figure 4 Mechanical Drawing of the Dual port x16 Adapter Card 55 Figure 5 Dual port Low Profile Brack...

Страница 8: ...pdated Linux Driver on page 23 Updated Windows Driver on page 36 Updated VMware Driver on page 47 Updated 0NHYP5 0XR0K2 Specifications on page 53 Updated Airflow Specifications on page 54 Updated Adap...

Страница 9: ...mlxup Firmware Utility Mellanox OFED for Linux User Manual Document no 2877 User Manual describing OFED features performance InfiniBand diagnostic tools content and configuration See http www mella no...

Страница 10: ...who purchased Mellanox products through a Mellanox approved reseller should first seek assistance through their reseller Firmware Updates The Mellanox support downloader contains software firmware and...

Страница 11: ...cuit device These adapters connectivity provide the highest performing and most flexible interconnect solution for PCI Express Gen3 servers used in Enterprise Data Centers High Performance Computing a...

Страница 12: ...ed Each adapter comes with two bracket heights short and tall Table 3 Dual port Ethernet Adapter Cards Ordering Part Number OPN 0XR0K2 short bracket 0NHYP5 tall bracket Data Transmission Rate Ethernet...

Страница 13: ...verlay networks that carry traffic from individual virtual machines over logical tunnels in encapsulated formats such as NVGRE and VXLAN While this solves network scalability issues it hides the TCP p...

Страница 14: ...r latency and SLA Hardware based I O Virtualization ConnectX 4 provides dedicated adapter resources and guaranteed isolation and protection for virtual machines within the server Storage Acceleration...

Страница 15: ...eatures on page 13 Ethernet traffic is transmitted through the cards QSFP28 connectors 2 2 PCI Express Interface The ConnectX 4 adapter card supports PCI Express 3 0 1 1 and 2 0 compatible through an...

Страница 16: ...stated above 2 Shut down your system if active 3 After shutting down the system turn off power and unplug the cord 4 Remove the card from its package Please note that the card must be placed on an ant...

Страница 17: ...lbf in torque on the screws 3 6 Card Installation Instructions 1 Before installing the card make sure that the system is off and the power cord is not con nected to the server Please follow proper el...

Страница 18: ...ligned with the slot opening and the adapter faceplate is visible against the system chassis 6 Secure the adapter with the adapter clips or screws 7 Close the system case 3 7 Cables and Modules To obt...

Страница 19: ...ons on page 54 4 After plugging in a cable lock the connector using the latching mechanism particular to the cable vendor When data is being transferred the Green LED will blink See Section 7 3 Adapte...

Страница 20: ...nisms on the bracket clips or screws 4 Holding the adapter card from its center gently pull the adapter card from the PCI Express slot 5 When the port connectors reach the top of the chassis window ge...

Страница 21: ...Value display box check the fields VEN and DEV fields are separated by In the display example above notice the sub string PCI VEN_15B3 DEV_1003 VEN is equal to 0x15B3 this is the Vendor ID of Mellanox...

Страница 22: ...onnectX 4 100Gb s Ethernet Dual Port Adapter Card User Manual for Dell PowerEdge Rev 1 2 Mellanox Technologies 22 lspci grep i Mellanox Network controller Mellanox Technologies MT4115 Family ConnectX...

Страница 23: ...arch iso You can download it from http www mellanox com Products Soft ware Ethernet Drivers Table 5 Hardware and Software Requirements Requirements Description Platforms A server platform with an ada...

Страница 24: ...nodes and then copy it to a shared file system such as NFS To install on all the cluster nodes use cluster aware tools such as pdsh If your kernel version does not match with any of the offered pre b...

Страница 25: ...machine as root Step 2 Mount the ISO image on your machine Step 3 Run the installation script MLNX_OFED_LINUX x x x rhel6 3 x86_64 mlnx_add_kernel_support sh m tmp MLNX_OFED_ LINUX x x x rhel6 3 x86_6...

Страница 26: ...installation such as prefix kernel version and installation parameters can be retrieved by running the command etc infiniband info Most of the Mellanox OFED components can be configured or reconfigure...

Страница 27: ...the opt directory openshmem bupc fca and ibutils The kernel modules are installed under lib modules uname r updates on SLES and Fedora Distributions lib modules uname r extra mlnx ofa_kernel on RHEL a...

Страница 28: ...allation machine as root Step 2 Mount the ISO image on your machine and copy its content to a shared location in your net work You can download it from http www mellanox com Products Software Ether ne...

Страница 29: ...nox 100 1 354 K s in 0s 2014 04 20 13 52 30 247 MB s RPM GPG KEY Mellanox saved 1354 1354 sudo rpm import RPM GPG KEY Mellanox warning rpmts_HdrFromFdno Header V3 DSA SHA1 Signature key ID 6224c050 NO...

Страница 30: ...a vpi installer package with KMP support mlnx ofed all Installs all available packages in MLNX_OFED mlnx ofed basic Installs basic packages required for running Mellanox cards mlnx ofed guest Installs...

Страница 31: ...e of installation is applicable to Debian and Ubuntu Operating Systems 4 1 6 1 Setting up MLNX_OFED apt get Repository Step 1 Log into the installation machine as root Step 2 Extract the MLNX_OFED pac...

Страница 32: ...4g 09FCC269 2013 08 11 sudo apt get update apt cache search mlnx ofed mlnx ofed vma eth MLNX_OFED vma eth installer package with DKMS support mlnx ofed hpc MLNX_OFED hpc installer package with DKMS su...

Страница 33: ...the firmware Step 4 Reboot your machine after the firmware burning is completed 4 1 7 3 Updating the Device Firmware Automatically upon System Boot As of MLNX_OFED v3 1 x x x firmware can be automati...

Страница 34: ...onto the system key ring by the kernel Follow these steps below to add the Mellanox s x 509 public key to your system Step 1 Download the x 509 public key Step 2 Add the public key to the MOK list us...

Страница 35: ...each boot for the first module that either has no signature or whose key is not in the kernel key ring So it s much easier to miss this mes sage You won t see it on repeated tests where you unload an...

Страница 36: ...n 2 Open a CMD console Click Task Manager File Run new task and enter CMD 3 Enter the following command On an x64 64 bit machine the output will be AMD64 Step 2 Go to the Mellanox WinOF 2 web page at...

Страница 37: ...equires no user intervention 4 2 3 1 Attended Installation The following is an example of an installation session Step 1 Double click the exe and follow the GUI instructions to install MLNX_WinOF2 Ste...

Страница 38: ...Gb s Ethernet Dual Port Adapter Card User Manual for Dell PowerEdge Rev 1 2 Mellanox Technologies 38 Step 5 Read then accept the license agreement and click Next Step 6 Select the target folder for th...

Страница 39: ...following cases If the user has an OEM card In this case the firmware will not be displayed If the user has a standard Mellanox card with an older firmware version the firmware will be updated accord...

Страница 40: ...ver and installed automatically Performances tools install the performance tools that are used to measure performance in user envi ronment Analyze tools install the tools that can be used either to di...

Страница 41: ...t Adapter Card User Manual for Dell PowerEdge Rev 1 2 Mellanox Technologies 41 b Click Install to start the installation Step 9 In case firmware upgrade option was checked in Step 7 you will be notifi...

Страница 42: ...s option Step 4 Optional if you want to control whether to install ND provider or not1 Step 5 Optional If you do not wish to upgrade your firmware version2 If no reboot options are specified the insta...

Страница 43: ...F2 Drivers OS To see the Mellanox network adapters display the Device Manager and pull down the Net work adapters menu Figure 2 Installation Results Example 4 2 5 Extracting Files Without Running Inst...

Страница 44: ...ual for Dell PowerEdge Rev 1 2 Mellanox Technologies 44 To extract only the driver files Step 3 Click Next to create a server image Step 4 Click Change and specify the location in which the files are...

Страница 45: ...Click Install to extract this folder or click Change to install to a different folder Step 6 To complete the extraction click Finish 4 2 6 Uninstalling Mellanox WinOF 2 Driver 4 2 6 1 Attended Uninst...

Страница 46: ...ill be automatically updated as part of the WinOF 2 package installation For information on how to upgrade firmware manually please refer to MFT User Manual www mellanox com Products Ethernet Drivers...

Страница 47: ...r was installed successfully Table 7 Hardware and Software Requirements Requirements Description Platforms A server platform with an adapter card based on one of the following Mellanox Technologies HC...

Страница 48: ...0 from the Mellanox Firmware Tools MFT site ESX 5 5 File mft 4 3 0 25 10EM 550 0 0 1391871 x86_64 vib MD5SUM 62f953b77f4ea49c420ff4e1ce8b925b ESX 6 0 File mft 4 3 0 25 10EM 600 0 0 2768847 x86_64 vib...

Страница 49: ...ard User Manual for Dell PowerEdge Rev 1 2 Mellanox Technologies 49 2 Install the image according to the steps described in the MFT User Manual The following procedure requires custom boot image downl...

Страница 50: ...n are available from http www mellanox com Products Software Firmware Tools 5 1 Firmware Update Example server1 mlxup Querying Mellanox devices firmware Device Type ConnectX4 Part Number 0XR0K2 Descri...

Страница 51: ...adapter in its slot or a different slot if necessary Try using another cable Reinstall the drivers for the network driver files may be damaged or deleted Reboot the server Adapters stopped working af...

Страница 52: ...ibdev2netdev Card Detection lspci grep i Mellanox Mellanox Firmware Tool MFT Download and install MFT http www mellanox com content pages php pg management_tools menu_section 34 Refer to the User Manu...

Страница 53: ...G R EC 10GBASE SR 10GBASE LR 10GBASE ER 10GBASE CX4 SGMII 1000BASE X Data Rate 10 25 40 50 100 Gb s Ethernet PCI Express Gen3 SERDES 8 0GT s 16 lanes 2 0 and 1 1 compatible Power and Environmental Vol...

Страница 54: ...vide additional cooling For information on how to adjust the fan speed on Dell PowerEdge servers please refer to the Dell iDRAC User s Guide for that server Please contact your Dell account team for g...

Страница 55: ...llanox Technologies 55 7 4 Board Mechanical Drawing and Dimensions Figure 3 Mechanical Drawing of the Single port x16 Adapter Card Figure 4 Mechanical Drawing of the Dual port x16 Adapter Card All dim...

Страница 56: ...2 Mellanox Technologies 56 7 5 Bracket Mechanical Drawings Figure 5 Dual port Low Profile Bracket Figure 6 Dual port Full Height Bracket Port 1 Link and Activity Bi color LED Port 2 Link and Activity...

Страница 57: ...Connector Pinout Figure 7 Connector and Cage Views Table 10 Connector Pin Number and Name to Signal Name Map Connector Pin Number Connector Pin Name Port A Signal Name 1 GND GND 2 TXN_2 Tx2n 3 TXP_2 T...

Страница 58: ...rding to the PCI Express 3 0 specification 16 GND GND 17 RXP_1 Rx1p 18 RXN_1 Rx1n 19 GND GND 20 GND GND 21 RXN_2 Rx2n 22 RXP_2 Rx2p 23 GND GND 24 RXN_4 Rx4n 25 RXP_4 Rx4p 26 GND GND 27 ModPrsl_Port0 M...

Страница 59: ...ConnectX 4 100Gb s Ethernet Dual Port Adapter Card User Manual for Dell PowerEdge Rev 1 2 Mellanox Technologies 59 Figure 8 PCIe x16 Connector Pinout...

Страница 60: ...C and Serial Number on the Adapter Card Each Mellanox adapter card has a different identifier printed on the label serial number and the card MAC for the Ethernet protocol Figure 9 0NHYP5 0XR0K2 Board...

Страница 61: ...ConnectX 4 100Gb s Ethernet Dual Port Adapter Card User Manual for Dell PowerEdge Rev 1 2 Mellanox Technologies 61...

Страница 62: ...proper air flow allow at least 8cm 3 inches of clearance around the ven tilation openings During periods of lightning activity do not work on the equipment or connect or dis connect cables Some coppe...

Страница 63: ...Dual Port Adapter Card User Manual for Dell PowerEdge Rev 1 2 Mellanox Technologies 63 CLASS 1 LASER PRODUCT and reference to the most recent laser standards IEC 60 825 1 1993 A1 1997 A2 2001 and EN...

Страница 64: ...air de 200LFM cette temp rature ambiante maximale est n cessaire En outre pour garantir un bon coulement de l air laissez au moins 8 cm 3 pouces d espace libre autour des ouver tures de ventilation P...

Страница 65: ...65 8 Exposition au rayonnement grave Mise en garde l utilisation de commandes ou de r glages ou l ex cution de proc dures autres que ce qui est sp cifi dans les pr sentes peut engendrer une expositio...

Страница 66: ...peratur erforderlich Au erdem sollten mindestens 8 cm 3 in Freiraum um die Bel ftungs ffnungen sein um einen einwandfreien Luftstrom zu gew hrleisten Arbeiten Sie w hrend eines Gewitters und Blitzschl...

Страница 67: ...2 Mellanox Technologies 67 8 Strahlenkontak Achtung Nutzung von Steuerungen oder Einstellungen oder Ausf hrung von Prozeduren die hier nicht spezifiziert sind kann zu gef hrlichem Strahlenkon takt f h...

Страница 68: ...ire adecuada se debe dejar como m nimo un espacio de 8 cm 3 pulgadas alrededor de las aberturas de ventilaci n No utilizar el equipo ni conectar o desconectar cables durante per odos de actividad de r...

Страница 69: ...onnectX 4 100Gb s Ethernet Dual Port Adapter Card User Manual for Dell PowerEdge Rev 1 2 Mellanox Technologies 69 PRODUCTO L SER DE CLASE 1 y referencia a las normas de l ser m s recientes IEC 60825 1...

Отзывы: