GDB-5K30
Instructions Manual
10.Specifications
10-1.General Specifications
DC+24V
*1 (Ripple voltage P-P 2.0V or less)
●
Rated input current :
〔DRIVE I.SEL ⇒ No.F set up〕
at DRIVE
DC+24V: 1.5A
*2
●
Rated input current :
〔HOLD I.SEL ⇒ Approx. 40% set up〕
at HOLD
DC+24V: 0.3A
●DRIVE CURRENT
0.30A/phase~0.75A/phase
●HOLD CURRENT
Approx. 40% of DRIVE CURRENT (factory-set)
●Drive pulse input
(CW, CCW)
Photo-coupler input
●Motor excitation stop input
(M.F)
Photo-coupler input
●Step angle switch input
(C.S)
Photo-coupler input
●Phase signal output
(P.O)
O/C output
●Overheat alarm output
(O.H.A)
O/C output
●MOTOR selection
(MOTOR SEL)
●STEP TABLE selection
(S.T SEL)
●Step angle selection
(STEP SEL)
●HOLD CURRENT selection
(HOLD I.SEL)
●DRIVE CURRENT selection
(DRIVE I.SEL)
●PULSE INPUT TYPE selection
(SPI SEL)
●HOLD switching time selection
(DHT SEL)
●ROTATE MODE SELECT switch
(RM SEL)
●EXTEND FUNCTION SELECT switch
(OP SEL)
Indoor (Exposure to direct sun is not allowed.)
Without any explosive, corrosive or inflammable gas, oil mist,
or dust.
*1
Input voltage range is DC+24V±10%.
*2
Use a power supply that provides sufficient input current.
Insulation resistance
Exterior Dimensions
Weight
Operating Ambient
Temperature
Supply Power
Input Signal
Output Signal
Altitude
Motor output
current
Functions of
Operating Sections
Operating Ambient
Humidity
Storing Temperature
Storing Humidity
Atmosphere
Withstanding
Vibration
W
75 ×
H
65 ×
D
29 (mm)
0.1 kg
DC connector - signal connector - Frame
(Each other)
DC500V 100MΩ or more
0℃ ~ +50℃
(No freezing allowed.)
80%RH or less
(No condensation allowed.)
-10℃ ~ +55℃
(No freezing allowed.)
80%RH or less
(No condensation allowed.)
Up to 1000m above sea level
No abnormality should be found after a vibration test
at 10~55Hz, 0.15mm P-P
-35-