GD-5610
Instructions Manual
4-7.Setting PULSE INPUT TYPE SELECT switch
Erroneous setting may cause breakage of
the machine or injury due to unexpected
rotation of motor.
Ensure correct setting.
2-pulse input method / 1-pulse input method are
set up by the SPI SEL switch.
(1) Set the SPI SEL switch.
● When the motor is operated with two pulse signal inputs of CW and CCW,
set the SPI SEL switch to [OFF].
● When the motor is operated with the pulse signal and direction signal
input, set the SPI SEL switch to [ON].
● In the case that 1-pulse input method is selected, the CCW terminal becomes
direction signal input designating the direction of the motor rotation.
Drive pulse set to the CW terminal(CW+,CW-).
● The input timing is same with 2-pulse input method and 1-pulse input method .
As for input timing, refer to "10-3. (2)Drive pulse input(CW, CCW)"
(Factory Setting)
SPI SEL
Input type
1PULSE (1P)
2PULSE (2P)
ON
OFF
CCW terminal(CCW+,CCW-)
direction set
Photo-coupler OFF: CCW direction
Photo-coupler ON : CW direction
CAUTION