ADB-5F41EL
Instructions Manual
6-4.Connecting Encoder I/O Connecter(J4)
The following items are required:
●Housing for J4 (51103-0800:Molex)
One unit
●Contact for J4 (50351-8100:Molex)
9 contacts
●Manually operated crimping tool
One unit
for AWG28-22(57295-5000:Molex)
(1) Crimp the contact to the cable used for wiring.
(2) Insert the contact into the housing.
Make sure that the housing No. and the connector No. on the main frame are
matched before inserting the contacts.
(3) Connect the housings to the connectors on the main frame.
●The contacts for J4 are 9 pieces.
●When inserting, keep pushing J4 housing into the connectors until it is locked.
Also, check if the contacts are not displaced from the housing.
●In wiring, isolate the J4 signal lines from equipment that may be
さい。
a source of noise, the power line and the motor line.
●Use a cable of 5m or less for the encoder cable .
(Surface on which the contacts are inserted)
Housing for J4
〈Crimping〉
〈Connection〉 〈Insertion〉〈Wiring〉
ADB-5F41EL
Contact
Encoder
J4
Z
B
7
Housing
for J4
SHIELD
GND
+5V
8
Encoder A phase
signal
SHIELD
Encoder Z phase
signal
Encoder B phase
signal
SHIELD
GND
+5V
Z
Z
B
B
A
A
9
Encoder power
supply
8
7
9
A
6
5
4
3
B
2
5
A
2
6
1
3
1
4
Z
9
8
7
6
5
4
3
2
1
(0.15mm
2
or more,
5m Max.)
-22-