4-5.Setting PULSE INPUT TYPE SELECT switch
Erroneous setting may cause breakage of
the machine or injury due to unexpected
rotation of motor.
Ensure correct setting.
2-pulse input method/1-pulse input method are
set up by the PULSE INPUT TYPE SELECT switch.
Set this switch with power OFF.
The switch is factory-set to 2-pulse input method[2P].
(1) Turn power [OFF].
(2) Set the SPI SEL [2P/1P] switch.
● When the motor is operated with two pulse signal inputs of CW and CCW,
switch the SPI SEL to [OFF(2P)].
● When the motor is operated with the pulse signal and direction signal
input, switch SPI SEL to [ON(1P)].
● In the case that 1-pulse input method is selected, the CCW terminal becomes
direction signal input designating the direction of the motor rotation.
Drive pulse set to the CW terminal(CW+,CW-).
● The input timing is same with 2-pulse input method and 1-pulse input method .
As for input timing, please refer to "10-2. (2)Drive pulse input(CW, CCW)"
SPI SEL
ON
OFF
Input type
1PULSE (1P)
2PULSE (2P)
CCW terminal(CCW+,CCW-)
direction set
Photo-coupler OFF: CCW direction
Photo-coupler ON : CW direction
I
-17-
Содержание ADB-5431
Страница 30: ...Instructions Manual 10 2 I O Signal 1 Example Circuit Connection 30 ...
Страница 35: ...Instructions Manual 10 4 Dimensions Unit mm 35 ...
Страница 38: ...Instructions Manual 38 ...
Страница 39: ...Instructions Manual 39 ...
Страница 40: ...Instructions Manual 40 ...
Страница 41: ...Instructions Manual 41 ...