12
Because the calculation of the plans is based on greater/less compa-
rations of the switching times it is necessary to sort the switching
programs of one relay in a chronological order, but not all successive
switching programs have to be programmed.
ATTENTION
1. Example: correct programming
PRG: 01 REL.:1
EIN: 08:00:00
AUS: 08:00:03
PRG: 02 REL.:1
EIN: 08:40:00
AUS: 09:45:00
PRG: 03 REL.:1
EIN: — :— :—
AUS: —:— :—
.
.
PRG: 09 REL.:1
EIN: — :— :—
AUS: —:— :—
PRG: 11 REL.:1
EIN: 23:12:00
AUS: 23:54:00
2. Example: correct programming
PRG: 01 REL.:1
EIN: 08:00:00
AUS: 08:00:03
PRG: 02 REL.:3
EIN: 06:40:00
AUS: 20:45:00
PRG: 03 REL.:1
EIN: 12:30:00
AUS: 12:30:03
.
.
PRG: 09 REL.:2
EIN: 11:55:00
AUS: 11:57:00
PRG: 11 REL.:4
EIN: 23:12:00
AUS: 23:54:00
PRG: 12 REL.:2
EIN: 12:00:00
AUS: —:—:—
3. Example: incorrect programming
PRG: 01 REL.:1
EIN: 08:00:00
AUS: 08:00:03
PRG: 02 REL.:3
EIN: 06:40:00
AUS: 20:45:00
PRG: 03 REL.:1
EIN: 17:30:00
AUS: 18:00:00
.
.
PRG: 09 REL.:2
EIN: 11:55:00
AUS: —:—:—
PRG: 11 REL.:4
EIN: 23:12:00
AUS: 23:54:00
PRG: 12 REL.:1
EIN: 09:30:00
AUS: 09:30:03
In the third example the execution of the program 03 should switch on the relay
no. 1 at 17:30:00. However, the following program no. 12 causes the relay to keep
switched off because the actual time is past the switch-off time (09:30:03). The
program no. 03 is never executed.