14

Photocoupler input

Pulse width modulated (DC Level Shift) codes are insulated by an onboard photo-
coupler. The connection scheme is shown below:

The internal series resistance allows direct connection of input signals with a

maximum high level of +12 V (TTL or RS-422 for example). If signals with a higher
amplitude are used, an additional external series resistance must be applied for not
exceeding the limit of the forward current of the input diode (50 mA). The forward
current should not be limited to a value of less than 10 mA to ensure save switching
of the photocoupler.

Configuration of TCR510PCI

The selection of the IRIG code, configuration of the serial interface and a possible
offset of the received IRIG time to UTC must be set up by the monitor software via
the PCI bus. In contrast to AFNOR NFS 87-500 the IRIG telegram containes only the
day of year (1...366) instead of a complete date. To ensure correct function of
TCR510PCI, the date stored in the realtime clock of the board must be set when using
IRIG codes therefore. This setting can be done by a terminal software also.

If the time zone of the received IRIG code is not UTC, the local
offset to UTC must be configured to ensure correct function of the
driver software. If the local time zone is MEZ for example, the
board must be set to a local offset of ‘+60min’ (MEZ = UTC + 1 h).

The serial interface COM0 can be configured to send a time telegram with reference
to UTC or to the received local IRIG time.

Содержание TCR510PCI

Страница 1: ...TCR510PCI Technical Information Operating Instruction...

Страница 2: ...Impressum Meinberg Funkuhren GmbH Co KG Auf der Landwehr 22 D 31812 Bad Pyrmont Telefon 49 0 52 81 9309 0 Telefax 49 0 52 81 9309 30 Internet http www meinberg de Email info meinberg de March 08 2006...

Страница 3: ...nous serial port 10 Connectors and LEDs in the bracket 10 Pin assignments of the D Sub connector 11 Putting into operation 12 Installing the TCR510PCI in your Computer 12 Power supply 12 Input signals...

Страница 4: ...4 Diskette with driver software...

Страница 5: ...variant of the IRIG B format Within this code the complete date is transmitted instead of the Control Functions of the IRIG telegram Description of IRIG Codes The specification of individual IRIG time...

Страница 6: ...6 IRIG Standard format...

Страница 7: ...7 AFNOR Standard format...

Страница 8: ...otocoupler Two DIP switches must be set to the ON position for making this connection The board TCR510PCI provides a configurable serial interface RS 232 a pulse per second PPS with TTL or RS 232 leve...

Страница 9: ...with this offset Meinberg driver software is able to set the system time of the computer correctly The serial interface COM0 can send the Standard Meinberg Timestring with UTC or local IRIG time IRIG...

Страница 10: ...serial interface COM0 is used for a potential firmware update Connectors and LEDs in the bracket The bracket of the board includes the BNC connector for the amplitude modulated time co des three LEDs...

Страница 11: ...e are connected to the D Sub plug directly If another signal shall be connected to a pin of the plug a DIP switch must be set to the ON position Whenever an additional signal is connected to the rear...

Страница 12: ...efully The computer s case should be closed again before restarting the computer Power supply All power supplies needed by TCR510PCI are delivered by the PCI bus Input signals Amplitude modulated IRIG...

Страница 13: ...e requirements of several systems Meinberg IRIG generators have an output impedance of 50 to build a matched transmission system when using a coaxial cable If such a generator is used to synchroni ze...

Страница 14: ...e configuration of the serial interface and a possible offset of the received IRIG time to UTC must be set up by the monitor software via the PCI bus In contrast to AFNOR NFS 87 500 the IRIG telegram...

Страница 15: ...t depend on the contents of the flash memory so if the update procedure is interrupted it can easily be repeated The contents of the program memory will not be modified until the loader program has se...

Страница 16: ...RED ACCURACY OF TIME CODE SOURCE 100ppm HOLDOVER MODE automatic switching to crystal time base accuracy approximately 1E 6 if decoder has been synchronous for more than 1h BACKUP BATTERY if the power...

Страница 17: ...framing 7E2 8N1 8N2 8E1 mode of operation string per second string per minute string on request time telegram Meinberg Standard Telegram SYSTEM BUS INTERFACE 32 Bit 33 MHz or 66 MHz PCI Bus compatibl...

Страница 18: ...current date dd day of month 01 31 mm month 01 12 yy year of the century 00 99 w the day of the week 1 7 1 Monday hh mm ss the current time hh hours 00 23 mm minutes 00 59 ss seconds 00 59 or 60 whil...