background image

1 Imprint

1 Imprint

Meinberg Funkuhren GmbH & Co. KG

Lange Wand 9, 31812 Bad Pyrmont / Germany

Phone:

+ 49 (0) 52 81 / 93 09 - 0

Fax:

+ 49 (0) 52 81 / 93 09 - 230

Internet: https://www.meinbergglobal.com
Mail:

[email protected]

Date:

06.05.2021

TCR180PEX-EL

Date: 6th May 2021

1

Содержание TCR180PEX-EL

Страница 1: ...MANUAL TCR180PEX EL EL FO In 6th May 2021 Meinberg Funkuhren GmbH Co KG...

Страница 2: ......

Страница 3: ...ut 16 6 2 Signals of the D SUB9 Inferface 16 6 2 1 Optocoupler input 17 6 2 2 Pulse outputs 17 6 2 3 Asynchronous serial port 17 6 2 4 Time capture inputs 18 7 Before you start 19 7 1 Scope of Deliver...

Страница 4: ...ing 38 11 3 6 Format of the SPA Time String 39 11 3 7 Format of the RACAL standard Time String 40 11 3 8 Format of the ION Time String 41 11 4 PCI Express PCIe 42 11 5 Content of the USB stick 43 12 R...

Страница 5: ...berg Funkuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 06 05 2021 TCR180PEX...

Страница 6: ...the respective management program The TCR180PEX EL is used for synchronization of directly connected systems and can be equipped with a wide range of signal outputs for various applications Possible o...

Страница 7: ...th the following signal words you may only continue if you have understood and fulfilled all requirements In this documentation dangers and indications are classified and illustrated as follows DANGER...

Страница 8: ...ischen Schlages Caution risk of electric shock IEC 60417 5041 Vorsicht hei e Oberfl che Caution hot surface IEC 60417 6056 Vorsicht Gef hrlich sich bewegende Teile Caution moving fan blades IEC 60417...

Страница 9: ...it This device may only be used for the purpose described in this manual In particular the given limits of the device must be observed The safety of the installation in which the unit is integrated is...

Страница 10: ...uirements in accordance with Standard DIN EN 62368 1 have to be taken into account General Safety instructions The building in equipment has been evaluated for use in office environment pollution degr...

Страница 11: ...ounding strap on the wrist when working with such assemblies which you attach to an unpainted non conductive metal part of the system Use only tools and devices that are free from static electricity T...

Страница 12: ...only Replacing the Lithium Battery The life time of the lithium battery on the receiver boards is at least 10 years If the need arises to replace the battery the following should be noted There is a D...

Страница 13: ...ters by a second bracket included in the scope of delivery 4 2 Device Manufacturer Meinberg Funkuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 23...

Страница 14: ...Authorization RMA number for shipping You can also request the RMA number from our website https www meinbergglobal com english support rma htm The device must be packed in its original packaging or s...

Страница 15: ...5 Front Connectors TCR180PEX EL 5 Front Connectors TCR180PEX EL 1 RxD TxD GND 2 TCR180PEX EL FO 3 2 3 1 4 TCR180PEX EL Date 6th May 2021 11...

Страница 16: ...pter Pre setting standard and multiref port for the pin assignment 5 2 Time Code Fiber Optic Input Input signal Time code DCLS pulse width modulated e g IRIG B00x Input type Fiber Optic FO Multimode T...

Страница 17: ...operating temperature LED 2 green TCR180PEX EL receives a valid time code at the input red TCR180PEX EL does not receive a valid time code at the input yellow TCR180PEX EL is synchronized to a multi r...

Страница 18: ...Most of the commonly used IRIG code formats also don t provide an indicator whether the transported time is UTC or local time with some offset from UTC However the TCR180PEX EL always needs to derive...

Страница 19: ...ght saving is the first sunday after March 25th at two o clock MESZ End of daylight saving is the first sunday after October 25th at three o clock MEZ The parameters for time zone and switching to fro...

Страница 20: ...el Shift no carrier BCD time of year complete date SBS time of day output level adjusted IEEE 1344 Code according to IEEE 1344 1995 100 pps DC Level Shift no carrier BCD time of year SBS time of day I...

Страница 21: ...with a higher amplitude are used an additional external series resistance has to be applied to not exceed the limit of the forward current of the input diode 60 mA The forward current should not be l...

Страница 22: ...detected at one of these inputs the microprocessor stores the number of the input and the current time in a buffer memory which can hold up to 500 entries The capture events can be displayed using the...

Страница 23: ...tem for shipping damage If the system is damaged or cannot be put into operation contact Meinberg immediately Only the recipient the person or company receiving the system can assert a claim against f...

Страница 24: ...ock must be switched to ON before installing the TCR180PEX EL The table below shows the pin assignment of the connector and the assignment of the individual switches in the DIP 1 block At delivery of...

Страница 25: ...S out RS232 8 2 RxD 0 in RS232 3 TxD 0 out RS232 4 PPO_1 PPM out TTL 5 4 10 MHz out TTL 10 5 GND 6 CAP 0 in TTL 2 7 CAP 1 in TTL 3 7 DCLS out B RS422 7 8 PPO_0 PPS out TTL 4 9 PPO_2 DCF out TTL 9 9 DC...

Страница 26: ...The default settings of the pulse outputs of the TCR180PEX EL are set as follows PO_0 PPS Out Pulse Per Second PO_1 PPM Out Pulse Per Minute 22 Date 6th May 2021 TCR180PEX EL...

Страница 27: ...6 7 8 9 10 ON DIP 1 block DIP 2 block DIP 1 2 3 4 5 6 7 8 9 10 ON DIP OFF ON Switch position Pin 1 DIP 1 or DIP 7 ON Pin 4 DIP 5 or DIP 10 ON The graphic shows all DIP switches on position OFF Please...

Страница 28: ...settings from the BIOS 7 4 1 Installation of slotcards For protection of the TCR180PEX EL refer to the chapter Prevention of ESD Damage 1 Pay attention to the safety instructions at the beginning of...

Страница 29: ...function of TCR180PEX EL the date stored in the realtime clock of the board must be set when using IRIG codes therefore This setting can be done by a terminal software also If the time zone of the rec...

Страница 30: ...the new firmware from one of the computer s serial ports to the clock s serial port COM0 The bootstrap loader does not depend on the contents of the flash memory so if the update procedure is interrup...

Страница 31: ...b connector insulated by photocoupler internal series resistance 220 maximum forward current 60 mA diode vorward voltage 1 0 V 1 3 V Decoding Decoding of the following telegrams possible IRIG A002 A00...

Страница 32: ...ON Computime SPA RACAL Capture inputs Triggered by falling TTL slope pulse repetition time 1 5 msec min resolution 800 nsec output of trigger event via PCI bus or serial interface Master Oszillator TC...

Страница 33: ...ce compatible to PCI Express specification r1 0a Data format binary byte serial Power supply 3 3 V DC 250 mA 10 mA Power supplies provided by PCI Express interface Board dimension low profile slot car...

Страница 34: ...used for the correlation of data The definition of time code formats was completely arbitrary and left to the individual ideas of each design engineer Hundreds of different time codes were formed som...

Страница 35: ...11 Technical appendix TCR180PEX EL 11 2 Time code Format 11 2 1 IRIG Standard Format TCR180PEX EL Date 6th May 2021 31...

Страница 36: ...11 2 2 AFNOR Standard Format 32 Date 6th May 2021 TCR180PEX EL...

Страница 37: ...0 while leap second uv clock status characters depending on clock type u GPS clock is running free without exact synchr PZF time frame not synchronized DCF77 clock has not synchronized after reset spa...

Страница 38: ...ther characters are part of the time string The groups of characters as defined below x 0 or 1 corresponding on the number of the capture input _ ASCII space 20h dd mm yy the capture date dd day of mo...

Страница 39: ...offset of local timezone related to UTC in hours and minutes ac clock status characters a clock has not synchronized after reset space 20h clock has synchronized after reset c GPS receiver has not che...

Страница 40: ...replaced by a space character 20h e longitude the following characters are possible E east of Greenwich W west of Greenwich hhhh altitude above WGS84 ellipsoid in meters leading signs are replaced by...

Страница 41: ...month 01 12 yy year of the century 00 99 w the day of the week 1 7 1 Monday hh mm ss the current time hh hours 00 23 mm minutes 00 59 ss seconds 00 59 or 60 while leap second xxxx time zone indicator...

Страница 42: ...rs whereas the other characters are part of the time string The groups of characters as defined below T Start character sending with one bit accuracy at change of second yy mm dd the current date yy y...

Страница 43: ...s whereas the other characters are part of the time string The groups of characters as defined below jj mm tt the current date jj year of the century 00 99 mm month 01 12 tt day of month 01 31 _ Space...

Страница 44: ...numbers whereas the other characters are part of the time string The groups of characters as defined below X Control character code 58h sending with one bit accuracy at change of second G Control char...

Страница 45: ...lics are replaced by ASCII numbers whereas the other characters are part of the time string The groups of characters as defined below SOH Start of Header ASCII control character sending with one bit a...

Страница 46: ...ng and one wire pair for receiving data TX Logic D Component A Component B D VBIAS VBIAS D D RX Logic RX Logic TX Logic This design leads to a full duplex connection clocked with 2 5 GHz capable of tr...

Страница 47: ...monitor software MBGMON This utility can be used to configure Meinberg re ceivers via their serial ports and to display status information of the module If the USB storage device is lost the installa...

Страница 48: ...minated biphenyls PBBs and polybrominated diphenyl ethers PBDEs Bis 2 ethylhexyl phthalat DEHP Benzylbutylphthalat BBP Dibutylphthalat DBP Diisobutylphthalat DIBP above the legal threshold WEEE status...

Страница 49: ...tion auf das sich diese Erkl rung bezieht mit den folgenden Normen und Richtlinien bereinstimmt to which this declaration relates is in conformity with the following standards and provisions of the di...