12 Technical appendix TCR180
12.4 RS-232 COMx
Connector:
D-SUB male 9pol.
Cable:
shielded data line
Assignment:
Pin 2:
RxD (receive)
Pin 3:
TxD (transmit)
Pin 5:
GND (ground)
COM x
1
6
9
5
12.5 Time Code AM Input
Isolation voltage:
3000 V DC
impedance (input):
std. 600 Ohm,
(50 Ohm / 5 kOhm)
Signal range:
ca.600 mV - 8 V
(Mark, peak-peak)
Connector:
BNC female, isolated
Cable:
shielded coax line
TC AM In
WARNING!
This equipment is operated at a hazardous voltage.
Danger to life due to electrical shock!
- Never work with open terminals and plugs while the power is on!
- When working on the connectors, always remove both sides of the
cable from the respective devices!
- The device is equipped with potential-free and isolated connections.
In the event of a fault in a connected device, dangerous voltages can
occur at the signal lines.