The wiring is explained in the following drawing. The connection of the slave clocks
occurs via the rear VG connector. The correct polarity of the connected slave clocks
can be checked by comparing the NUC80E slave line time with the time displayed on
the slave clocks. If the slave clocks are one second/minute past or ahead the correspon-
ding line must be connected to the NUC80E with reverse polarity.