Meinberg LANTIME M600 Скачать руководство пользователя страница 2

Содержание LANTIME M600

Страница 1: ...TECHNICAL REFERENCE LANTIME M600 GPS NTP Time Server with GPS Receiver 5th April 2018 Meinberg Radio Clocks GmbH Co KG...

Страница 2: ......

Страница 3: ...Timestring 8 6 3 Error Relay 9 6 4 GPS Antenna 9 6 5 Time Code AM Output 10 6 6 Time Code DCLS Output 10 6 7 Pulse Per Second Output 10 6 8 10MHz Output 10 6 9 Synthesizer for frequencies 11 6 10 Puls...

Страница 4: ...g Funkuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 2014 10 10 LANTIME M600...

Страница 5: ...The building in equipment has been evaluated for use in office environment pollution degree 2 and may be only used in this environment For use in rooms with a higher pollution degree more stringent r...

Страница 6: ...l 5 Vorsicht Risiko eines elektrischen Schlages Caution possibility of electric shock 6 ISO 7000 0434 Vorsicht Risiko einer Gefahr Caution Danger 7 2012 19 EU Dieses Produkt f llt unter die B2B Katego...

Страница 7: ...well as a combination of these references hybrid system External references are also possible The LANTIME system is a set of equipment composed of an integrated GPS receiver a single board com puter a...

Страница 8: ...ons LANTIME Chassis Protection Rating IP20 Power Consumption Base configuration 30 W max 50 W depending on the integrated module options Ambient Temperature 0 50 C Storage Temperature 20 70 C Humidity...

Страница 9: ...ating mode of the reference clock reference time is shown Instead of GPS NORMAL OPERATION the messages GPS COLD BOOT GPS WARM BOOT or GPS UPDATE ALMANAC can appear as GPS reference Time In case the an...

Страница 10: ...on it is possible to configure the parameters with a terminal program To establish a connection between the LANTIME and a PC use a NULL MODEM cable Configure your terminal pro gram with 38400 Baud 8 D...

Страница 11: ...M ETH3 ETH2 8 6 10 6 1 Power Connector Input Voltage Range 100 240 V AC 50 60Hz Input Current 0 65 Amax Input Fuse UL IEC127 250 V AC S 3 15 A Connector input IEC320 AC inlet O I 100 240 V 50 60 Hz 6...

Страница 12: ...ng Current max 1A Switching Load max DC 30 W AC 60 VA Switching Current UL CSA 0 46 A 140 V AC 0 46 A 65 V DC 1A 30 V DC Response Time ca 2ms Normal Operation Mode Normal Operation CO NO connected CO...

Страница 13: ...ime Code DCLS Output Signal outputs DCLS TTL high or low active Connector BNC female Cable shielded coax line TC DCLS Out 6 7 Pulse Per Second Output Level TTL 2 5 V into 50 Ohm Connector BNC female C...

Страница 14: ...e TTL F Synth Out 6 10 Pulse Per Minute Output Level TTL into 50 Ohm Connector BNC female Cable shielded coax line Pulse length 200 ms PPM Out 6 11 10 100base T Ethernet IEEE 803 2 Link Speed 10 100 M...

Страница 15: ...G58 coaxial cable should be used to connect the antenna downconverter unit to the receiver The maximum length of cable between antenna and receiver depends on the attenuation factor of the coaxial cab...

Страница 16: ...mounting bracket Normally you connect the antenna converter directly with the antenna cable to the system GPS Antenna free view to the sky Cable Slot N Norm female N Norm male N Norm male N Norm femal...

Страница 17: ...following message appears in the display ANTENNA SHORT CIRCUIT DISCONNECT POWER If this message appears the clock has to be disconnected from the mains and the defect eliminated After that the clock c...

Страница 18: ...mercury hexavalent chromium polybrominated biphenyls PBBs and polybrominated diphenyl ethers PBDEs above the legal threshold WEEE status of the product This product is handled as a B2B Business to Bus...

Страница 19: ...s of measurement of Immunity characteristics of information technology equipment EN 60950 1 2006 Safety of information technology equipment A11 2009 A1 2010 A12 2011 AC 2011 A2 2013 EN 50581 2012 Tech...