background image

Connecting Data Cables
During a thunderstorm, data transmission lines must not be connected or disconnected (risk of
lightning).

When wiring the devices, the cables must be connected or disconnected in the order of the
arrangement described in the user documentation accompanying the device. Always attach all cables
to the plug during connection and removal. Never pull the cable itself. Pulling the cable can cause
the cables to disconnect from the plug.

Install the cables in way that they do not constitute a hazard (danger of tripping) and are not
damaged, i.e. kinked.

Connecting Power Supply
This equipment is operated at a hazardous voltage. Non-observance of the safety instructions in this
manual may result in serious personal injury or property damage.

Before connecting to the power supply, a grounding cable must be connected to the earth connection
of the device.

Before operation, check that all cables and lines work properly and are undamaged. Pay particular
attention to the facts that the cables do not have kinks or that they are not too short around corners,
and no objects are placed on the cables. Also make sure that all connections are secure.

Faulty shielding or cabling will endanger your health (electrical shock) and may destroy other
equipment.

Ensure that all necessary safety precautions have been taken. Make all connections to a unit before
turning on the power. Observe the safety instructions on the device (see safety symbols).

The metal housing of the device is grounded. It must be ensured that enough air and creepage
distances to neighboring voltage-carrying parts are provided during assembly in the control cabinet
and no short circuits are caused.

In the case of malfunctions or servicing (e.g. in the event of a damaged housing or power cable or
when fluids or foreign objects enter), the current flow can be interrupted. Questions about the
house installation, need to be clarified with your house administration.

The power supply should be connected with a short, low-inductance line.

6

Date: 1st March 2021

LANTIME M200/GPS

Содержание LANTIME M200/GPS

Страница 1: ...TECHNICAL REFERENCE LANTIME M200 GPS NTP Time Server with GPS Receiver 1st March 2021 Meinberg Funkuhren GmbH Co KG...

Страница 2: ......

Страница 3: ...S 13 4 Technical Specifications LANTIME Chassis 14 5 LANTIME M200 Front Connectors 16 6 LANTIME M200 Rear Connectors 18 6 1 AC Power Connector 18 6 2 10 100BASE T Network Port IEEE 803 2 19 6 3 USB Po...

Страница 4: ...g Funkuhren GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Internet https www meinbergglobal com Mail info meinberg de Date 01 03 2021 LANTIME M200...

Страница 5: ...y only continue if you have understood and fulfilled all requirements In this documentation dangers and indications are classified and illustrated as follows DANGER The signal word indicates an immine...

Страница 6: ...eines elektrischen Schlages Caution risk of electric shock IEC 60417 5041 Vorsicht hei e Oberfl che Caution hot surface IEC 60417 6056 Vorsicht Gef hrlich sich bewegende Teile Caution moving fan blad...

Страница 7: ...used for the purpose described in this manual In particular the given limits of the device must be observed The safety of the installation in which the unit is integrated is the responsibility of the...

Страница 8: ...ing additional measures e g Installation in an air conditioned control cabinet required Transport Unpacking Installation If the unit is brought into the operating room from a cold environment condensa...

Страница 9: ...properly and are undamaged Pay particular attention to the facts that the cables do not have kinks or that they are not too short around corners and no objects are placed on the cables Also make sure...

Страница 10: ...the mains socket on the appliance or the mains socket of the house installation is freely accessible to the user so that the mains cable can be pulled out of the socket in case of emergency Outside th...

Страница 11: ...conductor via the protective earth connection terminal If an external earth connection is provided on the housing it must be connected to the equipotential bonding rail grounding rail The mounting pa...

Страница 12: ...alled and when the doors are closed cooling fire protection shielding against electrical magnetic and electromagnetic fields Switch off in fault service case By switching off the devices are not disco...

Страница 13: ...surfaces If necessary switch off the unit before installing or removing any equipment and allow it to cool down 2 7 Handling Batteries CAUTION The lithium battery on the receiver modules has a service...

Страница 14: ...ruction Prepare removal and installation of assemblies Unload yourself for example by touching a grounded object before touching assemblies Ensure that you wear a grounding strap on the wrist when wor...

Страница 15: ...e product symbol on the left indicates that this electronic product must not be disposed of in domestic waste Return and Collection Systems For returning your old equipment please use the country spec...

Страница 16: ...ceiver GNS UC only GPS and Galileo an IRIG time code receiver or a long wave receiver DCF77 MSF WWVB as well as external NTP servers or a DCF77 GNSS combination as hybrid receiver can be used as refer...

Страница 17: ...ial sheet steel Temperature range Operation 0 50 C 32 122 F Storage 20 70 C 4 158 F Relative humidity Operation max 85 non condensing at 30 C Maximum altitude Operation max 4000 m 13123 ft above sea l...

Страница 18: ...Ground Connection on the Housing This connector must be wired to an equipotential bonding bar earthing bar Connection is possible on both sides of the housing The mounting parts without cable are inc...

Страница 19: ...of GPS NORMAL OPERATION the messages GPS COLD BOOT GPS WARM BOOT or GPS UPDATE ALMANAC can appear In case the antenna connection is interrupted the following message is shown GPS ANTENNA FAULTY GPS NO...

Страница 20: ...ervice green NTP is synchronized to the reference clock e g GPS180 red NTP is not synchronized or switched to the local clock Network green all monitored network interfaces are connected Link up red a...

Страница 21: ...ower Pmax 30 W Max heat emission Etherm 108 00 kJ h 102 37 BTU h O I 100 240 V 50 60 Hz WARNING This equipment is operated at a hazardous voltage Danger to life due to electrical shock Only qualified...

Страница 22: ...6 4 Terminal To connect a serial terminal according to the device model use the RJ45 connector of the LAN CPU Via the serial terminal connection it is possible to con figure parameters with a command...

Страница 23: ...terfaces is faulty Time Service green NTP is synchronized to the reference clock e g GPS180 red NTP is not synchronized or switched to the local clock Ref Time green the reference clock e g build in G...

Страница 24: ...Output voltage 15 V 100 mA via antenna cable Connection type BNC female N standard female Cable type shielded coax Cable length max 300 m to RG58 max 700 m to RG213 Antenna GNSS IF 15 V BNC N Norm N t...

Страница 25: ...on resp no antenna connected or short circuit on the antenna line green antenna connected and clock is synchronized Nav green positioning complete Init blue initialisation phase green warmed up oscill...

Страница 26: ...election of the Antenna location To receive enough satellites select a location that allows an unobstructed view of the sky otherwise there may be problems with the synchronization of the system There...

Страница 27: ...sed by lightning strikes can be transmitted via the antenna cable and may cause damage to the receiver The receiver is pro tected against these effects by using the MBG S PRO surge protection Being in...

Страница 28: ...to the socket of the surge protection Earth cable to PE rail Cable circa 1 5 mm attached to the surge protection as short as possible 4 The next step is to connect the supplied coaxial cable between...

Страница 29: ...te the signal propagation time of the antenna cable therefore you need to enter the length of the antenna cable in meters or the compensation time in nanoseconds into the settings of your receiver Ant...

Страница 30: ...8 Technical Appendix GPS Antenna Accessories 8 Technical Appendix GPS Antenna Accessories Physical Dimensions LANTIME M200 GPS Date 1st March 2021 27...

Страница 31: ...MHz Frequencies Mixed frequency 10 MHz IF frequency 35 4 MHz Connector N Norm female connector Form factor ABS plastic case for outdoor installation Protection class IP66 Humidity 95 Temperature rang...

Страница 32: ...values can be found in the data sheet of the cable used 8 2 Antenna Short Circuit Only for assembly groups with front display In case of an antenna line short circuit the following message appears in...

Страница 33: ...ped with two type N female connectors It has no dedicated input output polarity or prefered mounting orientation Phoenix CN UB 280DC BB Features High RF Performance Multiple Strike Capability 20 kA Su...

Страница 34: ...in a 50 system typ 1 1 2 GHz Permissible HF power Pmax at VSWR xx 50 ohm system 700 W VSWR 1 1 200 W VSWR Capacity Core Earth typ 1 5 pF asymmetrical shield typ 1 5 pF Surge current resistance conduc...

Страница 35: ...8 3 1 MBG S PRO Physical Dimensions 67 11 15 8 25 13 4 8 3 2 Installation and Grounding 32 Date 1st March 2021 LANTIME M200 GPS...

Страница 36: ...lybrominated biphenyls PBBs and polybrominated diphenyl ethers PBDEs Bis 2 ethylhexyl phthalat DEHP Benzylbutylphthalat BBP Dibutylphthalat DBP Diisobutylphthalat DIBP above the legal threshold WEEE s...

Страница 37: ...einstimmt to which this declaration relates is in conformity with the following standards and provisions of the directives RED Richtlinie ETSI EN 303 413 V1 1 1 2017 06 RED Directive 2014 53 EU EMV Ri...

Отзывы: