background image

5.2 Black Out Output

Output Signal:

NTSC (525i @ 59.94 Hz)

"Black & Burst" ITU-R BT.1700/
SMPTE 170M

PAL (625i @ 50 Hz)

"Black & Burst", ITU-R BT.1700

720p @ 50 Hz

Tri-Level Sync, SMPTE 296M

1080i @ 50 Hz

Tri-Level Sync, SMPTE 274M

720p @ 59.94 Hz

Tri-Level Sync, SMPTE 296M

1080i @ 59.94 Hz

Tri-Level-Sync, SMPTE 274M

PAL & NTSC signals can include embedded VITC

SMPTE 12M-1/SMPTE 309M

Signal Level:

300 mV

pp

,

75

termination (unbalanced)

Connector Type:

BNC Connector, Female

Cable:

Coaxial Cable, Shielded

5.3 DARS Output (Unbalanced)

Output Signal:

DARS (Unbalanced)

Signal Level:

TTL, 2.5 V

pp

,

75

termination

Signal Type:

Digital audio with sample rate of
44.1 kHz or 48 kHz

Connector Type:

BNC Connector, Female

Cable:

Coaxial Cable, Shielded

10

Date: March 2, 2022

IMS-VSG181H

Содержание IMS-VSG181H

Страница 1: ...SETUP GUIDE IMS VSG181H Hot Plug Module March 2 2022 Meinberg Funkuhren GmbH Co KG...

Страница 2: ......

Страница 3: ...Balanced 12 5 4 3 Word Clock Output 12 6 Before You Start 13 6 1 Contents of Delivery 13 6 2 Disposal of Packaging Materials 13 7 System Installation 14 7 1 Important Information Regarding Hot Plugga...

Страница 4: ...en GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Website https www meinbergglobal com Email info meinberg de Date February 23 2022 Manual Version...

Страница 5: ...nge log troubleshooting chapter minor corrections 1 1 2 23 2022 Corrections to frame rate support via LTC output adjustments to Web Interface following firmware updates new screenshots clarification o...

Страница 6: ...ronized against an external reference frequency 10 MHz a pulse per second sig nal PPS and a time string from an upstream clock These synchronization signals are essential to maintaining the precision...

Страница 7: ...efore setting up the device for use This device may only be used for the purpose described in this manual In particular the specified operat ing limits of the device must be heeded The person setting...

Страница 8: ...urn be attached to an uncoated non conductive metal part of the system Use only tools and devices that are free of static electricity When transporting devices Devices must only be touched or held by...

Страница 9: ...disconnec tion from the mains supply In the event that a power supply unit is no longer working e g defective please return it to Meinberg for repair Failure to observe these safety instructions may...

Страница 10: ...81H Module Connectors and Indicators 5 IMS VSG181H Module Connectors and Indicators 1 2 3 4 The numbering in the drawing above relates to the relevant subsection in this chapter IMS VSG181H Date March...

Страница 11: ...signal LED A Status of Black Out output LED B Status of LTC output St In A B The status LEDs A and B only provide information about whether the outputs have been enabled and properly configured in th...

Страница 12: ...ack Out signal Yellow flashing Adjusting timing pattern of Black Out signal module oscillator is not yet warmed up Green not flashing Output enabled module oscillator is warmed up timing is being fine...

Страница 13: ...ri Level Sync SMPTE 274M PAL NTSC signals can include embedded VITC SMPTE 12M 1 SMPTE 309M Signal Level 300 mVpp 75 termination unbalanced Connector Type BNC Connector Female Cable Coaxial Cable Shiel...

Страница 14: ...unction Pin 1 LTC Pin 2 LTC Pin 3 Not connected Pin 4 Not connected Pin 5 Not connected Pin 6 GND Pin 7 GND Pin 8 GND Pin 9 GND Pin 10 GND Pin 11 DARS Pin 12 DARS Pin 13 Word Clock 2 5 V 75 Pin 14 Not...

Страница 15: ...t Signal DARS Balanced Signal Level TTL 2 5 Vpp 110 termination pin 11 and 12 Signal Type Sample frequencies 44 1 kHz and 48 kHz 5 4 3 Word Clock Output Output Signal Word Clock Signal Level TTL 2 5 V...

Страница 16: ...please contact Meinberg immediately Only the recipient the person or company receiving the system may file claims or complaints against the forwarder for damage caused in transit Meinberg recommends...

Страница 17: ...lacing it in order to keep your system on I O ESI and MRI Slots Hot Pluggable CLK1 CLK2 Hot Pluggable When a clock module is replaced or installed it is important to rescan Slots the reference clocks...

Страница 18: ...The module must be pulled carefully out of the guide rail Note that the module will be securely seated in the connector block inside the chassis a certain amount of force must be applied to release t...

Страница 19: ...and unbalanced LTC DARS and word clock signals can be read from the device via the 15 pin D Sub connector for which a suitable cable must be specifically assembled The cable should be fitted with a 15...

Страница 20: ...tup of a IMS VSG181H using the Web Interface The IMS VSG181H is configured by selecting the menu I O Config Output Configuration in the Web Interface The configuration options addressed in this chapte...

Страница 21: ...st ITU R BT 1700 SMPTE ST 170 2004 PAL 625i 50 Hz Black Burst ITU R BT 1700 720p 50 Hz Tri Level Sync SMPTE ST 296 1080i 50 Hz Tri Level Sync SMPTE ST 274 720p 59 94 Hz Tri Level Sync SMPTE ST 296 108...

Страница 22: ...rated 6 22 Daily Jam Time Define a time for the daily jam event Use Local Time If the IMS LANTIME server is being operated as a PTP Offset from PTP slave enabling this option will cause the IMS VSG181...

Страница 23: ...gnal Type OFF DARS 48 kHz DARS 44 1 kHz Label You can use this field to define a custom label for the output or you can leave the field blank Please note Output 4 is a follower port whose output is so...

Страница 24: ...on is enabled the module will format the date information According to integrated into the LTC data in accordance with the format specified ITU R BR 1353 in the ITU recommendation BR 1353 If it is dis...

Страница 25: ...tate Disabled Enabled Base Frequency 44 1 kHz 48 kHz Scale Used to set the factor by which the base frequency sampling rate will be multiplied by The frequency of the output signal is thus calculated...

Страница 26: ...8 Configuration and Setup via Web Interface 8 5 Misc Time Zone This can be used to set the time zone of the IMS VSG181H module IMS VSG181H Date March 2 2022 23...

Страница 27: ...MS device s firmware may Using the instructions in the chapter not be up to date Firmware Updates in your IMS device manual check whether the latest version of LANTIME OS is installed and install the...

Страница 28: ...ormation for configuration and status monitoring Be a part of the ongoing improvement of the information contained in this manual Please contact our Technical Support team if you have any suggestions...

Страница 29: ...minated biphenyls PBBs polybrominated diphenyl ethers PBDEs bis 2 ethylhexyl phthalat DEHP benzyl butyl phthalate BBP dibutyl phthalate DBP or diisobutyl phthalate DIBP above the legal limits WEEE sta...

Страница 30: ...ve GND Ground HD High definition LTC Linear Time Code alternately Longitudinal Time Code LTOS LANTIME Operating System NTSC National Television Standard Committee NTP Network Time Protocol PAL Phase A...

Отзывы: