Meinberg IMS-VSG181 Скачать руководство пользователя страница 1

SETUP GUIDE

IMS-VSG181

Hot-Plug Module

March 1, 2022

Meinberg Funkuhren GmbH & Co. KG

Содержание IMS-VSG181

Страница 1: ...SETUP GUIDE IMS VSG181 Hot Plug Module March 1 2022 Meinberg Funkuhren GmbH Co KG...

Страница 2: ......

Страница 3: ...11 6 Before You Start 12 6 1 Contents of Delivery 12 6 2 Disposal of Packaging Materials 12 7 System Installation 13 7 1 Important Information Regarding Hot Pluggable IMS Modules 13 7 2 Installation o...

Страница 4: ...en GmbH Co KG Lange Wand 9 31812 Bad Pyrmont Germany Phone 49 0 52 81 93 09 0 Fax 49 0 52 81 93 09 230 Website https www meinbergglobal com Email info meinberg de Date February 23 2022 Manual Version...

Страница 5: ...resentation of specifications new troubleshooting section list of abbreviations system compatibility list updates to safety chapter overhaul of web interface chapter to reflect new features 1 11 2 23...

Страница 6: ...n upstream clock These synchronization signals are essential to maintaining the precision of the output signals The Web Interface provides a wide range of adjustment and customization options for all...

Страница 7: ...before setting up the device for use This device may only be used for the purpose described in this manual In particular the specified operat ing limits of the device must be heeded The person setting...

Страница 8: ...urn be attached to an uncoated non conductive metal part of the system Use only tools and devices that are free of static electricity When transporting devices Devices must only be touched or held by...

Страница 9: ...disconnec tion from the mains supply In the event that a power supply unit is no longer working e g defective please return it to Meinberg for repair Failure to observe these safety instructions may...

Страница 10: ...181 Module Connectors and Indicators 5 IMS VSG181 Module Connectors and Indicators 1 2 3 4 5 The numbering in the drawing above relates to the relevant subsection in this chapter IMS VSG181 Date March...

Страница 11: ...signal LED A Status of Black Out output LED B Status of LTC output St In A B The status LEDs A and B only provide information about whether the outputs have been enabled and properly configured in th...

Страница 12: ...Out signal Yellow flashing Adjusting timing pattern of Black Out signal module oscillator is not yet warmed up Green not flashing Output enabled module oscillator is warmed up timing is being fine tu...

Страница 13: ...TSC signals can include embedded VITC SMPTE ST 12M 1 SMPTE ST 309M Signal Level 300 mVpp 75 termination unbalanced Connector Type BNC Connector Female Cable Coaxial Cable Shielded 5 3 LTC Output Outpu...

Страница 14: ...ord Clock Output Output Signal Word Clock Signal Level TTL 2 5 Vpp 75 termination Frequency Range 24 Hz 12 288 MHz Sample Frequencies 44 1 kHz and 48 kHz Scale Factors At sample frequency 44 1 kHz 1 3...

Страница 15: ...ntact Meinberg immediately Only the recipient the person or company receiving the system may file claims or complaints against the forwarder for damage caused in transit Meinberg recommends that you k...

Страница 16: ...oving or replacing it in order to keep your system on I O ESI and MRI Slots Hot Pluggable CLK1 CLK2 Hot Pluggable When a clock module is replaced or installed it is important to rescan Slots the refer...

Страница 17: ...e must be pulled carefully out of the guide rail Note that the module will be securely seated in the connector block inside the chassis a certain amount of force must be applied to release the module...

Страница 18: ...signal a digital DARS signal a digital LTC signal and a digital word clock signal The signal outputs should be connected to your receiver device using coaxial cable with the proper char acteristic im...

Страница 19: ...using the Web Interface The IMS VSG181 is configured by selecting the menu I O Config Output Configuration in the Web In terface The configuration options addressed in this chapter represent a IMS VSG...

Страница 20: ...525i 59 94 Hz Black Burst ITU R BT 1700 SMPTE ST 170M PAL 625i 50 Hz Black Burst ITU R BT 1700 720p 50 Hz Tri Level Sync SMPTE ST 296 1080i 50 Hz Tri Level Sync SMPTE ST 274M 720p 59 94 Hz Tri Level S...

Страница 21: ...to be integrated 6 22 Daily Jam Time Set a time for the Daily Jam event Use Local Time If the IMS LANTIME server is being operated as a PTP Offset from PTP slave enabling this option will cause the I...

Страница 22: ...tion is enabled the module will format the date information According to integrated into the LTC data in accordance with the format specified ITU R BR 1353 in ITU Recommendation BR 1353 If it is disab...

Страница 23: ...Digital Audio Out Digital Audio Reference Signal DARS Signal Type OFF DARS 48 kHz DARS 44 1 kHz Label You can use this field to define a custom label for the output or you can leave the field blank 20...

Страница 24: ...Frequency 44 1 kHz 48 kHz Scale Used to set the factor by which the base frequency is multiplied by The frequency of the output signal is thus calculated as Base Frequency Scale Factor Output Frequenc...

Страница 25: ...8 5 Misc Time Zone This can be used to set the time zone for the IMS VSG181 module 22 Date March 1 2022 IMS VSG181...

Страница 26: ...ight Your IMS device s firmware may Using the instructions in the chapter not be up to date Firmware Updates in your IMS device manual check whether the latest version of LANTIME OS is installed and i...

Страница 27: ...nfiguration and status monitoring Be a part of the ongoing improvement of the information contained in this manual Please contact our Technical Support team if you have any suggestions for improvement...

Страница 28: ...m polybrominated biphenyls PBBs polybrominated diphenyl ethers PBDEs bis 2 ethylhexyl phthalat DEHP benzyl butyl phthalate BBP dibutyl phthalate DBP or diisobutyl phthalate DIBP above the legal limits...

Страница 29: ...finition LTC Linear Time Code alternatively Longitudinal Time Code LTOS LANTIME Operating System NTSC National Television Standard Committee NTP Network Time Protocol PAL Phase Alternating Line RSC Re...

Отзывы: