5.4.7 Assignment of the DIP Switch
SDI-4112, SDI-4505 und SDI-5302, SDI-7312 Modules
The monitoring of the input signals can be set with the DIP switch block.
Operating Modes
If the switches (e.g. 1 - 5 from DIP 10pin.) are ON, all inputs of the module will be monitored. If, for ex-
ample, no IRIG time code is connected via the assigned BNC female connector, the switches 2 and 3 should be
set to position OFF, otherwise the LED 3 indicates a fault status.
ON
DIP
Switch Signal
LED
if "ON"
——————————————————————————–
1 :
Error
LED 3 + 4
(flashes red)
2 :
TC-AM
LED 3
(red)
3 :
TC-DCLS
LED 3
(red)
4 :
10 MHz
LED 4
(red)
5 :
PPS
LED 4
(red)
DIP-switch SDI7312
ON
1 2 3 4
ON
1 2 3 4
A
B
Switch Signal
LED
if "ON"
——————————————————————————–
A1 :
Error
LED 3 + 4
(flashed red)
A2 :
TC-AM
LED 3
(red)
A3 :
TC-DCLS
LED 3
(red)
A4 :
10 MHz
LED 4
(red)
B1 :
PPS
LED 4
(red)
B2 :
PP
LED 4
(red)
B3 :
2048kHz
LED 3
(red)
B4 :
serial
LED 4
(red)
Hints for LIU Telecom Modules:
If only LIU modules (T1 / E1 Telecom output signals) are used in an IMS MDU chassis, only the 10MHz input
must be connected to the SDI input module. Correspondingly, the DIP switch block needs to be set "on": Switch
1 and 4 (DIP 10pol.) or switch A1 and A4 (DIP 4pol.).