![Meinberg IMS LANTIME M1000 Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/meinberg/ims-lantime-m1000/ims-lantime-m1000_manual_1766244056.webp)
LED Indicators
Init
blue:
while the receiver passes through
the initialization phase
green:
the oscillator has warmed up
Nav.
green:
positioning successfully
Ant
red:
antenna faulty or not connected
yellow:
the clock is synchronized by an external
Signal - MRS mode (PPS, IRIG ...)
Fail
red:
time has not synchronized
Pin Assignment of the DSUB9 Connectors (male):
Pin 2: RxD
Pin 3: TxD
Pin 5: GND
Synchronization with PPS + string:
Pin 1: PPS
Pin 2: String
*
*
The following timestrings (time telegrams) can be
used:
NMEA RMC
NMEA ZDA
Meinberg Standard
Uni Erlangen
COM
Pin Assignment of the optional XHE-SPI Connectors:
A1: PPS In
A2: PPS Out
Pin 1: SCL_Out (SPI Clock)
Pin 2: CS (Chip Select)
Pin 3: MOSI (Master Out, Slave In)
Pin 4: MISO (Master In, Slave Out)
Pin 5: GND
Attention:
Use this plug only to connect a MEIN-
BERG IMS-XHE
Rb
Rubidium expansion chassis.