background image

10

Copying the distributed Software to the Hard Disk

When the computer has come up after power on the utility programs should be copied
from the shipped diskette to a subdirectory on the hard disk. Assume the current drive
is C: and the new subdirectory is to be created on the current drive, create that
subdirectory (e.g. called MEINBERG) using the command

MD \MEINBERG

from the DOS command line. Make the new subdirectory the current one using the
command

CD \MEINBERG

If the utility diskette is inserted in drive A: use the following command to copy the
files and subdirectories from the diskette to the hard disk:

XCOPY A:*.*  /S

Using PCPSINFO.EXE

After the board has been installed in the computer the program PCPSINFO.EXE
should be run in order to see if the board has been properly installed. This program can
display its messages in English or in German language and the date and time in
formats used in the USA, the UK, or Germany. The default language and formats used
are derived from the DOS country code at startup. If automatic language detection
does not yield the desired result, you can force a language and date/time format using
a command line parameter or by pressing a function key when the program is running.
The command syntax is shown below:

PCPSINFO [C:xx] [MONO] [?]

Usage of the command line parameters is described below:

C:xx

Country code override. The default country code to be used is derived from the COUN-
TRY=.... entry in the CONFIG.SYS file.

xx may be set to 49 (Germany, 24h clock, dd.mm.yy), 44 (U.K, 12h clock, dd/mm/yy)
or 1 (USA, 12h clock, mm-dd-yy).

Содержание DCF77 PCI32

Страница 1: ...Technical Information Operating Instructions FUNKUHREN DCF77 PCI32...

Страница 2: ...Impressum Werner Meinberg Auf der Landwehr 22 D 31812 Bad Pyrmont Phone 49 52 81 9309 0 Fax 49 52 81 9309 30 Internet http www meinberg de Email info meinberg de May 18 1998...

Страница 3: ...ing the PCI32 in your Computer 8 Files on the Diskette shipped with the Board 9 Support for other Operating Systems 9 Copying the distributed Software to the Hard Disk 10 Using PCPSINFO EXE 10 The res...

Страница 4: ...4 Driver Diskette for DOS Windows...

Страница 5: ...l as some parity and status bits can be decoded from the time marks of the 15th up to the 58th second every minute The absence of any time mark at the 59th second of a minute signals that a new minute...

Страница 6: ...s to the board is made via writing to reading from I O ports It is possible but not necessary to let the board generate periodic hardware interrupts on the computer bus Utility programs supplied with...

Страница 7: ...e time marks and synchronizing All information given by these LEDs can also be obtained from the screen of the program PCPSINFO EXE The 9 pin sub D connector is wired to the radio clock s serial port...

Страница 8: ...reserved 7 P_SEC out RS 232 3 8 P_SEC out TTL 4 9 reserved The signals which have no lever of the DIL switch assigned are hard wired to the pins of the connector All levers of the DIL switch which ar...

Страница 9: ...usly the board s status PCPSDRV COM resident driver keeps computer time synchronized with board time DRV EXE temporarily disables the resident driver DISP EXE enables or disables the permanent date ti...

Страница 10: ...d in the computer the program PCPSINFO EXE should be run in order to see if the board has been properly installed This program can display its messages in English or in German language and the date an...

Страница 11: ...driver and the last recent date time the driver has read from the board The number of the user interrupt is determined automatically when the resident driver is installed It is not affected by the ha...

Страница 12: ...need arise The board s current state is shown in the field Status The first line shows whether the clock has ever been synchronized with DCF77 since the last power up or board reset If there are tran...

Страница 13: ...ll modify the computer s time just after being installed In the default case the computer s system time will only be modified when the clock has synchronized at least once after power up Status Synchr...

Страница 14: ...d line parameters DRV EXE temporarily disables the resident driver s access to the board Command DRV ON or DRV OFF Default enabled DISP EXE enables or disables the date time window on the screen Comma...

Страница 15: ...MECODE CHECK Parity and consistency checking over a period of two minutes RF distortions indicated by both LED and a bit of the status register Without RF signal the clock runs on XTAL with an accurac...

Страница 16: ...8N1 7E2 8N2 or 8E1 Mode of Operation send string per second per minute after request received Output String Meinberg standard time string described below POWER REQUIREMENT 5V 80mA PHYSICAL DIMENSION...

Страница 17: ...of inadequate replacement of the lithium battery Only identical batteries or batteries recommended by the manufacturer must be used for replacement The waste battery must be disposed as pro posed by...

Страница 18: ...hours 00 23 mm minutes 00 59 ss seconds 00 59 or 60 while leap second uv clock status characters u clock has not synchronized after reset space 20h clock has synchronized after reset v different for D...

Страница 19: ...19 PCI32 Component Layout...

Страница 20: ......