2 Important Safety Information
AC Power Supply
DC Power Supply
•
The device is a Protection Class 1 device and
may only be connected to a grounded outlet
(TN system).
•
For safe operation, the installation must be
protected by a fuse of a rating not exceeding
16 A and equipped with a residual-current
circuit breaker in accordance with applicable
national standards.
•
The disconnection of the appliance from the
mains power supply must always be performed
from the mains socket and not from the
appliance itself.
•
Mains-powered appliances are equipped with
a safety-tested mains cable designed for use
in the country of operation and may only be
connected to a grounded shockproof socket,
otherwise electric shock may occur.
•
Make sure that the mains socket on the
appliance or the mains socket of the house
installation is readily accessible for the user
so that the mains cable can be pulled out of
the socket in an emergency.
•
In accordance with IEC 62368-1, it must be
possible to disconnect the appliance from the
supply voltage from a point other than the
appliance itself (e.g., from the primary circuit
breaker).
•
The power supply plug may only be fitted or
dismantled while the appliance is isolated
from the power supply (e.g., disconnected at
the primary circuit breaker).
•
Supply cables must be adequately secured
and have an adequate wire gauge size.
Connection Cable Wire Gauge:
1 mm
2
–
2.5 mm
2
17 AWG
–
13 AWG
•
The power supply of the device must have a
suitable disconnection mechanism such as a
switch. This disconnection mechanism must
be readily accessible in the vicinity of the
appliance and marked accordingly as a cut-
off mechanism for the appliance.
Converter
Date: November 19, 2021
7
Содержание CON/FO/TTL-4/DHS