3 Technical Specications C600RS
3.11.2 Passive Output to Active Input
If a current loop output shall be wired to operate as passive output, the input must be wired to operate as an
active input. A connection from the pin lpass_in to Vcc (+5V) must be provided. The pin labeled
-act_in is pulled down to the auxiliary -15V supply, which must be made available by the user.
If an extermal -15V supply is not available, the -act_out signal can be connected directly to GND, as shown
below: